Introduction: The aim of this study was to assess variation in prostate contouring 12 months following a structured interactive educational intervention (EI) and to test the hypothesis that EIs positively impact on prostate contouring accuracy and consistency long term.
Methods: A common set of computed tomography (CT) and magnetic resonance imaging (MRI) data sets were used to assess prostate contouring consistency before, immediately after and 12 months following an EI. No further EIs were provided after the initial EI.
Purpose: To assess whether an education program on CT and MRI prostate anatomy would reduce inter- and intraobserver prostate contouring variation among experienced radiation oncologists.
Methods And Materials: Three patient CT and MRI datasets were selected. Five radiation oncologists contoured the prostate for each patient on CT first, then MRI, and again between 2 and 4 weeks later.