Publications by authors named "Estevam Bonfante"

Objectives: This study aimed to elucidate the effect of various two-step sintering (TSS) protocols on the physical, mechanical, and optical properties of partially stabilized zirconia with different yttria dopant concentrations (Y-PSZ).

Methods: Disc-shaped specimens were obtained from most widely used commercial dental zirconia powders of various Y contents (Tosoh Corp.) by uniaxial pressing followed by cold-isostatic pressing.

View Article and Find Full Text PDF

The objective was to evaluate the effect of material (four monolithic zirconia) and surface condition [glazed (G) versus polished after simulation of occlusal adjustment (GAP)] on roughness and volumetric wear (VW) of dental zirconia after chewing simulation (CS). Zirconia specimens (ZS) were fabricated with an approximate diameter of 12.0 mm and a thickness of 1.

View Article and Find Full Text PDF

Osseodensification is a novel approach that has significantly advanced the field of implant dentistry, particularly in the context of transcrestal maxillary sinus floor elevation. This technique involves the use of specially designed burs that compact and densify bone along the osteotomy walls, thereby enhancing implant primary stability and facilitating osseointegration in low-density bone. This article reviews the historical evolution of implant site preparation, and the biomechanical, histological, and clinical evidence of osseodensification with a special focus on its application in sinus floor augmentation.

View Article and Find Full Text PDF
Article Synopsis
  • Osseodensification enhances the stability of endosteal implants but doesn't consider the limited trabecular bone found in clinical situations.
  • This study involved surgical experiments on twelve sheep, comparing osteotomy healing with and without trabecular bone, using osseodensification drilling to place implants.
  • Results showed enhanced bone formation and remodeling in the group with trabecular bone, with significant increases in bone-to-implant contact and bone area occupancy at both 3 and 12 weeks; there were no negative effects noted in the absence of trabecular bone.
View Article and Find Full Text PDF

Purpose: This multicenter cross-sectional clinical study aimed to evaluate the membrane perforation rate during transcrestal sinus floor elevation (TSFE) using osseodensification (OD) burs and assess risk factors associated with the procedure.

Materials And Methods: This study was conducted in six centers, following ethical standards and approved by local committees. It included patients over 18 years old missing maxillary posterior teeth with crestal residual bone height (RBH) ≥2 and ≤6 mm.

View Article and Find Full Text PDF

Placing dental implants in microvascular bone free flaps used for reconstructing the mandible or maxilla has been previously reported. However, there is scarce information available on the restorative protocol using short dental implants placed in a (DCIA) microvascular free flap and the rationale behind it. This case report describes a 18-year-old patient referred to the hospital for numbness and dull pain of the left mandible, which she observed for three months.

View Article and Find Full Text PDF

Objectives: To assess the effects of different aging protocols on chemical, physical, and mechanical properties of an experimental ATZ composite compared to a zirconia.

Methods: Disc-shaped specimens were obtained through uniaxial pressing of commercial powders (Tosoh), ATZ comprised of 80%ZrO/20%AlO (TZ-3YS20AB) and 3Y-TZP (3Y-SBE). The specimens of each material were divided into different groups according to the aging protocol: immediate, autoclave aging and hydrothermal reactor aging.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the 10-year outcomes of partial fixed dental prostheses (P-FDPs) fabricated using metal-free fiber-reinforced composite (FRC) resin frameworks veneered with composite resin and supported by short and extra-short implants.

Methods: This study included 28 patients with 38 FRC prostheses supported by 96 implants. Implant and prosthesis survival and success rates were evaluated using Kaplan-Meier analysis.

View Article and Find Full Text PDF

Objective: This cohort study aimed to assess the incidence of somatosensory alterations after implant surgery using standardized quantitative and qualitative sensory testing.

Methods: 33 participants with single-tooth loss, undergoing immediate implant loading were included. Quantitative Sensory Testing (QST) and Qualitative Sensory Testing (QualST) were conducted at eight time points over a year (baseline to 1 year).

View Article and Find Full Text PDF

Objectives: To investigate vitamin-D levels effect on the survival/success and on marginal bone levels of dental implants.

Methods: Patients with peri-implant disease and healthy control patients with functionally loaded dental implants were included in this retrospective case-control study. Forty patients with 201 implants were in the diseased-cohort, while thirty-three patients with 90 implants were in the control-cohort.

View Article and Find Full Text PDF

A technique is outlined for utilising a polymeric composite reinforced with glass fibres in a three-dimensional mesh as a post-core in aesthetic cases. The clinical procedure involves obtaining an impression of the root canal space, scanning the definitive cast, and milling a fibre-reinforced composite post-core. Subsequently, the intra-radicular post-core is cemented using an adhesive resin cement.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates how the strength of temporary dental restorations is affected by thermal aging, focusing on different resin-based materials.
  • It involves testing 192 resin specimens made from various materials under thermal cycling conditions to assess their flexibility and strength.
  • Results show that the type of resin material and the thermal aging process significantly influence their strength, with Filtek Bulk-Fill performing better than J-Temp and Fuji Lining.
View Article and Find Full Text PDF

There is limited information regarding implant and prosthetic survival after osseous microvascular free flap (OMFF). This case series aims to describe the placement of short and extra short implants in osseous microvascular free flaps to support prostheses, and present an up to 40-month retrospective follow-up. Short and extra short dental implants were placed in six fibula free flaps (FFF) and in two microvascular deep circumflex iliac artery (DCIA) flaps.

View Article and Find Full Text PDF

The present work aims to develop a production method of pre-sintered zirconia-toughened-alumina (ZTA) composite blocks for machining in a computer-aided design and computer-aided manufacturing (CAD-CAM) system. The ZTA composite comprised of 80% AlO and 20% ZrO was synthesized, uniaxially and isostatically pressed to generate machinable CAD-CAM blocks. Fourteen green-body blocks were prepared and pre-sintered at 1000 °C.

View Article and Find Full Text PDF

To develop a peri-implantitis model in a Gottingen minipig and evaluate the effect of local application of salicylic acid poly(anhydride-ester) (SAPAE) on peri-implantitis progression in healthy, metabolic syndrome (MS), and type-2 diabetes mellitus (T2DM) subjects. Eighteen animals were allocated to three groups: (i) control, (ii) MS (diet for obesity induction), and (iii) T2DM (diet plus streptozotocin for T2DM induction). Maxillary and mandible premolars and first molar were extracted.

View Article and Find Full Text PDF

Purpose: This retrospective study evaluated the effect of selected clinical and patient factors on survival, success, and peri-implant bone level changes of locking taper implants supporting molar crowns on Bicon's prefabricated shouldered abutments.

Methods: A total of 234 patients, who received 274 single molar crowns supported by locking taper implants were included in this retrospective study. Kaplan-Meier survival analysis was used to assess overall implant survival, prostheses survival, and success.

View Article and Find Full Text PDF

This in vivo study evaluated the bone healing response around endosteal implants with varying surface topography/chemistry in a preclinical, large transitional model induced with metabolic syndrome (MS) and type-2 diabetes mellitus (T2DM). Fifteen Göttingen minipigs were randomly distributed into two groups: (i) control (normal diet, n = 5) and (ii) O/MS (cafeteria diet for obesity induction, n = 10). Following obesity induction, five minipigs from the obese/metabolic syndrome (O/MS) group were further allocated, randomly, into the third experimental group: (iii) T2DM (cafeteria diet + streptozotocin).

View Article and Find Full Text PDF

Purpose: The aim of this study was to establish and assess the validity of in silico models of biaxial flexural strength (BFS) tests to reflect in vitro physical properties obtained from two commercially available computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic blocks and one CAD/CAM resin composite block.

Methods: In vitro three-point bending and BFS tests were conducted for three CAD/CAM materials (n = 10): Katana Zirconia ST10 (raw material: super-translucent multilayered zirconia, ST10; Kuraray Noritake Dental, Niigata, Japan), Katana Zirconia HT10 (raw material: highly translucent multilayered zirconia, HT10; Kuraray Noritake Dental), and Katana Avencia N (AN; Kuraray Noritake Dental). Densities, flexural moduli, and fracture strains were obtained from the in vitro three-point bending test and used as an input for an in silico nonlinear finite element analysis.

View Article and Find Full Text PDF

Dental zirconias have been broadly utilized in dentistry due to their high mechanical properties and biocompatibility. Although initially introduced in dentistry as an infrastructure material, the high rate of technical complications related to veneered porcelain has led to significant efforts to improve the optical properties of dental zirconias, allowing for its monolithic indication. Modifications in the composition, processing methods/parameters, and the increase in the yttrium content and cubic phase have been presented as viable options to improve zirconias' translucency.

View Article and Find Full Text PDF

This study aimed to develop a recycling process for the remnants of milled 3Y-TZP and enhance their properties using glass infiltration. 3Y-TZP powder was gathered from the vacuum system of CAD-CAM milling equipment, calcined and sieved (x < 75 μm). One hundred twenty discs were fabricated and pre-sintered at 1000 °C/h.

View Article and Find Full Text PDF

The aim of this study was to evaluate the effect of two finishing techniques, glazing or polishing, in comparison with the as-cut condition, on the biaxial-flexural-strength (BFS) of a zirconia-reinforced lithium silicate ceramic (ZLS). Cylinders were milled from CAD/CAM blocks and sliced to obtain disc-shaped specimens (ISO6872:2015). Polished and glazed specimens were processed following the manufacturer's instructions.

View Article and Find Full Text PDF

To assess the influence of dentifrices with different abrasiveness levels on the properties of dental reconstructive materials. Forty-eight cylinders were obtained from four polymeric materials, being two CAD/CAM acrylic resins (Ivotion-Dent and Ivotion-Base), one injected acrylic resin (IvoBase-Hydrid) and one light-cured resin composite (Empress Direct). Specimens were allocated to four subgroups for toothbrushing simulation according to the dentifrice relative dentin abrasivity (RDA) and silica content: (i) RDA 0 = 0%; (ii) RDA 50 = 3%; (iii) RDA 100 = 10%; and (iv) RDA 120 = 25%.

View Article and Find Full Text PDF

Objectives: To process an alumina-toughened zirconia (ATZ) nanocomposite and to characterize its crystalline phases, microstructure, residual stress, mechanical and optical properties before and after two different artificial aging methodologies.

Methods: Disc-shaped specimens were obtained through uniaxial pressing of a commercial ATZ powder comprised of 80%ZrO / 20%AlO, with a particle size of 50 nm and 150 nm, respectively. Sintering was performed at 1500ºC for 2 h.

View Article and Find Full Text PDF

Objective: To evaluate the effect of different hydrofluoric acid concentrations and etching times on the surface, chemical composition and microstructure of lithium disilicate.

Material And Methods: Ninety specimens of pressed lithium disilicate (LDS) were obtained (IPS e.max Press, Rosetta SP and LiSi Press).

View Article and Find Full Text PDF

To assess the reliability and failure modes of Ti-base abutments supported by narrow and wide-diameter implant systems. Narrow (Ø3.5 × 10 mm) and wide (Ø5 × 10 mm) implant systems of two different manufacturers with internal conical connections (16°) and their respective Ti-base abutments (3.

View Article and Find Full Text PDF