Publications by authors named "Erika Feller"

Following our previous experience with cardiac xenotransplantation of a genetically modified porcine heart into a live human, we sought to achieve improved results by selecting a healthier recipient and through more sensitive donor screening for potential zoonotic pathogens. Here we transplanted a 10-gene-edited pig heart into a 58-year-old man with progressive, debilitating inotrope-dependent heart failure due to ischemic cardiomyopathy who was not a candidate for standard advanced heart failure therapies. He was maintained on a costimulation (anti-CD40L, Tegoprubart) blockade-based immunomodulatory regimen.

View Article and Find Full Text PDF

Background: Proteomic phenotyping can provide insights into rejection pathophysiology, novel biomarkers, and therapeutic targets.

Methods: Within the prospective, multicenter Genomic Research Alliance for Transplantation study, 181 proteins were evaluated from blood drawn at the time of endomyocardial biopsy; protein fold change, logistic regression, and pathway analyses were conducted, with protein discovery adjusted for a 5% false discovery rate.

Results: Among 104 adult heart transplant patients (31% female sex, 53% Black race, median age 52 y), 74 had no rejection, 18 developed acute cellular rejection (ACR), and 12 developed antibody-mediated rejection (AMR).

View Article and Find Full Text PDF

Background: VAD therapy has revolutionized the treatment of end-stage heart failure, but infections remain an important complication. The objective of this study was to characterize the clinical and economic impacts of VAD-specific infections.

Methods: A retrospective analysis of a United States claims database identified members ≥ 18 years with a claim for a VAD implant procedure, at least 6 months of pre-implant baseline data, and 12 months of follow-up between 1 June 2016 and 31 December 2019.

View Article and Find Full Text PDF

Background: Noninvasive monitoring of heart allograft health is important to improve clinical outcomes. MicroRNAs (miRs) are promising biomarkers of cardiovascular disease and limited studies suggest they can be used to noninvasively diagnose acute heart transplant rejection.

Methods: The Genomic Research Alliance for Transplantation (GRAfT) is a multicenter prospective cohort study that phenotyped heart transplant patients from 5 mid-Atlantic centers.

View Article and Find Full Text PDF

Objectives: Six months after withdrawal of the HeartWare HVAD System (HVAD; Medtronic) from sale, approximately 4000 patients continue ongoing support with this device. In light of the diminishing experience, this global consensus document summarizes key management recommendations.

Methods: International experts with experience in the management of patients with ongoing HVAD support were invited to summarize key aspects of patient and pump management and highlight differences in the current HeartMate 3 (Abbott Laboratories) ventricular assist device.

View Article and Find Full Text PDF

Background: Left ventricular assist devices (LVADs) have been used as a standard treatment option for patients with advanced heart failure. However, these devices are prone to adverse events. Nonsurgical bleeding (NSB) is the most common complication in patients with continuous flow (CF) LVADs.

View Article and Find Full Text PDF

The Jarvik 2000 bridge to transplant investigational device exemption study was a multicentered, prospective study of 150 UNOS status I patients implanted with the Jarvik 2000 between 2005 and 2012. During the study period, there were numerous modifications of the system that included converting from pin to cone bearings. Results were analyzed for three cohorts: total (n = 150), pin (n = 128), and cone (n = 22).

View Article and Find Full Text PDF

The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device.

View Article and Find Full Text PDF

The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device.

View Article and Find Full Text PDF

The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device.

View Article and Find Full Text PDF

Black patients suffer higher rates of antibody-mediated rejection and have worse long-term graft survival after heart transplantation. Donor-derived cell free DNA (ddcfDNA) is released into the blood following allograft injury. This study analyzed %ddcfDNA in 63 heart transplant recipients categorized by Black and non-Black race, during the first 200 days after transplant.

View Article and Find Full Text PDF

The study aim was to examine the impact time in therapeutic range (TTR, International Normalized Ratio [INR] 2.0-3.0) has on survival and adverse events in patients receiving the HeartWare HVAD System in the ENDURANCE and ENDURANCE Supplemental Trials.

View Article and Find Full Text PDF

We previously reported low rates of pump thrombosis and hemorrhagic stroke, but increased bleeding, under our original antithrombosis protocol (P1) in HeartWare recipients. We designed and implemented a revised protocol (P2) to reduce complexity and bleeding. Thrombelastography and PFA-100 guide antiplatelet titration.

View Article and Find Full Text PDF

Significant residual mitral regurgitation (MR) after left ventricular assist device (LVAD) implantation has been associated with increased morbidity and mortality. The effect of cannula position on improvement of preexisting MR has yet to be evaluated. Consecutive patients who underwent centrifugal LVAD implantation with >mild preoperative MR and without concomitant mitral repair were reviewed.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effectiveness of using percent donor-derived cell-free DNA (%ddcfDNA) as a non-invasive biomarker for detecting acute rejection (AR) in heart transplant patients, compared to traditional endomyocardial biopsy (EMBx).
  • It involved 171 participants and found that %ddcfDNA levels significantly increased in cases of AR compared to controls, often indicating rejection earlier than EMBx could.
  • The results suggest that %ddcfDNA could potentially reduce the need for EMBx while maintaining a high negative predictive value, making it a promising tool for monitoring cardiac transplant health.
View Article and Find Full Text PDF

Objective: We have observed that minimally invasive left ventricular assist device (LVAD) insertion leads to more facile re-entry and easier cardiac transplantation. We hypothesize minimally invasive LVAD implantation results in improved outcomes at the time of subsequent heart transplant.

Methods: All adults undergoing cardiac transplantation between October 2015 and March 2019 at our institution were retrospectively reviewed.

View Article and Find Full Text PDF

A minimally invasive approach to left ventricular assist device (LVAD) insertion may benefit patients at the time of implant, but whether the approach to LVAD insertion influences the outcome of subsequent cardiovascular reoperations is unknown. Here we present the case of a 50-year-old male who underwent LVAD insertion through a minimally invasive approach and subsequently had left ventricular recovery. LVAD explant was performed without the use of any blood products or inotropic support.

View Article and Find Full Text PDF

Background: Despite improved survival and morbidity after durable left ventricular assist device (dLVAD), outcomes for cardiogenic shock patients are suboptimal. Temporary mechanical circulatory support (tMCS) can permit optimization before dLVAD. Excellent outcomes have been observed using minimally-invasive dLVAD implantation.

View Article and Find Full Text PDF

Clinical Trials in Organ Transplantation-18 (CTOT-18) is a follow-up analysis of the 200-subject multicenter heart transplant CTOT-05 cohort. CTOT-18 aimed to identify clinical, epidemiologic, and biologic markers associated with adverse clinical events past 1 year posttransplantation. We examined various candidate biomarkers including serum antibodies, angiogenic proteins, blood gene expression profiles, and T cell alloreactivity.

View Article and Find Full Text PDF

Objectives: The feasibility of F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) for the diagnosis of left ventricular assist device (LVAD) infection has been demonstrated. Beyond the diagnoses of LVAD infection, the authors hypothesized that the pattern and site of the infection along its various components may significantly impact clinical management and patient outcome.

Background: In patients with end-stage heart failure, the clinical use of LVAD for destination therapy is on the rise, accompanied by a higher prevalence of infections and serious complications.

View Article and Find Full Text PDF

There are no evidence-based guidelines for antithrombotic therapy in left ventricular assist device patients. We evaluated the efficacy of a multi-agent, test-guided protocol, which remained consistent throughout our use of the Heartware HVAD. Thrombelastography and platelet function analyzer (PFA)-100 guide antiplatelet titration.

View Article and Find Full Text PDF