Background: Currently available antiarrhythmic drugs (AADs) for the prevention of atrial fibrillation (AF)/atrial flutter (AFL) suffer from incomplete efficacy and poor tolerability.
Hypothesis: Dronedarone could represent an effective and safe option in patients previously treated with AADs, especially class Ic AADs and sotalol.
Methods: Retrospective analysis of 2 double-blind, parallel-group trials (EURIDIS [European Trial in Atrial Fibrillation or Flutter Patients Receiving Dronedarone for the Maintenance of Sinus Rhythm] and ADONIS [American-Australian-African Trial With Dronedarone in Atrial Fibrillation or Flutter Patients for the Maintenance of Sinus Rhythm]) comparing the efficacy and safety of dronedarone with placebo over 12 months.
Introduction: Celivarone, a new noniodinated benzofuran derivative pharmacologically related to dronedarone and amiodarone, has been shown to have antiarrhythmic properties at a molecular level. The purpose of the 2 trials presented here (MAIA and CORYFEE) was to assess celivarone efficacy in the maintenance of sinus rhythm postcardioversion and for the conversion of atrial fibrillation (AF)/atrial flutter (AFL).
Methods And Results: In the MAIA trial, 673 patients with AF/AFL recently converted to sinus rhythm were randomly assigned to receive 50, 100, 200, or 300 mg once-daily dosing of celivarone; 200 mg daily of amiodarone preceded by a loading dose of 600 mg for 10 days; or placebo.
Background: Celivarone is a new antiarrhythmic agent developed for the treatment of ventricular arrhythmias. This study investigated the efficacy and safety of celivarone in preventing implantable cardioverter-defibrillator (ICD) interventions or death.
Methods And Results: Celivarone (50, 100, or 300 mg/d) was assessed compared with placebo in this randomized, double-blind, placebo-controlled, parallel-group study.
Background: Implantable cardioverter-defibrillators (ICDs) remain the treatment of choice for the prevention of life-threatening arrhythmias. However, many patients with ICDs require additional antiarrhythmic therapy to reduce the morbidity associated with recurrent arrhythmia-triggered ICD interventions.
Objective: Our study aimed to evaluate the safety and efficacy of celivarone in reducing these interventions.
Background: Amiodarone is effective in maintaining sinus rhythm in atrial fibrillation but is associated with potentially serious toxic effects. Dronedarone is a new antiarrhythmic agent pharmacologically related to amiodarone but developed to reduce the risk of side effects.
Methods: In two identical multicenter, double-blind, randomized trials, one conducted in Europe (ClinicalTrials.