Pelizaeus-Merzbacher disease (PMD) is a hypomyelinating disorder caused by the duplication and missense mutations of the proteolipid protein 1 (PLP1) gene. PLP1 missense proteins accumulate in the endoplasmic reticulum (ER) of premature oligodendrocytes and induce severe ER stress followed by apoptosis of the cells. Here, we demonstrate that an anti-malaria drug, chloroquine, decreases the amount of an ER-resident mutant PLP1 containing an alanine-243 to valine (A243V) substitution, which induces severe PMD in human.
View Article and Find Full Text PDFMissense mutations in the proteolipid protein 1 (PLP1) gene cause a wide spectrum of hypomyelinating disorders, from mild spastic paraplegia type 2 to severe Pelizaeus-Merzbacher disease (PMD). Mutant PLP1 accumulates in the endoplasmic reticulum (ER) and induces ER stress. However, the link between the clinical severity of PMD and the cellular response induced by mutant PLP1 remains largely unknown.
View Article and Find Full Text PDFA cyanobacterium, semi-filamentous multicellular strain ABRG5-3, was isolated and its unique nature was characterized. This axenic strain formed colonies and was motile on an agarose plate. The 16S rRNA gene of ABRG5-3 exhibited similarities to those of the Limnothrix and Pseudanabaena strains, which are known as filamentous and nonheterocystous cyanobacteria.
View Article and Find Full Text PDFIn order to evaluate the usefulness of a metal oxide-silicon field-effect transistor (MOSFET) detector as a in vivo dosimeter, we performed in vivo dosimetry using the MOSFET detector with an anthropomorphic phantom. We used the RANDO phantom as an anthropomorphic phantom, and dose measurements were carried out in the abdominal, thoracic, and head and neck regions for simple square field sizes of 10 x 10, 5 x 5, and 3 x 3 cm(2) with a 6-MV photon beam. The dose measured by the MOSFET detector was verified by the dose calculations of the superposition (SP) algorithm in the XiO radiotherapy treatment-planning system.
View Article and Find Full Text PDFWe have developed a practical dose verification method for radiotherapy treatment planning systems by using only a Farmer ionization chamber in inhomogeneous phantoms. In particular, we compared experimental dose verifications of multi-layer phantom geometries and laterally inhomogeneous phantom geometries for homogeneous and inhomogenous dose calculations by using the fast-Fourier-transform convolution, fast-superposition, and superposition in the XiO radiotherapy treatment-planning system. We applied the dose verification method to three kernel-based algorithms in various phantom geometries with water-, lung- and bone-equivalent media of different field sizes.
View Article and Find Full Text PDFDosimetric characteristics of a metal oxide-silicon semiconductor field effect transistor (MOSFET) detector are studied with megavoltage photon beams for patient dose verification. The major advantages of this detector are its size, which makes it a point dosimeter, and its ease of use. In order to use the MOSFET detector for dose verification of intensity-modulated radiation therapy (IMRT) and in-vivo dosimetry for radiation therapy, we need to evaluate the dosimetric properties of the MOSFET detector.
View Article and Find Full Text PDFThe metal oxide semiconductor field-effect transistor (MOSFET) dosimeter has been widely studied for use as a dosimeter for patient dose verification. The major advantage of this detector is its size, which acts as a point dosimeter, and also its ease of use. The commercially available TN502RD MOSFET dosimeter manufactured by Thomson and Nielsen has never been used for proton dosimetry.
View Article and Find Full Text PDF