Retained drain fragments, though rare, can lead to significant complications in orthopedic surgery(1). This case report presents a 57-year-old woman who developed gluteal tendinopathy and Trendelenburg gait two years after a total hip arthroplasty (THA) due to a retained drain fragment. A less experienced surgeon encountered resistance during drain removal on the first postoperative day and applied excessive force, unknowingly leaving a fragment inside.
View Article and Find Full Text PDFBackground: Subacromial pain syndrome (SPS) is the most common cause of shoulder pain. Therapeutic exercise is the first-line treatment for SPS; however, the ideal exercise type remains unclear. Here, we compared the effects of eccentric and concentric strengthening in patients with SPS.
View Article and Find Full Text PDFBackground: The measurement tool used for an accurate balance assessment should produce valid and reliable results in the population in which it is used.
Objectives: To examine whether two performance-based task tests are a reliable and valid measurement test to assess balance in patients with early and advanced knee osteoarthritis (KO).
Design: Reliability and concurrent validity research.
Background: This study aims to evaluate and compare stiffness and the load to failure values of our novel medial malleolus compression plate (MP) and 3,5mm 1/3 tubular plate (TP) in the treatment of vertical shear fractures of medial malleolar fractures.
Methods: Fourteen identical synthetic third generation composite polyurethane bone models of right distal tibia were randomly separated into two groups. Fracture models were created with a custom-made osteotomy guide to provide the same fracture characteristics in every sample (AO OTA type 44A2).
Appl Radiat Isot
September 2023
In this study, we investigated the impact of chemical etching on the light output and energy resolution of LYSO scintillators using simple, affordable laboratory equipment. We found that etching with phosphoric acid at temperatures between 180 °C and 190 °C improved the light output and energy resolution compared to mechanically polished crystals, even after minimal etching times. Our results show that with 7.
View Article and Find Full Text PDFBackground: In subacromial pain syndrome (SPS), it is unknown whether posterior shoulder stretching exercises (PSSE) with rapid eccentric contraction, a muscle energy technique, improve clinical and ultrasonographic outcomes more than no stretching or static PSSE.
Hypothesis: PSSE with rapid eccentric contraction is superior to no stretching and static PSSE in improving clinical and ultrasonographic outcomes in SPS.
Study Design: Randomized controlled trial.
Purpose: The aim of this study is to determine whether the 360° turn test is a reliable and valid evaluator that can be used to assess dynamic balance in patients with early (radiographic grades I and II) and advanced (radiographic grades III and IV) knee osteoarthritis.
Materials And Methods: This study is a methodological research. For the test time and step count of 360° turn test; test-retest reliability were determined by calculating the intraclass correlation coefficient and concurrent validity in patients with knee osteoarthritis was investigated by correlation with the timed up and go test time.
Anteroposterior (AP) lag screw, posteroanterior (PA) lag screw, or posterior buttress plate are usually performed for posterior malleolar fixation, but the biomechanically strongest technique is unclear. The aim of our study was to biomechanically compare 3 different fixation methods for posterior malleolar fractures; AP lag screw, PA lag screw, and closed-loop double endobutton. Fracture models were created using a thin blade power saw after drawing the fracture line.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
October 2021
Purpose: The aim was to compare active heel-slide exercise (AHSE) + standard physiotherapy (PT) to continuous passive motion (CPM) + standard PT during inpatient rehabilitation of total knee arthroplasty (TKA) patients in terms of postoperative outcomes.
Methods: Patients were randomly assigned into AHSE or CPM groups. Both groups received standard PT (range of motion and strengthening exercises, and ambulation) during hospital stay.
Objective The aim of this study was to investigate the effect of radial extracorporeal shock wave therapy (rESWT) on the treatment of trigger finger. Methods Eighteen patients, who were 2nd grade according to Quinnel classification and diagnosed with trigger finger, were included in this prospective cohort clinical study. The study consisted of only the experimental group and no control group.
View Article and Find Full Text PDFAccording to our knowledge, there is no prior article that reports functional results of medial collateral ligament (MCL) primary repair and insert change after MCL rupture and mobile-bearing dislocation as a late complication of unicompartmental knee replacement (UKR). Firstly, 63-year-old woman was treated with UKR due to anteromedial knee osteoarthritis of the right knee joint. 1 year after UKR surgery, she suffered from MCL rupture and mobile-bearing dislocation because of falls while getting on a public bus, and therefore, secondly, she was operated with MCL primary repair and mobile-bearing change and followed up for 2 years.
View Article and Find Full Text PDFPurpose: The aetiology of hallux valgus (HV) is multifactorial in nature. The first metatarsocuneiform joint obliquity is a well-known factor in the development of the deformity. The purpose of this study is to assess the correlation of different medial cuneiform radiological measures on the severity of HV.
View Article and Find Full Text PDFActa Orthop Traumatol Turc
October 2017
Objective: The aim of this study was to analyse the pattern of portal-tract healing, to compare the healing time of anteromedial and anterolateral portal tracts and to assess the impact of portal-tract delayed healing on the post-operative sub-acute and chronic anterior knee tenderness.
Methods: The study included 104 patients (68 males and 36 females; mean age: 49 ± 3.16 years (range; 17-66)) who have undergone knee arthroscopy.
Objective: The aim of this study was to assess the safety and stability of our novel anatomical patella plate and to compare its stability with tension band-wire technique.
Methods: A total of 12 cadaveric preserved knees (six right and six left patellae) with close patellar size were chosen to form two groups of six samples. Each group received either plate or tension band-wiring fixation for an experimentally created patella fracture.
Objectives: The aim of this study was to analyze the effect of tibial tunnel positioning in single bundle and double bundle ACL reconstructions on lateral meniscus anterior root.
Materials: Twelve single knee cadavers were used, 6 for a single bundle ACL reconstruction, which were reamed gradually starting from 8 mm, 9 mm and ended with a 10 mm reamers, while the other 6 were prepared for a double bundle ACL reconstruction in which 7 mm reamer for the AM tunnel and 6 mm reamer for the PL tunnel were used. After drilling, changes of lengths and thicknesses of anterior horns of the lateral menisci were recorded.
J Korean Neurosurg Soc
September 2016
Objective: Rod-screw fixation systems are widely used for spinal instrumentation. Although many biomechanical studies on rod-screw systems have been carried out, but the effects of rod contouring on the construct strength is still not very well defined in the literature. This work examines the mechanical impact of straight, 20° kyphotic, and 20° lordotic rod contouring on rod-screw fixation systems, by forming a corpectomy model.
View Article and Find Full Text PDFFor talar neck fractures, open reduction and internal fixation have been thought to facilitate revascularization and prevent osteonecrosis. Newer screw systems allow for placement of cannulated headless screws, which provide compression by virtue of a variable pitch thread. The present study compared the biomechanical fixation strength of cannulated headless variable-pitch screw fixation and locking plate fixation.
View Article and Find Full Text PDFUlus Travma Acil Cerrahi Derg
March 2015
Background: The aim of this study was to evaluate the biomechanical behavior of anterior inferior tibiofibularis ligament (AITFL) deficient human ankle under axial loading of ankle at stance phase of gait. In order to investigate the contribution of AITFL to ankle stability, an in vitro sequential experimental setup was simulated.
Methods: The measurement of posterior displacement of distal tibia and anterior displacement of the foot, in neutral position, secondary to axial compression, was performed by two non-contact video extensometers.
Background: Tennis elbow entails pain and tenderness over the lateral epicondyle. The exact cause of the condition is not fully understood. Type V collagen is a minor fibrillar collagen that intercalates with type I collagen and forms collagen fibrils.
View Article and Find Full Text PDFActa Orthop Traumatol Turc
October 2015
Lipoma arborescens is a rare intra-articular benign lesion. It is characterized by villous lipomatous proliferation of the synovial tissue and its etiology is not certain. Clinical presentation is usually long-standing, painless and slowly progressive swelling of the related joint.
View Article and Find Full Text PDFAim: Pseudomyogenic (epithelioid sarcoma-like) hemangioendothelioma is a rare local aggressive vascular tumor. Herein we present a 54-year-old male patient with a tumor on his index finger.
Case: The patient presented with a 1-year history of pain and swelling that progressively exacerbated.
The purpose of the present study was to evaluate the short-term results of metatarsal head resurfacing hemiarthroplasty in the treatment of advanced hallux rigidus. We reviewed 14 consecutive patients (5 males [35.71%], 9 females [64.
View Article and Find Full Text PDFEklem Hastalik Cerrahisi
February 2016
Objectives: This study aims to examine the motion and stability of the adjacent segment following rigid fixation of the lumbar spine.
Materials And Methods: The study included 17 fresh-frozen lamb lumbar spines (including the sacrum to T12). Biomechanical testing was performed using an axial compression testing machine.