Purpose: To investigate the repeatability of the Developmental Eye Movement (DEM) Test in a group of third grade elementary school students.
Methods: Thirty, third grade children who passed a modified clinical technique vision screening were given the DEM and then retested 2 weeks later.
Results: A clinically and statistically significant improvement in mean scores from test to retest was found on the vertical time, horizontal time, and ratio score.