Publications by authors named "Epari D"

: Locked plating for distal femur fractures is widely recommended and used. We systematically reviewed clinical studies assessing the benefits and harms of fracture fixation with locked plates in AO/OTA Type 32 and 33 femur fractures. : A comprehensive literature search of PubMed, Embase, Cinahl, Web of Science, and the Cochrane Database was performed.

View Article and Find Full Text PDF

Aim: Secondary bone healing requires an adequate level of mechanical stimulation expressed by the extent of interfragmentary motion in the fracture. However, there is no consensus about when the mechanical stimulation should be initiated to ensure a timely healing response. Therefore, this study aims to compare the effect of the immediate and delayed application of mechanical stimulation in a large animal model.

View Article and Find Full Text PDF

Large volume losses in weight bearing long bones are a major challenge in clinical practice. Despite multiple innovations over the last decades, significant limitations subsist in current clinical treatment options which is driving a strong clinical demand for clinically translatable treatment alternatives, including bone tissue engineering applications. Despite these shortcomings, preclinical large animal models of large volume segmental bone defects to investigate the regenerative capacity of bone tissue engineering strategies under clinically relevant conditions are rarely described in literature.

View Article and Find Full Text PDF

It is well known that mechanical stimulation promotes indirect fracture healing by triggering callus formation. We investigated the short-term response of healing tissue to mechanical stimulation to compare the changes in tissue stiffness during stimulation and resting phases in a preclinical case-series. Four sheep underwent a tibial osteotomy and were instrumented with a custom-made active fixator which applied a mechanical stimulation protocol of 1000 cycles/day, equally distributed over 12 h, followed by 12 h of rest.

View Article and Find Full Text PDF

The impact of the local mechanical environment in the fracture gap on the bone healing process has been extensively investigated. Whilst it is widely accepted that mechanical stimulation is integral to callus formation and secondary bone healing, treatment strategies that aim to harness that potential are rare. In fact, the current clinical practice with an initially partial or non-weight-bearing approach appears to contradict the findings from animal experiments that early mechanical stimulation is critical.

View Article and Find Full Text PDF

Internal fixation by plate osteosynthesis is the gold standard treatment for distal femur fractures. Despite improvements that preserve the biological conditions for bone healing, there are concerns standard locked plating constructs may be overly stiff. Biphasic plating is a novel concept designed to provide suitable fracture motion and increased implant strength to support early full weight-bearing.

View Article and Find Full Text PDF

This manuscript introduces a programable active bone fixator system that enables systematic investigation of bone healing processes in a sheep animal model. In contrast to previous systems, this solution combines the ability to precisely control the mechanical conditions acting within a fracture with continuous monitoring of the healing progression and autonomous operation of the system throughout the experiment. The active fixator system was implemented on a double osteotomy model that shields the experimental fracture from the influence of the animal's functional loading.

View Article and Find Full Text PDF

Long bone fractures typically heal via formation of an external callus, which helps stabilise the bone fragments. Callus composition and morphology influence the mechanical environment, which in turn regulates the progression of healing. Therefore characterising callus development over time is crucial in understanding this mechanobiological regulation.

View Article and Find Full Text PDF

Background: Fracture fixation has advanced significantly with the introduction of locked plating and minimally invasive surgical techniques. However, healing complications occur in up to 10% of cases, of which a significant portion may be attributed to unfavorable mechanical conditions at the fracture. Moreover, state-of-the-art plates are prone to failure from excessive loading or fatigue.

View Article and Find Full Text PDF
Article Synopsis
  • Bone fracture healing is influenced by the stability of fixation, and this study aimed to determine if mechanical stimulation is necessary throughout the healing process or just in the early phases.
  • A new bone defect model was tested on sheep, isolating fractures from functional loading, with groups receiving different levels of axial compression.
  • Results showed that fractures receiving early mechanical stimulation had significantly better healing outcomes compared to the control group, indicating that early stimulation alone is sufficient for effective bone repair.
View Article and Find Full Text PDF

Background: Golf is commonly considered a low-impact sport that carries little risk of injury to the knee and is generally allowed following total knee arthroplasty (TKA). Kinematic and kinetic studies of the golf swing have reported results relevant to the knee, but consensus as to the loads experienced during a swing and how the biomechanics of an individual's technique may expose the knee to risk of injury is lacking.

Objectives: Our objective was to establish (1) the prevalence of knee injury resulting from participation in golf and (2) the risk factors for knee injury from a biomechanical perspective, based on an improved understanding of the internal loading conditions and kinematics that occur in the knee from the time of addressing the ball to the end of the follow-through.

View Article and Find Full Text PDF

Introduction: Anatomic fit of intramedullary nails was suggested by previous studies to improve significantly when the nail radius of curvature (ROC) is closer to the average femoral anatomy. However, no attempt has been made to investigate the impact of different ROC designs on the nail insertion process. Therefore, this biomechanical study quantitatively compared the ease of insertion between femoral intramedullary nails with a 1.

View Article and Find Full Text PDF

Background and purpose - Constant fixator stiffness for the duration of healing may not provide suitable mechanical conditions for all stages of bone repair. We therefore investigated the influence of stiffening fixation on callus stiffness and morphology in a rat diaphyseal osteotomy model to determine whether healing time was shortened and callus stiffness increased through modulation of fixation from flexible to stiff. Material and methods - An external unilateral fixator was applied to the osteotomized femur and stiffened by decreasing the offset of the inner fixator bar at 3, 7, 14, and 21 days after operation.

View Article and Find Full Text PDF

Adaptive finite element models have allowed researchers to test hypothetical relationships between the local mechanical environment and the healing of bone fractures. However, their predictive power has not yet been demonstrated by testing hypotheses ahead of experimental testing. In this study, an established mechano-biological scheme was used in an iterative finite element simulation of sheep tibial osteotomy healing under a hypothetical fixation regime, "inverse dynamisation".

View Article and Find Full Text PDF

The treatment of large segmental bone defects remains a significant clinical challenge. Due to limitations surrounding the use of bone grafts, tissue-engineered constructs for the repair of large bone defects could offer an alternative. Before translation of any newly developed tissue engineering (TE) approach to the clinic, efficacy of the treatment must be shown in a validated preclinical large animal model.

View Article and Find Full Text PDF

Successful healing of long bone fractures is dependent on the mechanical environment created within the fracture, which in turn is dependent on the fixation strategy. Recent literature reports have suggested that locked plating devices are too stiff to reliably promote healing. However, in vitro testing of these devices has been inconsistent in both method of constraint and reported outcomes, making comparisons between studies and the assessment of construct stiffness problematic.

View Article and Find Full Text PDF

Iterative computational models have been used to investigate the regulation of bone fracture healing by local mechanical conditions. Although their predictions replicate some mechanical responses and histological features, they do not typically reproduce the predominantly radial hard callus growth pattern observed in larger mammals. We hypothesised that this discrepancy results from an artefact of the models' initial geometry.

View Article and Find Full Text PDF

Finite element models of bones can be created by deriving geometry from an X-ray CT scan. Material properties such as the elastic modulus can then be applied using either a single or set of homogeneous values, or individual elements can have local values mapped onto them. Values for the elastic modulus can be derived from the CT density values using an elasticity versus density relationship.

View Article and Find Full Text PDF

We propose the progressive mechanical expansion of cell-derived tissue analogues as a novel, growth-based approach to in vitro tissue engineering. The prevailing approach to producing tissue in vitro is to culture cells in an exogenous "scaffold" that provides a basic structure and mechanical support. This necessarily pre-defines the final size of the implantable material, and specific signals must be provided to stimulate appropriate cell growth, differentiation and matrix formation.

View Article and Find Full Text PDF

The transplantation of autologous bone graft as a treatment for large bone defects has the limitation of harvesting co-morbidity and limited availability. This drives the orthopaedic research community to develop bone graft substitutes. Routinely, supra-physiological doses of bone morphogenetic proteins (BMPs) are applied perpetuating concerns over undesired side effects and cost of BMPs.

View Article and Find Full Text PDF

The role of Bone Tissue Engineering in the field of Regenerative Medicine has been the topic of substantial research over the past two decades. Technological advances have improved orthopaedic implants and surgical techniques for bone reconstruction. However, improvements in surgical techniques to reconstruct bone have been limited by the paucity of autologous materials available and donor site morbidity.

View Article and Find Full Text PDF

The mechanical conditions in the repair tissues are known to influence the outcome of fracture healing. These mechanical conditions are determined by the stiffness of fixation and limb loading. Experimental studies have shown that there is a range of beneficial fixation stiffness for timely healing and that fixation stiffness that is either too flexible or too stiff impairs callus healing.

View Article and Find Full Text PDF

Mesenchymal progenitor cells (MPCs) represent an attractive cell population for bone tissue engineering. Their special immunological characteristics suggest that MPCs may be used in allogenic applications. The objective of this study was to compare the regenerative potential of autologous vs.

View Article and Find Full Text PDF

The reconstruction of large defects (>10 mm) in humans usually relies on bone graft transplantation. Limiting factors include availability of graft material, comorbidity, and insufficient integration into the damaged bone. We compare the gold standard autograft with biodegradable composite scaffolds consisting of medical-grade polycaprolactone and tricalcium phosphate combined with autologous bone marrow-derived mesenchymal stem cells (MSCs) or recombinant human bone morphogenetic protein 7 (rhBMP-7).

View Article and Find Full Text PDF

Well-established therapies for bone defects are restricted to bone grafts which face significant disadvantages (limited availability, donor site morbidity, insufficient integration). Therefore, the objective was to develop an alternative approach investigating the regenerative potential of medical grade polycaprolactone-tricalcium phosphate (mPCL-TCP) and silk-hydroxyapatite (silk-HA) scaffolds.Critical sized ovine tibial defects were created and stabilized.

View Article and Find Full Text PDF