Background: Mortality and intraventricular hemorrhage (IVH) are common adverse outcomes in preterm infants and are challenging to predict clinically. Sample entropy (SE), a measure of heart rate variability (HRV), has shown predictive power for sepsis and other morbidities in neonates. We evaluated associations between SE and mortality and IVH in the first week of life.
View Article and Find Full Text PDFThe continuous monitoring of arterial blood pressure (BP) is vital for assessing and treating cardiovascular instability in a sick infant. Currently, invasive catheters are inserted into an artery to monitor critically-ill infants. Catheterization requires skill, is time consuming, prone to complications, and often painful.
View Article and Find Full Text PDFBackground: Automated measurements of electrocardiographic (ECG) intervals by current-generation digital electrocardiographs are critical to computer-based ECG diagnostic statements, to serial comparison of ECGs, and to epidemiological studies of ECG findings in populations. A previous study demonstrated generally small but often significant systematic differences among 4 algorithms widely used for automated ECG in the United States and that measurement differences could be related to the degree of abnormality of the underlying tracing. Since that publication, some algorithms have been adjusted, whereas other large manufacturers of automated ECGs have asked to participate in an extension of this comparison.
View Article and Find Full Text PDFBackground: The feasibility of using photoplethysmography (PPG) for estimating heart rate variability (HRV) has been the subject of many recent studies with contradicting results. Accurate measurement of cardiac cycles is more challenging in PPG than ECG due to its inherent characteristics.
Methods: We developed a PPG-only algorithm by computing a robust set of medians of the interbeat intervals between adjacent peaks, upslopes, and troughs.
Background: Respiration rate (RR) is a critical vital sign that can be monitored to detect acute changes in patient condition (e.g., apnea) and potentially provide an early warning of impending life-threatening deterioration.
View Article and Find Full Text PDFDefibrillation is often required to terminate a ventricular fibrillation or fast ventricular tachycardia rhythm and resume a perfusing rhythm in sudden cardiac arrest patients. Automated external defibrillators rely on automatic ECG analysis algorithms to detect the presence of shockable rhythms before advising the rescuer to deliver a shock. For a reliable rhythm analysis, chest compression must be interrupted to prevent corruption of the ECG waveform due to the artifact induced by the mechanical activity of compressions.
View Article and Find Full Text PDFBackground And Purpose: Automated measurements of electrocardiographic (ECG) intervals are widely used by clinicians for individual patient diagnosis and by investigators in population studies. We examined whether clinically significant systematic differences exist in ECG intervals measured by current generation digital electrocardiographs from different manufacturers and whether differences, if present, are dependent on the degree of abnormality of the selected ECGs.
Methods: Measurements of RR interval, PR interval, QRS duration, and QT interval were made blindly by 4 major manufacturers of digital electrocardiographs used in the United States from 600 XML files of ECG tracings stored in the US FDA ECG warehouse and released for the purpose of this study by the Cardiac Safety Research Consortium.
Background: ECG detection of ST-segment elevation myocardial infarction (STEMI) in the presence of left bundle-branch block (LBBB) is challenging due to ST deviation from the altered conduction. The purpose of this study was to introduce a new algorithm for STEMI detection in LBBB and compare the performance to three existing algorithms.
Methods: Source data of the study group (143 with acute MI and 239 controls) comes from multiple sources.
Although the importance of quality cardiopulmonary resuscitation (CPR) and its link to survival is still emphasized, there has been recent debate about the balance between CPR and defibrillation, particularly for long response times. Defibrillation shocks for ventricular fibrillation (VF) of recently perfused hearts have high success for the return of spontaneous circulation (ROSC), but hearts with depleted adenosine triphosphate (ATP) stores have low recovery rates. Since quality CPR has been shown to both slow the degradation process and restore cardiac viability, a measurement of patient condition to optimize the timing of defibrillation shocks may improve outcomes compared to time-based protocols.
View Article and Find Full Text PDFBackground: Interpretation of a patient's 12-lead ECG frequently involves comparison to a previously recorded ECG. Automated serial ECG comparison can be helpful not only to note significant ECG changes but also to improve the single-ECG interpretation. Corrections from the previous ECG are carried forward by the serial comparison algorithm when measurements do not change significantly.
View Article and Find Full Text PDFObjective: To test the potential value of more frequent QT interval measurement in hospitalized patients.
Design: We performed a prospective, observational study.
Setting: All adult intensive care unit and progressive care unit beds of a university medical center.
Unlabelled: Recent Scientific Statement from the American Heart Association (AHA) recommends that hospital patients should receive QT interval monitoring if certain conditions are present: QT-prolonging drug administration or admission for drug overdose, electrolyte disturbances (K, Mg), and bradycardia. No studies have quantified the proportion of critical care patients that meet the AHA's indications for QT interval monitoring. This is a prospective study of 1039 critical care patients to determine the proportion of patients that meet the AHA's indications for QT interval monitoring.
View Article and Find Full Text PDFElectrocardiographic (ECG) monitoring plays an important role in the management of patients with atrial fibrillation (AF). Automated real-time AF detection algorithm is an integral part of ECG monitoring during AF therapy. Before and after antiarrhythmic drug therapy and surgical procedures require ECG monitoring to ensure the success of AF therapy.
View Article and Find Full Text PDFAnn Noninvasive Electrocardiol
January 2009
Background: Commonly used techniques for QT measurement that identify T wave end using amplitude thresholds or the tangent method are sensitive to baseline drift and to variations of terminal T wave shape. Such QT measurement techniques commonly underestimate or overestimate the "true" QT interval.
Methods: To find the end of the T wave, the new Philips QT interval measurement algorithms use the distance from an ancillary line drawn from the peak of the T wave to a point beyond the expected inflection point at the end of the T wave.
Reduced-lead electrocardiographic systems are currently a widely accepted medical technology used in a number of applications. They provide increased patient comfort and superior performance in arrhythmia and ST monitoring. These systems have unique and compelling advantages over the traditional multichannel monitoring lead systems.
View Article and Find Full Text PDFA 12-lead electrocardiogram (ECG) reconstructed from a reduced subset of leads is desired in continued arrhythmia and ST monitoring for less tangled wires and increased patient comfort. However, the impact of reconstructed 12-lead lead ECG on clinical ECG diagnosis has not been studied thoroughly. This study compares the differences between recorded and reconstructed 12-lead diagnostic ECG interpretation with 2 commonly used configurations: reconstruct precordial leads V(2), V(3), V(5), and V(6) from V(1),V(4), or reconstruct V(1), V(3), V(4), and V(6) from V(2),V(5).
View Article and Find Full Text PDFThe details of digital recording and computer processing of a 12-lead electrocardiogram (ECG) remain a source of confusion for many health care professionals. A better understanding of the design and performance tradeoffs inherent in the electrocardiograph design might lead to better quality in ECG recording and better interpretation in ECG reading. This paper serves as a tutorial from an engineering point of view to those who are new to the field of ECG and to those clinicians who want to gain a better understanding of the engineering tradeoffs involved.
View Article and Find Full Text PDFQT surveillance of neonatal patients, and especially premature infants, may be important because of the potential for concomitant exposure to QT-prolonging medications and because of the possibility that they may have hereditary QT prolongation (long-QT syndrome), which is implicated in the pathogenesis of approximately 10% of sudden infant death syndrome. In-hospital automated continuous QT interval monitoring for neonatal and pediatric patients may be beneficial but is difficult because of high heart rates; inverted, biphasic, or low-amplitude T waves; noisy signal; and a limited number of electrocardiogram (ECG) leads available. Based on our previous work on an automated adult QT interval monitoring algorithm, we further enhanced and expanded the algorithm for application in the neonatal and pediatric patient population.
View Article and Find Full Text PDFQT interval measurement in the patient monitoring environment is receiving much interest because of the potential for proarrhythmic effects from both cardiac and noncardiac drugs. The American Heart Association and American Association of Critical Care Nurses practice standards for ECG monitoring in hospital settings now recommend frequent monitoring of QT interval when patients are started on a potentially proarrhythmic drug. We developed an algorithm to continuously measure QT interval in real-time in the patient monitoring setting.
View Article and Find Full Text PDFQT-interval measurements have clinical importance for the electrocardiographic recognition of congenital and acquired heart disease and as markers of arrhythmogenic risk during drug therapy, but software algorithms for the automated measurement of electrocardiographic durations differ among manufacturers and evolve within manufacturers. To compare automated QT-interval measurements, simultaneous paired electrocardiograms were obtained in 218 subjects using digital recorders from the 2 major manufacturers of electrocardiographs used in the United States and analyzed by 2 currently used versions of each manufacturer's software. The 4 automated QT and QTc durations were examined by repeated-measures analysis of variance with post hoc testing.
View Article and Find Full Text PDFA new pacemaker pulse detection and paced electrocardiogram (ECG) rhythm classification algorithm with high sensitivity and positive predictive value has been implemented as part of the Philips Medical Systems' (Andover, MA) ECG analysis program. The detection algorithm was developed on 1,108 paced ECGs with 16,029 individual pulse locations. It operates on 12-lead, 500 sample per second, 150 Hz low-pass filtered ECG signals.
View Article and Find Full Text PDF