Background And Aims: Prophylactic implantable cardioverter-defibrillators (ICDs) are not recommended until left ventricular ejection fraction (LVEF) has been reassessed 40 to 90 days after an acute myocardial infarction. In the current therapeutic era, the prognosis of sustained ventricular arrhythmias (VAs) occurring during this early post-infarction phase (i.e.
View Article and Find Full Text PDFArch Cardiovasc Dis
September 2024
Background: Acute heart failure (AHF) is a leading cause of hospitalization and mortality - especially in patients aged≥65 years in high-income countries - and represents a high healthcare burden. In the past decade, the epidemiology and management of heart failure (HF) has changed, with the emergence of new medical and interventional therapeutics, but up-to-date real-life data are scarce.
Aims: The main objectives are to describe baseline characteristics (with an emphasis on lifestyle, cognitive status, HF knowledge and treatment adherence), management, and in-hospital and mid-term outcomes of AHF patients in France.
Background: Idiopathic ventricular fibrillation (IVF) can be associated with undetected distinct conditions such as microstructural cardiomyopathic alterations (MiCM) or Purkinje (Purk) activities with structurally normal hearts.
Objectives: This study sought to evaluate the characteristics of recurrent VF recorded on implantable defibrillator electrograms, associated with these substrates.
Methods: This was a multicenter collaboration study.
Background: Left atrial appendage closure (LAAC) for prevention of stroke is validated in patients with nonvalvular atrial fibrillation (NVAF) contraindicated to oral anticoagulation. General anaesthesia (GA) is often used for procedural guidance by transesophageal echocardiography (TEE); however, its use may be challenging in some patients. The aim of the study was to evaluate the safety and the midterm efficacy of a mini-invasive LAAC strategy using micro-TEE under procedural sedation.
View Article and Find Full Text PDFCardiac resynchronization therapy (CRT) is a recognized therapy for heart failure with altered ejection fraction and abnormal left ventricular activation time. Since the introduction of the therapy, a 30% rate of non-responders is observed and unchanged. The 12-lead ECG remains the only recommended tool for patient selection to CRT.
View Article and Find Full Text PDFBackground: Transcatheter aortic valve implantation is unfeasible for 10-15% of patients using the conventional transfemoral approach. Other alternative approaches, such as the subclavian approach, have emerged, with no clear recommendation indicating the superiority of one technique over another.
Aim: To compare the 1-month mortality and postprocedural outcomes of patients undergoing transcatheter aortic valve implantation using a self-expandable valve via transfemoral and subclavian access.
J Cardiovasc Dev Dis
October 2023
Background: Implantable cardioverter-defibrillators (ICDs) need to reliably detect ventricular tachycardia (VT) and ventricular fibrillation (VF) while avoiding T-wave oversensing (TWOS), which is associated with a risk of inappropriate therapies. The incidence of TWOS with endovascular ICDs appears to differ between manufacturers.
Objectives: We aimed to evaluate the incidence and clinical consequences of TWOS with contemporary Medtronic and Boston Scientific ICDs.
Objective: Left atrial appendage closure (LAAC) is recommended to decrease the stroke risk in patients with atrial fibrillation and contraindications to anticoagulation. However, age-stratified data are scarce. The aim of this study was to provide information on the safety and efficacy of LAAC, with emphasis on the oldest patients.
View Article and Find Full Text PDFAims: From a patient and health system perspective, managing worsening heart failure (WHF) as an outpatient has become a priority. Remote management allows early detection of WHF, enabling timely intervention with the aim of preventing hospitalization. The objective of the study was to evaluate the feasibility and safety of remotely managing WHF events using a multiparametric platform.
View Article and Find Full Text PDFBackground: Left atrial appendage occlusion (LAAO) procedures are widely guided by standard transesophageal echocardiography (TEE) probes, requiring general anesthesia in most patients. The use of miniaturized TEE probes allows for LAAO guidance under local anesthesia and offers an attractive imaging alternative to standard TEE probes.
Objectives: The aim of this study was to assess the safety and efficacy of miniaturized TEE probes for procedural guidance of LAAO.
Aims: Whether aldosterone levels after myocardial infarction (MI) are associated with mid- and long-term left ventricular (LV) remodelling in the era of systematic use of renin-angiotensin system inhibitors is uncertain. We prospectively investigated the relationship between aldosterone levels and mid- and long-term LV remodelling in patients with acute MI.
Methods And Results: Plasma aldosterone was measured in 119 patients successfully treated by primary percutaneous coronary angioplasty for a first acute ST-elevation MI (STEMI) 2-4 days after the acute event.
Background: Pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs) increasingly automatically record and remotely transmit nonsustained ventricular tachycardia (NSVT) episodes, which may reveal ventricular oversensing.
Objectives: We aimed to develop and validate a machine learning algorithm that accurately classifies NSVT episodes transmitted by PMs and ICDs in order to lighten health care workload burden and improve patient safety.
Methods: PMs or ICDs (Boston Scientific, St Paul, MN) from 4 French hospitals with ≥1 transmitted NSVT episode were split into 3 subgroups: training set, validation set, and test set.
Background: Fat layers in obese patients can impair R-wave detection and diagnostic performance of a subcutaneous insertable cardiac monitor (ICM). We compared safety and ICM sensing quality between obese patients [body mass index (BMI) ≥ 30 kg/m] and normal-weight controls (BMI <30 kg/m) in terms of R-wave amplitude and time in noise mode (noise burden) detected by a long-sensing-vector ICM.
Materials And Methods: Patients from two multicentre, non-randomized clinical registries are included in the present analysis on January 31, 2022 (data freeze), if the follow-up period was at least 90 days after ICM insertion, including daily remote monitoring.
Background: Insertable cardiac monitors (ICMs) are increasingly used for cardiac rhythm diagnosis with expanding indications. Little has been reported about their use and efficacy.
Objective: The study sought to evaluate the clinical utility of a novel ICM (Biotronik BIOMONITOR III) including the time to diagnosis in unselected patients with different ICM indications.
The impact that post-dilatation has on the risk of experiencing conduction disorders after post-transcatheter aortic valve replacement with self-expanding valves (SE-TAVR) is unclear. We compared the rate of developing an atrioventricular (AV) high-grade conduction disorder and permanent pacemaker implantation (PPI) in post-TAVR patients undergoing post-dilatation. We enrolled patients with severe symptomatic calcified aortic stenosis (CAS) who were undergoing SE-TAVR between 1 January 2016, and 19 April 2019 at a single French center.
View Article and Find Full Text PDFBackground: While prior Micra trials demonstrated a high implant success rate and favorable safety and efficacy results, changes in implant populations and safety over time is not well studied. The objective of this analysis was to report the performance of Micra in European and Middle Eastern patients and compare to the Micra Investigational Device Exemption (IDE) and Micra Post Approval Registry (PAR) studies.
Methods: The prospective, single-arm Micra Acute Performance European and Middle Eastern (MAP EMEA) registry was designed to further study the performance of Micra in patients from EMEA.
Background: New-onset left bundle branch block (LBBB) is one of the most frequent complications after transcatheter aortic valve implantation (TAVI) and is associated with delayed high degree atrioventricular (AV) block.
Objectives: The objectives of this study were to determine the incidence of AV block in such a population and to assess the performance and safety of a risk stratification algorithm on the basis of electrophysiology study (EPS) followed by implantation of a pacemaker or implantable loop recorder (ILR).
Methods: This was a prospective open-label study with 12-month follow-up.
Background: Magnesium (Mg) is often used to manage de novo atrial fibrillation (AF) in the emergency department (ED) and intensive care unit (ICU). Point of care measurement of ionized magnesium (iMg) allows a rapid identification of patients with impaired magnesium status, however, unlike ionized calcium, the interpretation of iMg is not entirely understood. Thus, we evaluated iMg reference values, correlation between iMg and plasmatic magnesium (pMg), and the impact of pH and albumin variations on iMg levels.
View Article and Find Full Text PDFAims: Leadless pacing has emerged as an alternative to conventional transvenous pacemakers to mitigate the risks of pocket- and lead-related complications but its use remains controversial in young adults mostly because experience in this patient population is limited. We sought to examine the feasibility and safety of implanting leadless single chamber pacemakers in young adults.
Methods: This multicenter, retrospective, observational study sought to evaluate the safety, efficacy, and electrical performance of the Micra VR Transcatheter Pacemaker System (Medtronic) in patients between 18 and 40 years who underwent implantation of a leadless pacemaker for any indication at the university medical centers of Bordeaux, Clermont-Ferrand, Toulouse, and Tours (France), between 2015 and 2021.