This study assessed the impact of pre-enlarging the root canal using a size 25 K-file on the fracture incidence of three reciprocating instruments after multiple uses. After a glide path performed with a size 15 K-file, the instruments (Reciproc R25, Reciproc Blue R25, and WaveOne Gold Primary) were initially used in 936 root canals. Then, for the second and third uses (933 and 927, respectively), a pre-enlargement using a size 25 K-file at the working length was done.
View Article and Find Full Text PDFIntroduction: Leukemia and lymphoma mimicking periapical conditions can lead to significant diagnostic pitfalls. Guidance for endodontists in managing such cases is barely explored. This systematic review aimed to summarize the clinicopathologic, imaging, and management aspects of leukemia/lymphoma that mimicked periapical conditions and resulted in endodontic treatment.
View Article and Find Full Text PDF: To assess the cytocompatibility, antibacterial and anti-biofilm efficacy of grape seed extract (GSE) and quercetin hydrogels versus calcium hydroxide (CH) as intracanal medications (ICMs) against an endodontic ex vivo biofilm model. : Single-rooted teeth ( = 50) were prepared and sterilized before being infected with to develop a mature biofilm. They were divided into five equal groups according to the ICM used: G1: medicated with CH paste, G2: medicated with GSE hydrogel, G3: medicated with quercetin hydrogel, G4: positive control group that was infected and not medicated, and G5: negative control group that was neither infected nor medicated.
View Article and Find Full Text PDFIntroduction: To compare the stress produced on the walls of simulated canals by rotary instruments with varied tip and taper sizes.
Methods: Ninety isotropic transparent blocks, each containing a 60-degree curved canal, were distributed into 18 groups (n = 5) based on the instrument tip (sizes 10, 15, 20, 25, 30, and 35) and taper (sizes 0.02, 0.
Purpose: Individuals with isolated GH deficiency (IGHD) due to a mutation in the GHRH receptor gene have a normal life expectancy and above 50 years of age, similar total cognitive performance, with better attention and executive function than controls. Our objectives were to evaluate their brain morphometry and brain aging using MRI.
Methods: Thirteen IGHD and 14 controls matched by age, sex, and education, were enrolled.
This study evaluated the impact of long-term storage conditions (medium and time) on the development of experimental dentinal microcracks through micro-computed tomography. Sixty freshly extracted premolars were stored in formalin, water, or dry conditions (n = 20) and scanned after 72 h, 30 days, 6 months and 3 years of extraction. The effect of the storage medium and time on the occurrence of dentinal defects was statistically evaluated.
View Article and Find Full Text PDFIntroduction: This study aimed to assess the canal transportation with 6 preparation systems.
Methods: Sixty curved mesial roots of mandibular molars were scanned, and their root canals (n = 20 per group) were prepared with XP-endo Shaper, BioRace, ProTaper Next, Twisted File Adaptive, Reciproc, or Reciproc Blue systems. After preparation, a new scan was conducted, and transportation was determined by comparing the geometric center of the canal in 13,542 cross-sectional slices.
Aim: The aim of this study is to compare the stress produced on the internal walls of simulated canals by nine rotary and four reciprocating systems.
Methodology: Sixty-five isotropic transparent blocks containing a 60° curved and tapered simulated canal were selected and distributed into 13 groups (n = 5) according to the preparation system: BioRace, HyFlex EDM, iRaCe, Mtwo, One RECI, ProTaper Next, RaCe EVO, Reciproc, Reciproc Blue, R-Motion, VDW.ROTATE, XP-Endo Rise Shaper, and XP-Endo Shaper.
Introduction: This study aimed to compare the in vivo accuracy and precision of 3 electronic apex locators (EALs) in determining the position of the major foramen using micro-computed tomographic (micro-CT) technology.
Methods: After access preparation of 23 necrotic or vital teeth from 5 patients, canals were negotiated, and hand files were used to determine the position of the foramen with 3 EALs: Propex Pixi (Dentsply Maillefer, Ballaigues, Switzerland), Woodpex III (Woodpecker Medical Instrument Co, Guilin, China), and Root ZX II (J Morita, Tokyo, Japan). After fixing the silicon stop to the file, teeth were extracted and scanned in a micro-CT device with and without the instrument inserted into the canal.
Introduction: This study aimed to evaluate the effects of root canal enlargement on the danger zone (DZ) of mandibular molars.
Methods: Thirty mesial roots of mandibular first molars were scanned in micro-computed tomography (S1). Canals were sequentially enlarged with rotary instruments up to sizes 30/0.
Introduction: This study aimed to compare the in vivo accuracy of Wirele-X and RootZX II electronic apex locators (EALs) in determining the position of the major foramen using micro-computed tomography (micro-CT) as the analytical tool.
Methods: Eleven vital teeth planned for extraction from 5 patients were used. After conventional access cavity preparation, root canals were flared and negotiated up to the apical third with sizes 08 and 10 K-files followed by irrigation with 2.
Aim: To assess the interfacial adaptation (gap-containing areas) of two root canal sealers (EndoSequence BC Sealer and AH Plus) to a conventional gutta-percha (GP) cone (GP-sealer interface) in oval-shaped canals filled using the single cone technique.
Methodology: Sixteen teeth with oval-shaped canals were selected, scanned in a micro-computed tomographic device, and pair-matched according to the volume, aspect ratio and configuration of root canals. Root canals were then sequentially prepared with WaveOne Gold Primary and Large instruments, followed by filling with WaveOne Large GP points associated with either the premixed calcium-silicate EndoSequence BC Sealer or the epoxy resin-based AH Plus sealer (n = 8 per group) using the single cone technique.
Canal filling materials and techniques have been one of the most studied topics in Endodontics. A simple search using the mesh term "root canal filling" in PubMed revealed more than 11 000 articles, an impressive number that is much higher than "root canal disinfection" (5544 articles) or even the popular "root canal preparation" (8527 articles). The overriding importance attributed to root filling procedures is not merely intuitive.
View Article and Find Full Text PDFIn the last decades, the move of medicine towards minimally invasive treatments is notorious and scientifically grounded. As dentistry naturally follows in its footsteps, minimal access preparation have also becume a trend topic in the endodontic field. This procedure aims to maximize preservation of dentine tissue backed up by the idea that this is an effective way to reduce the incidence of post-treatment tooth fracture.
View Article and Find Full Text PDFThe purpose of this narrative review was to discuss the scientific milestones that led to the current understanding of the root dentinal microcrack phenomenon based on the interplay between the usage of micro-computed tomography (micro-CT) as an analytical tool alongside a close-to-mouth experimental model. In 2009, reports on the development of dentinal microcracks in extracted teeth after root canal preparation triggered an awareness of the potential for vertical root fractures (VRFs) of endodontically treated teeth could be developed from defects created by the mechanical stress of nickel-titanium preparation systems on dentine. This assumption was taken for granted, even though no cause-effect relationship had been scientifically demonstrated.
View Article and Find Full Text PDFAim: To describe the prevalence of periapical lesions, root canal treatments and coronal restorations on teeth adjacent to either implant- or natural tooth-supported crowns using cone-beam computed tomography (CBCT) assessment compared to nonadjacent teeth.
Methodology: A total of 1249 CBCT volumes were screened by five pre-calibrated observers in 11 health centres. A step-by-step screening protocol was implemented and reviewed every 3 months, and mandatory setting characteristics were established for all CBCT scans using dedicated visualization software.
Aim: To evaluate the influence of traditional and conservative access cavity preparations on the remaining dentine thickness in the coronal third of mesial canals of extracted mandibular molars prepared with reciprocating instruments using micro-computed tomography as the analytical tool.
Methodology: Seventy extracted mandibular molars were scanned at a pixel size of 19 μm. From this initial sample, 20 teeth were selected, pair-matched and distributed into two groups (n = 10) according to the access cavity preparation: traditional (TradAC) or conservative (ConsAC).
Objectives: This study evaluated the effect of repeated uses and autoclaving in the instrumented area, fracture resistance, and time of instrumentation of thermally treated nickel-titanium reciprocating systems.
Materials And Methods: Two hundred simulated canals were instrumented using Reciproc Blue and WaveOne Gold. Each file was used up to 10 times or until fracture.
Aim: To compare the bond strength of an epoxy resin-based sealer and two calcium silicate-based sealers (CSS) to gutta-percha discs using a new method.
Methodology: Round discs of gutta-percha (n = 60), measuring 10 mm in diameter and 2 mm in thickness, were placed on a glass plate and a drop of each sealer (AH Plus, EndoSequence BC Sealer and EndoSeal MTA) was placed on their surface. Another identical disc was placed onto the first one and a standardized weight (0.
Aim: To assess the impact of mechanical overinstrumentation of root canals in extracted teeth on the development of dentinal microcracks in the apical portion of the root by means of micro-computed tomographic (micro-CT) analysis. Root canal preparation short of the canal terminus and at the apical foramen (AF) were used as controls.
Methodology: Twenty 2-rooted maxillary premolars with two canals were selected, scanned in a micro-CT device and the root canals prepared sequentially using Reciproc M-Wire R25 instruments to working lengths: 1 mm short of the AF (AF - 1 mm), at the AF (AF), and overinstrumentation (AF + 1 mm).
Objectives: This study evaluated the danger zone (DZ) in mesial roots of mandibular molars and the correlation between anatomical references of the DZ and some anatomical landmarks including tooth/root length, depth of mesial and distal grooves, and inter-canal orifices distance.
Material And Methods: Twenty-eight mesial roots of mandibular molars with 2 independent canals were scanned and divided into 2 groups according to root length. The anatomical landmarks were correlated (Pearson or Spearman coefficients) with root level, thickness, and position of the DZ and also compared (independent samples t or Mann-Whitney tests) between the 2 groups at α = 5%.
Introduction: This study assessed the number of mesial and distal canals of mandibular molars in which the R-Pilot pathfinding reciprocating instrument reached the working length (WL) during macro glide path procedure. Fracture and deformation rates were also evaluated.
Methods: One hundred fifty-six root canals of 52 teeth were scouted to the length of the apical foramen.
Anatomical variation in wild canids is rarely described. Altered shapes, uni- or bilaterally situated, were observed in ventral laminae of C6 and/or in C7 vertebral body of two fox species: Lycalopex gymnocercus and Cerdocyon thous. The specimens were young adults, collected dead on highways in southern Brazil.
View Article and Find Full Text PDFAnat Histol Embryol
November 2020
Criollo horse breeding is an important economic activity in South America. Because of their athletic performance, these animals tend to show great incidence of musculoskeletal disorders, many of them diagnosed by means of perineural blocks. However, incorrect interpretation of these blocks may be due to anatomical differences in nerve distribution.
View Article and Find Full Text PDFIntroduction: The purpose of this study was to evaluate the ability of the XP-endo Shaper instrument (FKG Dentaire, La Chaux-de-Fonds, Switzerland) during the removal of root fillings from oval-shaped canals. M-Wire Reciproc and Reciproc Blue systems (VDW, Munich, Germany) were used as reference instruments for comparison, and micro-computed technology was used as an analytical tool.
Methods: Thirty mandibular incisors with oval-shaped canals were matched based on similar anatomic features of the canal (eg, volume, aspect ratio, and 3-dimensional configuration) after scanning procedures.