Purpose: To describe the outcome and comorbidities of ocular tics in children evaluated by a pediatric neuro-ophthalmologist.
Methods: The medical records of all consecutive patients in a pediatric neuro-ophthalmology practice diagnosed with ocular tics (eye rolling, blinking, and widening) were retrospectively reviewed. Children with known secondary causes for tics were excluded.
Optical coherence tomography (OCT) derived retinal measures, particularly peri-papillary retinal nerve fiber layer (RNFL) thickness, have been proposed as outcome measures in remyelinating and neuroprotective trials in multiple sclerosis (MS). With increasing utilization of multiple centers to improve power, elucidation of the impact of different OCT technologies is crucial to the design and interpretation of such studies. In this study, we assessed relation and agreement between RNFL thickness and total macular volume (in MS and healthy controls) derived from three commonly used OCT devices: Stratus time-domain OCT, and Cirrus HD-OCT and Spectralis, two spectral-domain (SD) OCT devices.
View Article and Find Full Text PDFObjective: Cross-sectional studies of optical coherence tomography (OCT) show that retinal nerve fiber layer (RNFL) thickness is reduced in multiple sclerosis (MS) and correlates with visual function. We determined how longitudinal changes in RNFL thickness relate to visual loss. We also examined patterns of RNFL thinning over time in MS eyes with and without a prior history of acute optic neuritis (ON).
View Article and Find Full Text PDF