Aim: A recent European Heart Rhythm Association (EHRA) practical guide provides guidance on the use of novel digital devices for heart rhythm analysis using either electrocardiogram (ECG) or photoplethysmography (PPG) technology for the diagnosis of atrial fibrillation (AF). This survey assesses physicians' preferences to use digital devices in patients with possible AF and their impact on clinical decision-making.
Methods And Results: Participants of the DAS-CAM III initiated and distributed an online survey assessing physician preferences in using digital devices for the management of AF in different clinical scenarios.
Pacing Clin Electrophysiol
December 2024
Persistent left superior vena cava (PLSVC) is one of the anatomical variations, which can make device implantation more challenging and lead to incorrect lead placement, dislodgement, and procedure failure. Conduction system pacing (CSP) can be an alternative to traditional CRT implantation. Herein, we describe a brief case report of successful LBBAP-optimized CRT (LOT-CRT) via an innominate vein in a patient with PLSVC.
View Article and Find Full Text PDFEuropace
July 2024
J Innov Card Rhythm Manag
January 2024
Pacing-induced cardiomyopathy (PICM) is defined as a drop in left ventricular ejection fraction (LVEF) in the setting of chronic, high-burden right ventricular pacing. Cardiac resynchronization therapy (CRT) and conduction system pacing (CSP) have been proposed to manage PICM. Although acute myocardial infarction has been described as a predictor of PICM, there are no guideline recommendations for CRT or CSP in patients with coronary artery disease (CAD) and preserved LVEF.
View Article and Find Full Text PDFA 58-year-old man admitted for a cryoballoon ablation due to a history of symptomatic paroxysmal atrial fibrillation experienced pericardial effusion and cardiac tamponade intraoperatively. A longitudinal left superior pulmonary vein perforation was confirmed by emergency thoracotomy and repaired. He developed atrial fibrillation 2 days postoperatively, which was terminated with colchicine and oral steroids the following day.
View Article and Find Full Text PDFBrugada phenocopy (BrP) is a clinical condition characterized by transient ECG changes of Brugada syndrome (BrS), which can be due to various clinical conditions. We describe a case report of BrP due to psychotic drugs.
View Article and Find Full Text PDFMyocarditis is an inflammatory disease of the myocardium with a wide range of potential etiological factors, including a variety of infectious agents (mainly viral), systemic diseases, drugs, and toxins.
View Article and Find Full Text PDFLeft ventricular lead positioning is technically demanding in cardiac resynchronization therapy (CRT) device implantation, especially in patients with complex cardiac venous anatomies. We report a case in which retrograde snaring was employed to successfully deliver the left ventricular lead through a persistent left superior vena cava for CRT implantation.
View Article and Find Full Text PDFBrugada phenocopies (BrP) represent electrocardiogram changes identical to those of true congenital Brugada syndrome but are induced by reversible clinical conditions. Previous cases have been reported in patients following recreational drug use. This report presents two cases of type 1B BrP associated with Fenethylline abuse, a recreational drug known by its trade name, Captagon.
View Article and Find Full Text PDFBackground: The reported success rate of His-bundle pacing (HBP) in patients with infranodal atrioventricular (AV) conduction disease is only 52%-76%. The success rate of left bundle branch area pacing (LBBAP) in this cohort is not well studied.
Objective: The purpose of this study was to evaluate the feasibility, safety, and electrophysiological characteristics of LBBAP in patients with AV conduction disease.
Background: Ablation index (AI) is a novel catheter-based parameter that has improved the outcome and safety of radiofrequency (RF) ablation of pulmonary vein isolations (PVIs). This index incorporates contact force (CF) (g), time (s), and power (W) parameters. The role of AI in redo ablations for persistent atrial fibrillation (peAF) has not been fully investigated.
View Article and Find Full Text PDFLeadless pacemakers have become an effective alternative to conventional transvenous pacemakers to prevent the risk of lead failure, pocket complications, and iatrogenic tricuspid regurgitation. The current transcatheter approach for tricuspid valve repair can limit the implantation of these devices, unless the procedure is performed with appropriate image guidance. We present the case of a patient with severe tricuspid regurgitation secondary to pacemaker lead impingement who, despite the implantation of a tricuspid clip, received a leadless pacemaker.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
September 2021
Objectives: To evaluate the safety and feasibility of left bundle branch area pacing (LBBAP) in patients with valvular interventions.
Methods: Eighty-four patients were included in this study. All patients underwent recent surgical or percutaneous valvular interventions.
Accessory pathways (APs) are commonly located around the tricuspid and mitral annulus; however, they can be rarely seen in unusual locations like the aortomitral continuity (AMC), the right atrium to the right ventricular outflow region, and the left atrial appendage to left ventricle connection. Although several electrocardiogram algorithms have been proposed to localize the AP, the sensitivity of these algorithms is not high and they may fail to localize the mentioned unusual localizations. In this report, we describe a case of a 37-year-old man presenting with an AP originating from the AMC, which was successfully ablated.
View Article and Find Full Text PDFAtrial fibrillation (AF) ablation has been shown to be an effective treatment for AF, although our understanding of AF ablation outcomes until now, has been based on AF recurrence as a dichotomous variable. Reduction in AF burden, defined as the proportion of time that an individual is in AF during a monitoring period, has been already correlated to an improvement in quality of life and is likely a better assessment of success. Clinically, many patients may still have a few short recurrences of AF but feel much better.
View Article and Find Full Text PDFBackground: Coronavirus disease 2019 (COVID-19) primarily causes lung infection, but recent studies have shown that cardiac involvement is associated with a worse prognosis.
Objectives: We conducted a systematic review and meta-analysis to examine the prevalence of cardiac arrhythmias detected by the electrocardiogram and their relationships with adverse outcomes in patients with COVID-19.
Methods: PubMed and Google were searched for studies that reported on cardiac arrhythmias and/or examined the relationship between arrhythmias and adverse outcomes.
Objectives: This multicenter registry aimed to assess the reproducibility and safety of intentional coronary vein exit and carbon dioxide insufflation to facilitate subxiphoid epicardial access in the setting of ventricular tachycardia ablation.
Background: Epicardial ablation for ventricular tachycardia is not a widespread technique due to the significant potential complications associated with subxiphoid puncture. The first experience in 12 patients showed that intentional coronary vein exit and carbon dioxide insufflation was technically feasible.
In December 2019, reports of an unknown pneumonia not responsive to traditional treatments arose in Wuhan, China. The pathogen was subsequently identified as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), known to be responsible for the coronavirus disease-2019 (COVID-19) illness, and public health emergency of international concern was declared by the World Health Organization. There is increasing awareness of the cardiovascular manifestations of COVID-19 disease, and the adverse impact of cardiovascular involvement on its prognosis.
View Article and Find Full Text PDFPacing Clin Electrophysiol
October 2020
Left bundle branch block (LBBB) can result in significant dyssynchrony in left ventricular (LV) contraction, ultimately leading to cardiac remodeling. LBBB can be rate dependent and may appear with LV systolic dysfunction. Cardiac resynchronization therapy (CRT) has been demonstrated to improve hemodynamics as well as clinical symptoms in patients with LBBB.
View Article and Find Full Text PDFLeadless pacemakers provide a potential alternative to conventional transvenous pacemakers for patients undergoing high-risk transcatheter valve replacement procedures. This is a description of a successful leadless pacemaker implantation in a 51-year-old woman who developed profound bradycardia following a transcatheter aortic valve replacement and mitral valve-in-valve procedure.
View Article and Find Full Text PDFLeft septal fascicular block, or blockage of the middle fibers of the left bundle branch, is known to be suggestive of a critical proximal obstruction of the left anterior descending coronary artery before its first septal perforator branch. We describe the case of a 68-year-old male who exhibited this transient intraventricular dromotropic disturbance following alcohol septal ablation for hypertrophic obstructive cardiomyopathy.
View Article and Find Full Text PDFBACKGROUND The occurrence of ventricular arrhythmias (VAs), particularly premature ventricular complexes, following pulmonary vein isolation (PVI) is a documented phenomenon, but monomorphic scar-related ventricular tachycardia (VT) following PVI is an unusual phenomenon. In this case report, we present a case of new-onset VA after radiofrequency PVI in a patient with no prior history of sustained VTs. CASE REPORT Our patient was a 69-year-old man with a history of symptomatic persistent atrial fibrillation, with an apparently structurally normal heart with subtle regional wall motion abnormalities.
View Article and Find Full Text PDF