Rechargeable magnesium batteries are promising for future energy storage. However, among other challenges, their practical application is hindered by low coulombic efficiencies of magnesium plating and stripping. Fundamental processes such as the formation, structure, and stability of passivation layers and the influence of different electrolyte components on them are still not fully understood.
View Article and Find Full Text PDFBackground: The topographic anatomical changes of the upper arms and axilla after massive weight loss (MWL) seem ill-described in the literature. The importance of the axilla in MWL brachioplasty and how the procedure differs from the postmenopausal "batwing" deformity of the upper arms is also unclear. Consideration of the underlying pathology seems imperative for a successful reconstruction.
View Article and Find Full Text PDFAdvanced aqueous batteries are promising solutions for grid energy storage. Compared with their organic counterparts, water-based electrolytes enable fast transport kinetics, high safety, low cost, and enhanced environmental sustainability. However, the presence of protons in the electrolyte, generated by the spontaneous ionization of water, may compete with the main charge-storage mechanism, trigger unwanted side reactions, and accelerate the deterioration of the cell performance.
View Article and Find Full Text PDFObjective: The proximal isovelocity surface area (PISA) method is a well-established approach for mitral regurgitation (MR) quantification. However, it exhibits high inter-observer variability and inaccuracies in cases of non-hemispherical flow convergence and non-holosystolic MR. To address this, we present EasyPISA, a framework for automated integrated PISA measurements taken directly from 2-D color-Doppler sequences.
View Article and Find Full Text PDFAims: To improve monitoring of cardiac function during major surgery and intensive care, we have developed a method for fully automatic estimation of mitral annular plane systolic excursion (auto-MAPSE) using deep learning in transoesophageal echocardiography (TOE). The aim of this study was a clinical validation of auto-MAPSE in patients with heart disease.
Methods And Results: TOE recordings were collected from 185 consecutive patients without selection on image quality.
Background: Continuous monitoring of mitral annular plane systolic excursion (MAPSE) using transesophageal echocardiography (TEE) may improve the evaluation of left ventricular (LV) function in postoperative intensive care patients. We aimed to assess the utility of continuous monitoring of LV function using TEE and artificial intelligence (autoMAPSE) in postoperative intensive care patients.
Methods: In this prospective observational study, we monitored 50 postoperative intensive care patients for 120 min immediately after cardiac surgery.
Rapid warming at high latitudes triggers poleward shifts of species' distributions that impact marine biodiversity. In the open sea, the documented redistributions of fish lead to a borealization of Arctic fauna. A climate-driven borealization and increased species diversity at high latitudes are also expected in coastal fish communities, but they have not been previously documented on a large, biogeographic scale.
View Article and Find Full Text PDFObjective: Evaluation of left ventricular (LV) function in critical care patients is useful for guidance of therapy and early detection of LV dysfunction, but the tools currently available are too time-consuming. To resolve this issue, we previously proposed a method for the continuous and automatic quantification of global LV function in critical care patients based on the detection and tracking of anatomical landmarks on transesophageal heart ultrasound. In the present study, our aim was to improve the performance of mitral annulus detection in transesophageal echocardiography (TEE).
View Article and Find Full Text PDFElectrolyte additives are indispensable to enhance the performance of Li-ion batteries. Lithium bis(oxalato)borate (LiBOB) has been explored for many years, as it improves both cathode and anode performance. No consensus regarding its reaction mechanisms has, however, been established.
View Article and Find Full Text PDFWe have developed a method to automatically assess LV function by measuring mitral annular plane systolic excursion (MAPSE) using artificial intelligence and transesophageal echocardiography (autoMAPSE). Our aim was to evaluate autoMAPSE as an automatic tool for rapid and quantitative assessment of LV function in critical care patients. In this retrospective study, we studied 40 critical care patients immediately after cardiac surgery.
View Article and Find Full Text PDFPurpose: Ilofotase alfa is a human recombinant alkaline phosphatase with reno-protective effects that showed improved survival and reduced Major Adverse Kidney Events by 90 days (MAKE90) in sepsis-associated acute kidney injury (SA-AKI) patients. REVIVAL, was a phase-3 trial conducted to confirm its efficacy and safety.
Methods: In this international double-blinded randomized-controlled trial, SA-AKI patients were enrolled < 72 h on vasopressor and < 24 h of AKI.
Aqueous lithium-ion batteries (ALIBs) are promising for large-scale energy storage systems because of the cost-effective, intrinsically safe, and environmentally friendly properties of aqueous electrolytes. Practical application is however impeded by interfacial side-reactions and the narrow electrochemical stability window (ESW) of aqueous electrolytes. Even though higher electrolyte salt concentrations (e.
View Article and Find Full Text PDFRechargeable magnesium batteries could provide future energy storage systems with high energy density. One remaining challenge is the development of electrolytes compatible with the negative Mg electrode, enabling uniform plating and stripping with high Coulombic efficiencies. Often improvements are hindered by a lack of fundamental understanding of processes occurring during cycling, as well as the existence and structure of a formed interphase layer at the electrode/electrolyte interface.
View Article and Find Full Text PDFPerioperative monitoring of cardiac function is beneficial for early detection of cardiovascular complications. The standard of care for cardiac monitoring performed by trained cardiologists and anesthesiologists involves a manual and qualitative evaluation of ultrasound imaging, which is a time-demanding and resource-intensive process with intraobserver- and interobserver variability. In practice, such measures can only be performed a limited number of times during the intervention.
View Article and Find Full Text PDFBackground: Mechanical wave velocity (MWV) measurement is a promising method for evaluating myocardial stiffness, because these velocities are higher in patients with myocardial disease.
Objectives: Using high frame rate echocardiography and a novel method for detection of myocardial mechanical waves, this study aimed to estimate the MWVs for different left ventricular walls and events in healthy subjects and patients with aortic stenosis (AS). Feasibility and reproducibility were evaluated.
IEEE Trans Ultrason Ferroelectr Freq Control
October 2023
Ultrasound image quality is of utmost importance for a clinician to reach a correct diagnosis. Conventionally, image quality is evaluated using metrics to determine the contrast and resolution. These metrics require localization of specific regions and targets in the image such as a region of interest (ROI), a background region, and/or a point scatterer.
View Article and Find Full Text PDFBackground: An aberration correction algorithm has been implemented and demonstrated in an echocardiographic clinical trial using two-dimensional (2D) imaging. The method estimates and compensates arrival time errors between different sub-aperture processor (SAP) signals in a matrix array probe.
Methods: Five standard views of channel data cineloops were recorded from 22 patients (11 male and 11 female) resulting in a total of 116 cineloops.
Transition metal (TM) dissolution is a direct consequence of cathode-electrolyte interaction, having implications not only for the loss of redox-active material from the cathode but also for the alteration of solid electrolyte interphase (SEI) composition and stability at the counter electrode. It has widely been reported that the limited anodic stability of typical carbonate-based electrolytes, specifically ethylene carbonate (EC)-based electrolytes, makes high-voltage cathode performance problematic. Hence, the more anodically stable tetramethylene sulfone (SL) has herein been utilized as a co-solvent and a substitute for EC in combination with diethyl carbonate (DEC) to investigate the TM dissolution behavior of LiNCAl (NCA) and LiMnO (LMO).
View Article and Find Full Text PDFIn this bibliometric study, we analyze two of the six battery research subfields identified in the BATTERY 2030+ roadmap: Materials Acceleration Platform and Smart functionalities: Sensing. In addition, we analyze the entire research field related to BATTERY 2030+ as a whole. We (a) evaluate the European standing in the two subfields/the BATTERY 2030+ field in comparison to the rest of the world, and (b) identify strongholds of the two subfields/the BATTERY 2030+ field across Europe.
View Article and Find Full Text PDFThe water-in-salt electrolytes have promoted aqueous Li-ion batteries to become one of the most promising candidates to overcome safety concerns/issues of traditional Li-ion batteries. A simple increase of Li-salt concentration in electrolytes can successfully expand the electrochemical stability window of aqueous electrolytes beyond 2 V. However, necessary stability improvements require an increase in complexity of the ternary electrolytes.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
December 2022
Accurate quantification of cardiac valve regurgitation jets is fundamental for guiding treatment. Cardiac ultrasound is the preferred diagnostic tool, but current methods for measuring the regurgitant volume (RVol) are limited by low accuracy and high interobserver variability. Following recent research, quantitative estimators of orifice size and RVol based on high frame rate 3-D ultrasound have been proposed, but measurement accuracy is limited by the wide point spread function (PSF) relative to the orifice size.
View Article and Find Full Text PDFObjective: To compare school grades of adolescents in Norway born with isolated cleft with those of their unaffected peers.
Design: Population-based cohort study.
Setting: Norway.
LiCoO (LCO) is one of the most-widely used cathode active materials for Li-ion batteries. Even though the material undergoes an electronic two-phase transition upon Li-ion cell charging, LCO exhibits competitive performance in terms of rate capability. Herein the insulator-metal transition of LCO is investigated by Raman spectroscopy complemented with DFT calculations and a developed sampling volume model.
View Article and Find Full Text PDF