Pharmaceutical effluents are complex media containing hundreds of compounds including active ingredients, intermediate products and unknown impurities. Bringing an industrial wastewater treatment plant (WWTP) into compliance with European directives requires a thorough analysis of the effluent. In this study, we demonstrate how online comprehensive two-dimensional liquid chromatography (on-line LC × LC) hyphenated to high resolution mass spectrometry (HRMS) can be a powerful analytical methodology to monitoring the outlet water, by analysing the content of known molecules while characterizing unknown compounds.