Purpose: Endovascular aortic repair (EVAR) is currently expanding its feasibility thanks to design innovations, but hostile proximal necks and narrow iliac arteries are still a constraint, as expressed by the Instructions for Use (IFU) of most devices. Our aim is to report the preliminary results of the E-Tegra endograft in infrarenal abdominal aortic aneurysms (AAAs) performed in 15 high-volume centers.

Materials And Methods: The e-Tegra Italian endoGraft REgistry (TIGRE) is a prospectively maintained database of consecutive EVAR with the E-Tegra stent-graft across 15 participating centers between March 2021 and March 2023.

View Article and Find Full Text PDF

Background: Narrow and tortuous iliac axes are the second most common reason the feasibility of endovascular aortic repair (EVAR), and low-profile endografts were conceived to overcome the limitation of narrow and tortuous iliac axes. This study aims to report the initial results of EVAR performed with the ultra-low-profile Minos® abdominal endograft through a retrospective study conducted across 3 high-volume centers.

Methods: We retrospectively reviewed a prospectively maintained database collecting all consecutive EVAR performed with the Minos endograft across 3 Centers of Vascular Surgery between 2020 and 2023.

View Article and Find Full Text PDF

The treatment choice of visceral artery aneurysms in an elective setting is debated. The durability and the risk of reintervention with endovascular treatment are still reasons for concern, whereas open surgery is invasive and burdened by major complications. In anecdotal reports and isolated studies, robotic-assisted surgery seems to provide the possibility of a minimally invasive treatment and the durability of traditional open surgery, but the literature supporting this view is scarce.

View Article and Find Full Text PDF

Purpose: To describe our clinical experience of endovascular exclusion of popliteal artery aneurysms using the new self-expandable covered stent SOLARIS® (Scitech Medical, Brazil), and to report its results in the context of surgical and endovascular treatment of popliteal artery aneurysms.

Case Report: Among 20 popliteal artery aneurysms undergoing open or endovascular repair in 2022 and 2023, two patients were successfully treated with the Solaris stentgraft. Both patients had a patent popliteal artery and three run-off vessels.

View Article and Find Full Text PDF

Background: Ruptured splenic artery aneurysms (r-SAA), although rare, are burdened by high morbidity and mortality, even despite emergent surgical repair. It is suggested that endovascular treatment can achieve reduction in peri-operative death and complication rates, as in other vascular diseases, but evidence of such benefits is still lacking in this particular setting. We report a case of an r-SAA treated by trans-arterial embolization and then converted to open surgery for persistent bleeding, and we provide a systematic review of current results of open and endovascular repair of r-SAAs.

View Article and Find Full Text PDF
Article Synopsis
  • The review focused on gathering the latest information about anesthesia and other medical practices for a surgery called carotid endarterectomy.
  • They examined many studies from specific medical databases to find the best practices and results.
  • The findings suggested that using any anesthesia and checking brain function during surgery can help patients do better, but there wasn't enough proof on whether to reverse a medicine called heparin after surgery. They also mentioned keeping an eye on blood pressure after surgery, even though the evidence was weak.
View Article and Find Full Text PDF

On one hand, the main difficulties in establishing a wide, evidence-based consensus about the best approach to visceral artery aneurysms (VAAs) and pseudoaneurysms (VAPAs) are the paucity of data, due to their rarity in the general population, and the extreme heterogeneity of this group of diseases, which encompasses different aneurysm types, with different degrees of rupture risks according to their anatomical locations [...

View Article and Find Full Text PDF

Purpose: Newer generation abdominal endografts, including Treo (Terumo Aortic, Sunrise, Florida), have shown optimal safety and effectiveness in treating abdominal aortic aneurysms (AAAs), even with hostile anatomy over the short- and mid-term. The durability of such results, however, is still a controversial issue, due to the paucity of long-term data. Our aim is to show the long-term outcomes of endovascular aortic repair of both standard and hostile AAAs with the Treo endograft on a cohort of patients treated between 2016 and 2017.

View Article and Find Full Text PDF

Purpose: The commitment of multidisciplinary teams in antimicrobial stewardship programs (ASPs) is often inadequately considered, especially in surgical wards. We wanted to evaluate clinical, microbiological, and pharmacological outcomes before and after the implementation of an ASP in the Vascular Surgery ward of Fondazione IRCCS Policlinico San Matteo, a tertiary care hospital in Pavia, Italy.

Methods: This was a quasi-experimental quality-improvement study.

View Article and Find Full Text PDF

Background: This guideline (GL) on carotid surgery as updating of "Stroke: Italian guidelines for Prevention and Treatment" of the ISO-SPREAD Italian Stroke Organization-Group, has recently been published in the National Guideline System and shared with the Italian Society of Vascular and Endovascular Surgery (SICVE) and other Scientific Societies and Patient's Association.

Methods: GRADE-SIGN version, AGREE quality of reporting checklist. Clinical questions formulated according to the PICO model.

View Article and Find Full Text PDF

Background And Aim: Spinal cord ischemia following open or endovascular aneurysm repair of the abdominal aorta is rare but highly disabling complication. The aim of this work is to report on its occurrence and its legal consequences.

Methods: We report a case of spinal cord ischemia complicating an endovascular aortic repair, its management and sequalae, comparing it with the existing literature and we examine its legal consequences resulting in a malpractice lawsuit and the final decision of the judge.

View Article and Find Full Text PDF

Background: This study aims to propose a minimally invasive surgical approach to the common femoral artery in endovascular aortic repair and assess its value by a single-center retrospective study including 118 patients.

Methods: Between 2017 and 2022, all patients receiving endovascular treatment for thoracic and abdominal aortic aneurysms in our center had the anterior wall of the common femoral artery exposed, through a 2-3 cm transverse groin incision, instead of a complete surgical cutdown. We access the artery with a purse-string suture, held tight with a tourniquet.

View Article and Find Full Text PDF

Objectives: The aim of the study was to assess 24-month efficacy and safety of a novel drug-eluting stent (DES) for femoropopliteal interventions with an innovative stent design and abluminal reservoir technology releasing the amphilimus formulation (sirolimus plus fatty acid) for efficient drug transfer and optimized release kinetics.

Background: DES releasing paclitaxel exhibited good patency rates after femoropopliteal interventions. No benefit has been reported when sirolimus or everolimus were used for antiproliferative stent coating.

View Article and Find Full Text PDF

Background: The liability of patients affected by novel coronavirus disease (COVID-19) to develop venous thromboembolic events is widely acknowledged. However, many particulars of the interactions between the two diseases are still unknown. This study aims to outline the main characteristics of deep venous thrombosis (DVT) and pulmonary embolism (PE) in COVID-19 patients, based on the experience of four high-volume COVID-19 hospitals in Northern Italy.

View Article and Find Full Text PDF
Reply.

J Vasc Surg Venous Lymphat Disord

September 2020

View Article and Find Full Text PDF

The aim of this report is to discuss emergent repair for complex aortic diseases in patients affected by novel coronavirus pneumonia (coronavirus disease-2019 [COVID-19]), describing a case of ruptured pararenal aortic aneurysm. An eighty-year-old man with COVID-19 was admitted for ruptured aneurysm of the pararenal aorta and hemorrhagic shock. Endovascular repair was chosen, and a proximal extension of the previous abdominal endograft was performed with parallel stents in the right renal artery and the superior mesenteric artery.

View Article and Find Full Text PDF

Objectives: Open repair is still the first choice for thoraco-abdominal and para-renal aortic aneurysms, but surgical treatment is burdened by significant morbidity and mortality, especially in urgent setting. Endovascular treatment by fenestrated or branched endografts is feasible and safe; but in urgent/emergent settings, custom-made endografts are hardly available in due time, and the repair with standard multibranched devices is still debated in cases with complex anatomy. Parallel grafting, on the other hand, which exploits covered stents to preserve patency of the visceral vessels, has been shown as a valuable option and can be performed in urgency, though some concerns still remain regarding its durability and complications.

View Article and Find Full Text PDF

Background: Splenic artery aneurysms are rare, but their occurrence is burdened by considerable mortality and morbidity rates. Although the indications to treatment are quite clear-cut, there is still debate on the first-choice technique of treatment (endovascular, open, or laparoscopic surgery). Recently, robotic surgery has been proposed as an alternative option in patients at high surgical risk.

View Article and Find Full Text PDF

Background: Open conversion of endovascular aortic repair (EVAR) is the first-choice treatment in case of endograft failure or high-flow endoleak. However, the traditional technique based on the total removal of the endograft can produce injuries of the aortic walls, with severe consequences on the anastomoses quality. Our aim is to show the advantages of the partial endograft removal on the aortic integrity by reporting a case series including 25 delayed open conversion performed with this technique.

View Article and Find Full Text PDF