Proteomic measurements with greater throughput, sensitivity, and structural information are essential for improving both in-depth characterization of complex mixtures and targeted studies. While LC separation coupled with MS (LC-MS) measurements have provided information on thousands of proteins in different sample types, the introduction of a separation stage that provides further component resolution and rapid structural information has many benefits in proteomic analyses. Technical advances in ion transmission and data acquisition have made ion mobility separations an opportune technology to be easily and effectively incorporated into LC-MS proteomic measurements for enhancing their information content.
View Article and Find Full Text PDFRapid diagnosis of disease states using less invasive, safer, and more clinically acceptable approaches than presently employed is a crucial direction for the field of medicine. While MS-based proteomics approaches have attempted to meet these objectives, challenges such as the enormous dynamic range of protein concentrations in clinically relevant biofluid samples coupled with the need to address human biodiversity have slowed their employment. Herein, we report on the use of a new instrumental platform that addresses these challenges by coupling technical advances in rapid gas phase multiplexed ion mobility spectrometry separations with liquid chromatography and MS to dramatically increase measurement sensitivity and throughput, further enabling future high throughput MS-based clinical applications.
View Article and Find Full Text PDFThe utility of mass spectrometry (MS)-based proteomic analyses and their clinical applications have been increasingly recognized over the past decade due to their high sensitivity, specificity and throughput. MS-based proteomic measurements have been used in a wide range of biological and biomedical investigations, including analysis of cellular responses and disease-specific post-translational modifications. These studies greatly enhance our understanding of the complex and dynamic nature of the proteome in biology and disease.
View Article and Find Full Text PDFA high-throughput approach and platform using 15 min reversed-phase capillary liquid chromatography (RPLC) separations in conjunction with ion mobility spectrometry-mass spectrometry (IMS-MS) measurements was evaluated for the rapid analysis of complex proteomics samples. To test the separation quality of the short LC gradient, a sample was prepared by spiking 20 reference peptides at varying concentrations from 1 ng/mL to 10 microg/mL into a tryptic digest of mouse blood plasma and analyzed with both a LC-Linear Ion Trap Fourier Transform (FT) MS and LC-IMS-TOF MS. The LC-FT MS detected 13 out of the 20 spiked peptides that had concentrations >or=100 ng/mL.
View Article and Find Full Text PDFThe secondary structures of DNA hairpins, pseudoknots and cruciforms are of great interest because of their possible role in materials applications and biological functions such as regulating transcription. To determine the stability of these structures, DNA sequences capable of forming each were analyzed with mass spectrometry, ion mobility, and molecular dynamics calculations. Nano-ESI mass spectra indicated that stoichiometries compatible with hairpin, pseudoknot, and cruciform structures were present.
View Article and Find Full Text PDFG-rich DNA sequences are able to fold into structures called G-quadruplexes. To obtain general trends in the influence of loop length on the structure and stability of G-quadruplex structures, we studied oligodeoxynucleotides with random bases in the loops. Sequences studied are dGGGW(i)GGGW(j)GGGW(k)GGG, with W = thymine or adenine with equal probability, and i, j, and k comprised between 1 and 4.
View Article and Find Full Text PDFIon mobility spectrometry coupled with mass spectrometry (IMS-MS) was utilized to evaluate an ion collision energy ramping technique that simultaneously fragments a variety of species. To evaluate this technique, the fragmentation patterns of a mixture of ions ranging in mass, charge state, and drift time were analyzed to determine their optimal fragmentation conditions. The precursor ions were pulsed into the IMS-MS instrument and separated in the IMS drift cell based on mobility differences.
View Article and Find Full Text PDFThe ability of ion mobility spectrometry coupled with mass spectrometry (IMS-MS) to characterize biological mixtures has been illustrated over the past eight years. However, the challenges posed by the extreme complexity of many biological samples have demonstrated the need for higher resolution IMS-MS measurements. We have developed a higher resolution ESI-IMS-TOF MS by utilizing high-pressure electrodynamic ion funnels at both ends of the IMS drift cell and operating the drift cell at an elevated pressure compared with that conventionally used.
View Article and Find Full Text PDFB-DNA is the most common DNA helix conformation under physiological conditions. However, when the amount of water in a DNA solution is decreased, B-to-A helix transitions have been observed. To understand what type of helix conformations exist in a solvent-free environment, a series of poly d(CG)(n) and mixed sequence DNA duplexes from 18 to 30 bp were examined with circular dichroism (CD), ESI-MS, ion mobility, and molecular dynamics.
View Article and Find Full Text PDFIon mobility spectrometry (IMS) is increasingly employed to probe the structures of gas-phase ions, particularly those of proteins and other biological macromolecules. This process involves comparing measured mobilities to those computed for potential geometries, which requires evaluation of orientationally averaged cross sections using some approximate treatment of ion-buffer gas collisions. Two common models are the projection approximation (PA) and exact hard-spheres scattering (EHSS) that represent ions as collections of hard spheres.
View Article and Find Full Text PDFA promising approach for anticancer strategies is the stabilization of telomeric DNA into a G-quadruplex structure. To explore the intrinsic stabilization of folded G-quadruplexes, we combined electrospray ionization mass spectrometry, ion mobility spectrometry, and molecular modeling studies to study different DNA sequences known to form quadruplexes. Two telomeric DNA sequences of different lengths and two DNA sequences derived from the NHE III1 region of the c-myc oncogene (Pu22 and Pu27) were studied.
View Article and Find Full Text PDFThe metal binding properties of the dinucleotide duplex, dCG x dCG, were analyzed in the gas phase with ion mobility mass spectrometry. Both MALDI and ESI were used to generate [M(dCG x dCG)]+ complexes. The collision cross section of each complex was measured in helium using ion mobility based methods and compared to calculated cross sections of theoretical structures.
View Article and Find Full Text PDFThe ability of peptide nucleic acids (PNA) to form specific higher-order (i.e., three- and four-stranded) complexes with DNA makes it an ideal structural probe for designing strand-specific dsDNA biosensors.
View Article and Find Full Text PDFInhibiting the enzyme telomerase by stabilizing the G-quadruplex has potential in anticancer drug design. Diprotonated cyclo[n]pyrroles represent a set of expanded porphyrin analogues with structures similar to that of telomestatin, a natural product known to bind to and stabilize G-quadruplexes. As a first step toward testing whether cyclo[n]pyrroles display a similar function, a series of diprotonated cyclo[n]pyrroles (where n = 6, 7, and 8) was each added to the human telomere repeat sequence d(T(2)AG(3))(4) and examined with mass spectrometry, ion mobility, and molecular dynamics calculations.
View Article and Find Full Text PDFIon mobility mass spectrometry (IM-MS) was used to probe the structures of several metal complexes carrying pendant chromophores. The three complexes investigated were the copper(II) complex Cu(DAC)2+ (DAC = 1,8-bis(9-methylanthracyl)cyclam, cyclam = 1,4,8,11-tetraazacyclotetradecane), the N-nitrosylated ligand DAC-NO, and the Roussin's red salt ester (mu-S,mu-S')-protoporphyrin-IX-bis(2-thioethyl ester)tetranitrosyldiiron (PPIX-RSE). From the IM-MS data coupled with theoretical calculations, it was found that [Cu(II)(DAC - H)]+ exists as a single conformer, with one anthracenyl group above the cyclam and the other below, similar to the crystal structure of Cu(II)(DAC)2+.
View Article and Find Full Text PDFThe aggregation and conformation of deoxyguanosine (dG) in an ammonium acetate buffer solution were examined using mass spectrometry, ion mobility, and molecular mechanics/dynamics calculations. The nano-ESI mass spectrum indicated that 4 and 6 dGs cluster with 1 NH4+; 11 dGs with 2 NH4+; 14, 16, and 17 dGs with 3 NH4+; and 23 dGs with 4 NH4+. The collision cross sections with helium were measured and compared with calculated cross sections of theoretical structures generated by molecular mechanics/dynamics calculations.
View Article and Find Full Text PDFThe gas-phase conformations of a series of cytosine/guanine DNA duplexes were examined by ion mobility and molecular dynamics methods. Deprotonated duplex ions were formed by electrospray ionization, and their collision cross sections measured in helium were compared to calculated cross sections of theoretical models generated by molecular dynamics. The 4-mer (dCGCG) and 6-mer (dCGCGCG) duplexes were found to have globular conformations.
View Article and Find Full Text PDFtrans-1,2-Bis([2.2]paracyclophanyl)ethene (1) exists as a pair of diastereomers whose conformations, and thus effective collision cross sections, are quite different. The two forms can be obtained by different transition metal-catalyzed reactions.
View Article and Find Full Text PDF