Background: Shoulder arthroscopy is a safe and effective procedure with a low complication rate. Although rare, there are potentially life-threatening risks such as fluid extravasation causing airway compromise.
Case Presentation: We report the case of a 65-year-old female treated with an arthroscopic rotator cuff repair who had significant extravasation of arthroscopic fluid causing severe facial and neck swelling.