Publications by authors named "Eric L Kilpatrick"

Presented here is the National Institute of Standards and Technology (NIST) Mass Calculator, a software tool that provides both a relative molecular mass () value and an associated uncertainty value for a given protein sequence. The calculation of a protein based on its amino acid residue sequence is performed by many software applications. Unfortunately, many of the results do not agree with each other.

View Article and Find Full Text PDF

Intact protein analysis by liquid chromatography-mass spectrometry (LC-MS) is now possible due to the improved capabilities of mass spectrometers yielding greater resolution, mass accuracy, and extended mass ranges. Concurrent measurement of post-translational modifications (PTMs) during LC-MS of intact proteins is advantageous while monitoring critical proteoform status, such as for clinical samples or during production of reference materials. However, difficulties exist for PTM identification when the protein is large or contains multiple modification sites.

View Article and Find Full Text PDF

Use of labeled (15)N proteins and peptides as internal standards in isotope-dilution mass spectrometry for the quantification of proteins has been increasing and is now accepted as a gold standard for this analysis. As a necessary reagent in this process, stable heavy isotope-labeled internal standards must be rigorously characterized in a number of ways including identity, concentration, purity, and structure. Additionally, the degree of the incorporation of the heavy isotope is a critical feature to consider.

View Article and Find Full Text PDF

Chromatographic separation of monosaccharides hydrolyzed from glycoconjugates or complex, aggregate biomaterials, can be achieved by classic analytical methods without a need for derivatizing the monosaccharide subunits. A simple and sensitive method is presented for characterizing underivatized monosaccharides following hydrolysis from N- and O-linked glycoproteins using high-performance liquid chromatography separation with mass spectrometry detection (LC-MS). This method is adaptable for characterizing anything from purified glycoproteins to mixtures of glycoforms, for relative or absolute quantification applications, and even for the analysis of complex biomaterials.

View Article and Find Full Text PDF

Perchlorate, an inorganic anion, has recently been recognized as an environmental contaminant by the US Environmental Protection Agency. Urine is the preferred matrix for assessment of human exposure to perchlorate. Although the measurement technique for perchlorate in urine was developed in 2005, the calibration and quality assurance aspects of the metrology infrastructure for perchlorate are still lacking in that there is no certified reference material (CRM) traceable to the International System of Units.

View Article and Find Full Text PDF

Levels of C-reactive protein (CRP) in serum are correlated with inflammation and disease in humans. A higher level quantitative method, such as isotope-dilution mass spectrometry (ID-MS) is needed to compare and standardize the many commercial CRP assays. We compare the expression and purification of (15)N-CRP from Escherichia coli and Pichia pastoris and show that the protein isolated from P.

View Article and Find Full Text PDF

Selenoprotein P (SePP) is a unique selenium-containing protein responsible for the transport and distribution of the essential trace element selenium (Se) through the human body with the concentration of SePP in human blood representing the most useful marker of Se nutritional status. Although SePP has been extensively studied, the structure of SePP in human plasma remains unresolved. Two potential isoforms of SePP have been identified by Western blot analyses distinguished principally by differences in migration (51 kDa and 61 kDa).

View Article and Find Full Text PDF

NIST has performed preliminary research on applying a calibration methodology based on the method of standard additions to the quantification of peptides via reverse-phase liquid chromatography coupled to inductively coupled plasma mass spectrometry (RPLC-ICP-MS). A microwave-assisted lanthanide labeling procedure was developed and applied to derivatize peptides using the macrocyclic bifunctional chemical chelator DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid), which significantly improved the lanthanide labeling yield and reduced reaction times compared to benchtop labeling procedures. Biomolecular MS technologies of matrix-assisted laser desorption ionization (MALDI)-MS and electrospray ionization (ESI)-MS/MS were used in concert with ICP-MS to confirm the results of microwave labeling, sample cleanup and standard additions experiments for several test peptides.

View Article and Find Full Text PDF

This paper describes the development of a reference measurement procedure to quantify human C-reactive protein (CRP) in serum using affinity techniques prior to tryptic digestion and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the certification of reference materials in clinically relevant ranges. The absence of a suitable internal standard for the CRP measurement, necessary to eliminate potential measurement bias in both the affinity purification and trypsin digestion steps, was addressed using the method of standard addition. The standard addition quantification approach was combined with affinity purification, using an anti-CRP monoclonal antibody conjugated to polystyrene beads, trypsin digestion of the purified protein, and LC-MS/MS analysis of CRP tryptic peptides.

View Article and Find Full Text PDF

Between 1 and 2% of proteins coded for in the human genome, including all G protein gamma subunits, are predicted to be prenylated. Subsequently, prenylated proteins are proteolytically cleaved at the C terminus and carboxymethylated. These reactions are generally obligatory events required for functional expression of prenylated proteins.

View Article and Find Full Text PDF

Adenosine A2a receptors are found in coronary vascular tissue although, their presence in myocardium is subject to investigation. Although there have been numerous studies on adenosine A2a receptor agonist effects on contractility and cAMP levels in ventricular myocytes, these have yielded conflicting results. Negative pharmacological studies have even led to the conclusion that A2a receptors are not present in cardiac myocytes.

View Article and Find Full Text PDF