Publications by authors named "Eric R Bohm"

Background And Purpose:  National joint replacement registries were developed for prospective monitoring of outcomes and post-market surveillance of implants. Increasingly registry data informs practice. However, analysis of a registry can only be as good as the data it captures on the population of interest.

View Article and Find Full Text PDF

Background: Cementless total knee arthroplasty (TKA) is rising in popularity. The literature supporting its use over cemented TKA remains sparse. Using the Canadian Joint Replacement Registry (CJRR), we sought to investigate cementless versus cemented fixation in modern primary TKA and (1) determine whether there is an overall difference in revision by fixation, (2) perform a subanalysis of the most-commonly used cementless TKA brand in Canada, and (3) identify the reasons for revision.

View Article and Find Full Text PDF

Bacground: The use of cemented fixation is widely recommended in hip arthroplasty for hip fractures, although it is not used universally.

Methods: We describe the trends in cementing prevalence in hemiarthroplasty for hip fractures in Canada for patients ≥55 years old between April 2017 and March 2022.

Results: The national prevalence of cemented fixation increased from 43% in 2017/18 to 58% in 2021/22, but there was a large variety of both the baseline prevalence and the trends across the country and between individual hospitals.

View Article and Find Full Text PDF

Background: Body mass index (BMI) thresholds are used as eligibility criteria to reduce complication risk in total joint arthroplasty (TJA). This approach oversimplifies preoperative risk assessment and inadvertently restricts access to effective surgical treatment for osteoarthritis. A prior survey of orthopaedic surgeons in the United States identified complex underlying factors that influence BMI considerations.

View Article and Find Full Text PDF

Aims: The primary aim of this trial was to compare the subsidence of two similar hydroxyapatite-coated titanium femoral components from different manufacturers. Secondary aims were to compare rotational migration (anteversion/retroversion and varus/valgus tilt) and patient-reported outcome measures between both femoral components.

Methods: Patients were randomized to receive one of the two femoral components (Avenir or Corail) during their primary total hip arthroplasty between August 2018 and September 2020.

View Article and Find Full Text PDF

Aims: Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design.

View Article and Find Full Text PDF

Background: Hemiarthroplasty is a common treatment for displaced femoral neck fractures, but limited Canadian data are available about hemiarthroplasty failure. We evaluated the frequency and predictors of hemiarthroplasty failure in Manitoba.

Methods: In this retrospective multicentre province-wide study, billing and joint registry databases showed 4693 patients who had hemiarthroplasty for treatment of femoral neck fracture in Manitoba over an 11-year period (2005-2015), including 155 hips with subsequent reoperations (open or closed) for treatment of hemiarthroplasty failure.

View Article and Find Full Text PDF

Background: Patient-reported outcome measures (PROMs) are validated questionnaires that are completed by patients. Arthroplasty registries vary in PROM collection and use. Current information about registry collection and use of PROMs is important to help improve methods of PROM data analysis, reporting, comparison, and use toward improving clinical practice.

View Article and Find Full Text PDF
Article Synopsis
  • * Conducted as a double-blinded randomized controlled trial, it included 54 patients, revealing no significant difference in overall coronal alignment between the two methods, while PSI did show better accuracy for tibial slope.
  • * The researchers concluded that despite slightly better results with PSI, the added costs do not warrant its use, given the negligible improvements observed in other areas like patient outcomes and surgical efficiency.
View Article and Find Full Text PDF

Background: A novel symmetric posterior condylar design and option of a femoral component with an outer zirconium oxide layer were introduced to a successful asymmetric condylar total knee arthroplasty system in 2005. Given the paucity of information on this modified design, we performed a study to determine its early to midterm survivorship and performance.

Methods: Patients who received the Genesis II Symmetric Posterior Condyle or Legion Primary total knee (cobalt–chromium [CoCr] or oxidized zirconium–niobium [OxZr]) (Smith & Nephew) implanted at the study centre between March 2007 and December 2013 were enrolled into a prospective database.

View Article and Find Full Text PDF

Background: This study aimed to assess differences in the fixation and functional outcomes between pegged and keeled all-polyethylene glenoid components for standard total shoulder arthroplasty.

Methods: Patients were randomized to receive a keeled or pegged all-polyethylene glenoid component. We used model-based radiostereometric analysis (RSA) to assess glenoid fixation and subjective outcome measures to assess patient function.

View Article and Find Full Text PDF

Multicentre studies are rare in three dimensional motion analyses due to challenges associated with combining waveform data from different centres. Principal component analysis (PCA) is a statistical technique that can be used to quantify variability in waveform data and identify group differences. A correction technique based on PCA is proposed that can be used in post processing to remove nuisance variation introduced by the differences between centres.

View Article and Find Full Text PDF

Background: National joint replacement registries outside North America have been effective in reducing revision risk. However, there is little information on the role of smaller regional registries similar to those found in Canada or the United States. We sought to understand trends in total hip (THA) and knee (TKA) arthroplasty revision patterns after implementation of a regional registry.

View Article and Find Full Text PDF

Background and purpose - There is no consensus about the outcome of simultaneous vs. staged bilateral total knee arthroplasty (TKA). We examined this issue by analyzing 238,373 patients.

View Article and Find Full Text PDF

The purpose of this research was to determine the failure mechanisms and damage features of a TriboFit acetabular buffer implanted directly against a native, prepared acetabulum which was revised after 11months. Retrieval analyses were carried out via light microscopy, gravimetric wear assessment, and observer scoring of visible damage features on the buffer. The volume of material abraded from the backside of the buffer was estimated via three-dimensional reconstruction using a laser scanner.

View Article and Find Full Text PDF

This study examines the damage and wear on the polyethylene (PE) inserts from 52 retrieved Genesis II total knee replacements to identify differences in tribological performance between matched pairs of cobalt-chromium (CoCr) and oxidized zirconium (OxZr) femoral components. Observer damage scoring and microcomputed tomography were used to quantify PE damage and wear, respectively. No significant differences were found between CoCr and OxZr groups in terms of PE insert damage, surface penetration, or wear.

View Article and Find Full Text PDF

Objective: As rates of total joint arthroplasty (TJA) for osteoarthritis (OA) rise, there is a need to ensure appropriate use. We undertook this study to develop criteria for appropriate use of TJA.

Methods: In prior work, we used qualitative methods to separately assess OA patients' and arthroplasty surgeons' perceptions regarding appropriateness of patient candidates for TJA.

View Article and Find Full Text PDF

Background: Primary total hip and primary total knee surgeries are commonly performed to improve patients' quality of life and functional status.

Aim: This longitudinal retrospective study (N = 851) examined self-reported quality of life and functional status over the preoperative and postoperative periods: 12 months prior to surgery, one month prior to surgery and 12 months following surgery.

Methods: A linear mixed effects model was used to analyze the changes in quality of life and functional status over the sampling period.

View Article and Find Full Text PDF

Lubricant protein concentration is known to affect crosslinked polyethylene wear in in vitro testing; however, the biochemical nature of these lubricants may also have a significant effect on wear and dictate its clinical relevance. A modified approach to pin-on-disc testing was implemented to explore the effect of four biochemically different lubricants on the wear of two types of crosslinked polyethylene materials (XLK™ and Marathon™; DePuy Synthes, Warsaw, IN, USA). XLK was associated with higher wear rates than Marathon.

View Article and Find Full Text PDF

Background And Purpose: We previously reported on a randomized controlled trial (RCT) that examined the effect of adding tobramycin to bone cement after femoral stem migration. The present study examined femoral head penetration into both conventional and highly crosslinked polyethylene acetabular liners in the same group of RCT patients, with a minimum of 5 years of postoperative follow-up.

Patients And Methods: Linear penetration of the femoral head into an X3 (Stryker) crosslinked polyethylene (XLPE) liner was measured in 18 patients (19 hips) using radiostereometric analysis (RSA).

View Article and Find Full Text PDF
Article Synopsis
  • - The study introduces a new energy dissipation wear model for polyethylene used in total knee replacements, which focuses on the material's molecular behavior over time and includes factors like tractive rolling and contact pressure.
  • - This model was tested against various wear simulation methods, including pin-on-disk tests and knee simulators, to evaluate its effectiveness.
  • - Results showed that the new model provides better predictive accuracy for wear outcomes compared to previously established wear models.
View Article and Find Full Text PDF

Biochemical analyses were performed on osteoarthritic and periprosthetic synovial fluid in order to propose changes to lubricant specifications currently outlined in orthopaedic wear testing standards. Osteoarthritic and periprosthetic synovial fluid samples were obtained from the hip and knee joints of 40 patients. The samples in each group were analysed and compared in order to identify differences between the protein concentration, constituent fractions, osmolality, thermal stability and the hyaluronic acid concentration and molecular weight distribution of osteoarthritic and periprosthetic synovial fluid.

View Article and Find Full Text PDF

The present study investigates the performance of ceramic-on-ceramic total hip replacements by combining a retrieval analysis with a survivorship analysis to elucidate mechanisms that led to clinical failure. Semiquantitative surface damage assessment, contact profilometry, contour measurements, and scanning electron microscopy were performed to characterize the types and quantify the extent of surface damage on the retrieved ceramic components. The implantation period was positively correlated with both damage scores of the femoral heads (R = 0.

View Article and Find Full Text PDF

Background: The role of aspirin in thromboprophylaxis after total hip arthroplasty (THA) is controversial.

Objective: To compare extended prophylaxis with aspirin and dalteparin for prevention of symptomatic venous thromboembolism (VTE) after THA.

Design: Multicenter randomized, controlled trial with a noninferiority design based on a minimal clinically important difference of 2.