Publications by authors named "Ervin Nippolainen"

Vibrational spectroscopy methods such as mid-infrared (MIR), near-infrared (NIR), and Raman spectroscopies have been shown to have great potential for in vivo biomedical applications, such as arthroscopic evaluation of joint injuries and degeneration. Considering that these techniques provide complementary chemical information, in this study, we hypothesized that combining the MIR, NIR, and Raman data from human osteochondral samples can improve the detection of cartilage degradation. This study evaluated 272 osteochondral samples from 18 human knee joins, comprising both healthy and damaged tissue according to the reference Osteoarthritis Research Society International grading system.

View Article and Find Full Text PDF

Site-specific differences in the compressive properties of tibiofemoral joint articular cartilage are well-documented, while exploration of tensile and frictional properties in humans remains limited. Thus, this study aimed to characterize and compare the tensile, compressive and frictional properties of articular cartilage across different sites of the tibiofemoral joint, and to establish relationships between these properties and cartilage degeneration. We cut human tibiofemoral joint (N = 5) cartilage surfaces into tensile testing samples (n = 155) and osteochondral plugs (n = 40) to determine the tensile, friction and compressive properties, as well as OARSI grades.

View Article and Find Full Text PDF

Significance: Optical properties of biological tissues, such as refractive index (RI), are fundamental properties, intrinsically linked to the tissue's composition and structure. We hypothesize that, as the RI and the functional properties of articular cartilage (AC) are dependent on the tissue's structure and composition, the RI of AC is related to its biomechanical properties.

Aim: This study aims to investigate the relationship between RI of human AC and its biomechanical properties.

View Article and Find Full Text PDF

In order to improve the ability of clinical diagnosis to differentiate articular cartilage (AC) injury of different origins, this study explores the sensitivity of mid-infrared (MIR) spectroscopy for detecting structural, compositional, and functional changes in AC resulting from two injury types. Three grooves (two in parallel in the palmar-dorsal direction and one in the mediolateral direction) were made via arthrotomy in the AC of the radial facet of the third carpal bone (middle carpal joint) and of the intermediate carpal bone (the radiocarpal joint) of nine healthy adult female Shetland ponies (age = 6.8 ± 2.

View Article and Find Full Text PDF

Objective: The key characteristics of light propagation are the average penetration depth, average maximum penetration depth, average maximum lateral spread, and average path length of photons. These parameters depend on tissue optical properties and, thus, on the pathological state of the tissue. Hence, they could provide diagnostic information on tissue integrity.

View Article and Find Full Text PDF

Articular cartilage exhibits site-specific biomechanical properties. However, no study has comprehensively characterized site-specific cartilage properties from the same knee joints at different stages of osteoarthritis (OA). Cylindrical osteochondral explants (n = 381) were harvested from donor-matched lateral and medial tibia, lateral and medial femur, patella, and trochlea of cadaveric knees (N = 17).

View Article and Find Full Text PDF

Non-destructive assessments are required for the quality control of tissue-engineered constructs and the optimization of the tissue culture process. Near-infrared (NIR) spectroscopy coupled with machine learning (ML) provides a promising approach for such assessment. However, due to its nonspecific nature, each spectrum incorporates information on both neotissue and non-neotissue constituents of the construct; the effect of these constituents on the NIR-based assessments of tissue-engineered constructs has been overlooked in previous studies.

View Article and Find Full Text PDF

Significance: Articular cartilage exhibits a zonal architecture, comprising three distinct zones: superficial, middle, and deep. Collagen fibers, being the main solid constituent of articular cartilage, exhibit unique angular and size distribution in articular cartilage zones. There is a gap in knowledge on how the unique properties of collagen fibers across articular cartilage zones affect the scattering properties of the tissue.

View Article and Find Full Text PDF

Optical properties of biological tissues, such as refractive index, are fundamental properties, intrinsically linked to a tissue's composition and structure. This study aims to investigate the variation of refractive index (RI) of human articular cartilage along the tissue depth (via collagen fibril orientation and optical density) and integrity (based on Mankin and Osteoarthritis Research Society International (OARSI) scores). The results show the relationship between RI and PG content (=0.

View Article and Find Full Text PDF

Mid-infrared spectroscopy (MIR), near-infrared spectroscopy (NIR), and Raman spectroscopy are all well-established analytical techniques in biomedical applications. Since they provide complementary chemical information, we aimed to determine whether combining them amplifies their strengths and mitigates their weaknesses. This study investigates the feasibility of the fusion of MIR, NIR, and Raman spectroscopic data for characterising articular cartilage integrity.

View Article and Find Full Text PDF

There is increasing research on the potential application of diffuse optical spectroscopy and hyperspectral imaging for characterizing the health of the connective tissues, such as articular cartilage, during joint surgery. These optical techniques facilitate the rapid and objective diagnostic assessment of the tissue, thus providing unprecedented information toward optimal treatment strategy. Adaption of optical techniques for diagnostic assessment of musculoskeletal disorders, including osteoarthritis, requires precise determination of the optical properties of connective tissues such as articular cartilage.

View Article and Find Full Text PDF
Article Synopsis
  • The nitroglycerin (NTG) model is significant in migraine research, but its effects on intracranial vessels are not well understood.
  • This study investigated how NTG influences blood flow in meningeal vessels of rats using imaging photoplethysmography (iPPG), focusing on amplitude changes in the iPPG waveform.
  • Results showed that NTG caused varying effects on blood flow depending on pretreatment (saline vs. sumatriptan), indicating a complex interaction between NTG and blood vessel activity, with sumatriptan enhancing NTG's effects.
View Article and Find Full Text PDF

Osteoarthritis degenerates cartilage and impairs joint function. Early intervention opportunities are missed as current diagnostic methods are insensitive to early tissue degeneration. We investigated the capability of visible light-near-infrared spectroscopy (Vis-NIRS) to differentiate normal human cartilage from early osteoarthritic one.

View Article and Find Full Text PDF

Objective: To differentiate healthy from artificially degraded articular cartilage and estimate its structural, compositional, and functional properties using Raman spectroscopy (RS).

Design: Visually normal bovine patellae (n = 12) were used in this study. Osteochondral plugs (n = 60) were prepared and artificially degraded either enzymatically (via Collagenase D or Trypsin) or mechanically (via impact loading or surface abrasion) to induce mild to severe cartilage damage; additionally, control plugs were prepared (n = 12).

View Article and Find Full Text PDF

Injuries to the ligaments of the knee commonly impact vulnerable and physically active individuals. These injuries can lead to the development of degenerative diseases such as post-traumatic osteoarthritis (PTOA). Non-invasive optical modalities, such as infrared and Raman spectroscopy, provide means for quantitative evaluation of knee joint tissues and have been proposed as potential quantitative diagnostic tools for arthroscopy.

View Article and Find Full Text PDF

Preclassification of raw infrared spectra has often been neglected in scientific literature. Separating spectra of low spectral quality, due to low signal-to-noise ratio, presence of artifacts, and low analyte presence, is crucial for accurate model development. Furthermore, it is very important for sparse data, where it becomes challenging to visually inspect spectra of different natures.

View Article and Find Full Text PDF

The aim of the study was to optimize preprocessing of sparse infrared spectral data. The sparse data were obtained by reducing broadband Fourier transform infrared attenuated total reflectance spectra of bovine and human cartilage, as well as of simulated spectral data, comprising several thousand spectral variables into datasets comprising only seven spectral variables. Different preprocessing approaches were compared, including simple baseline correction and normalization procedures, and model-based preprocessing, such as multiplicative signal correction (MSC).

View Article and Find Full Text PDF

Optical properties of biological tissues in the NIR spectral range have demonstrated significant potential for in vivo diagnostic applications and are critical parameters for modelling light interaction in biological tissues. This study aims to investigate the optical properties of articular cartilage as a function of tissue depth and integrity. The results suggest consistent wavelength-dependent variation in optical properties between cartilage depth-wise zones, as well as between healthy and degenerated tissue.

View Article and Find Full Text PDF

Objective: Joint injuries may lead to degeneration of cartilage tissue and initiate development of posttraumatic osteoarthritis. Arthroscopic surgeries can be used to treat joint injuries, but arthroscopic evaluation of articular cartilage quality is subjective. Fourier transform infrared spectroscopy combined with fiber optics and attenuated total reflectance crystal could be used for the assessment of tissue quality during arthroscopy.

View Article and Find Full Text PDF

Near-infrared (NIR) spectroscopy is a powerful analytical method for rapid, non-destructive and label-free assessment of biological materials. Compared to mid-infrared spectroscopy, NIR spectroscopy excels in penetration depth, allowing intact biological tissue assessment, albeit at the cost of reduced molecular specificity. Furthermore, it is relatively safe compared to Raman spectroscopy, with no risk of laser-induced photothermal damage.

View Article and Find Full Text PDF

This study aimed to quantify the long-term progression of blunt and sharp cartilage defects and their effect on joint homeostasis and function of the equine carpus. In nine adult Shetland ponies, the cartilage in the radiocarpal and middle carpal joint of one front limb was grooved (blunt or sharp randomized). The ponies were subjected to an 8-week exercise protocol and euthanized at 39 weeks.

View Article and Find Full Text PDF

Absorption and reduced scattering coefficients ( ) of biological tissues have shown significant potential in biomedical applications. Thus, they are effective parameters for the characterization of tissue integrity and provide vital information on the health of biological tissues. This study investigates the potential of optical properties ( ) for estimating articular cartilage composition and biomechanical properties using multivariate and machine learning techniques.

View Article and Find Full Text PDF

This study evaluates the feasibility of near infrared (NIR) spectroscopy to distinguish between different cartilage injury types associated with post-traumatic osteoarthritis and idiopathic osteoarthritis (OA) induced by mechanical and enzymatic damages. Bovine osteochondral samples (n = 72) were subjected to mechanical (n = 24) and enzymatic (n = 36) damage; NIR spectral measurements were acquired from each sample before and after damage, and from a separate control group (n = 12). Biomechanical measurements were then conducted to determine the functional integrity of the samples.

View Article and Find Full Text PDF

Photoplethysmography (PPG) is a noninvasive optical method accepted in the clinical use for measurements of arterial oxygen saturation. It is widely believed that the light intensity after interaction with the biological tissue in vivo is modulated at the heartbeat frequency mainly due to pulsatile variations of the light absorption caused by arterial blood-volume pulsations. Here we report experimental observations, which are not consistent with this model and demonstrate the importance of elastic deformations of the capillary bed in the formation of the PPG waveform.

View Article and Find Full Text PDF

Blood pulsation imaging (BPI) is a non-invasive optical method based on photoplethysmography (PPG). It is used for the visualization of changes in the spatial distribution of blood in the microvascular bed. BPI specifically allows measurements of the relative phase of blood pulsations and using it we detected a novel type of PPG fast waveforms, which were observable in limited areas with asynchronous regional blood supply.

View Article and Find Full Text PDF