Core-spun yarn (CSY) is utilized for better fabric characteristics like stretchability, durability, and comfortability. The study aims to investigate the influence of spandex drafts of core-spun yarn on denim fabric characteristics before and after washing treatment. Two types of denim fabrics were produced from two types of core-spun yarn, namely 16 + 40D, and 16 + 70D by applying 2.
View Article and Find Full Text PDFChlorpyrifos (CPF) [O, O-diethyl -O-3, 5, 6-trichloro-2-pyridyl phosphorothioate] is an organophosphate insecticide widely used for agricultural and urban pest control. Trichloropyridinol (TCP; 3,5,6-trichloro-2-pyridinol), the primary metabolite of CPF, is often used as a generic biomarker of exposure for CPF and related compounds. Human embryonic kidney 293 (HEK 293) cells were exposed to CPF and TCP with varying concentrations and exposure periods.
View Article and Find Full Text PDFThe Agrochemicals Division cosponsored the 13th International Union of Pure and Applied Chemistry International Congress of Pesticide Chemistry held as part of the 248th National Meeting and Exposition of the American Chemical Society in San Francisco, CA, USA, August 10-14, 2014. The topic of the Congress was Crop, Environment, and Public Health Protection; Technologies for a Changing World. Over 1000 delegates participated in the Congress with interactive scientific programming in nine major topic areas including the challenges and opportunities of agricultural biotechnology.
View Article and Find Full Text PDFTo provide sufficient food and fiber to the increasing global population, the technologies associated with crop protection are growing ever more sophisticated but, at the same time, societal expectations for the safe use of crop protection chemistry tools are also increasing. The goal of this perspective is to highlight the key issues that face future leaders in crop protection, based on presentations made during a symposium titled "Developing Global Leaders for Research, Regulation and Stewardship of Crop Protection Chemistry in the 21st Century", held in conjunction with the IUPAC 13th International Congress of Pesticide Chemistry in San Francisco, CA, USA, during August 2014. The presentations highlighted the fact that leaders in crop protection must have a good basic scientific training and understand new and evolving technologies, are aware of the needs of both developed and developing countries, and have good communication skills.
View Article and Find Full Text PDFA selective pressurized liquid extraction (SPLE) method was developed for a streamlined sample preparation/cleanup to determine Aroclors and coplanar polychlorinated biphenyls (PCBs) in soil and sediment. The SPLE was coupled with an enzyme-linked immunosorbent assay (ELISA) for an effective analytical approach for environmental monitoring. Sediment or soil samples were extracted with alumina, 10% AgNO3 in silica, and sulfuric acid impregnated silica with dichloromethane at 100°C and 2000 psi.
View Article and Find Full Text PDFAn efficient and reliable analytical method was developed for the sensitive and selective quantification of pyrethroid pesticides (PYRs) in house dust samples. The method is based on selective pressurized liquid extraction (SPLE) of the dust-bound PYRs into dichloromethane (DCM) with analysis by gas chromatography/mass spectrometry. Various adsorbents and combinations of extraction solvents and temperatures were evaluated to achieve a high-throughput sample preparation that eliminates the post-extraction cleanup step.
View Article and Find Full Text PDFAn immunoaffinity chromatography (IAC) column was developed as a simple cleanup procedure for preparing environmental samples for analysis of polychlorinated biphenyls (PCBs). Soil and sediment samples were prepared using pressurized liquid extraction (PLE), followed by the IAC cleanup, with detection by an enzyme-linked immunosorbent assay (ELISA). Quantitative recoveries (84-130%) of PCB-126 were obtained in fortified sediment and soil samples using the PLE/IAC/ELISA method.
View Article and Find Full Text PDFDevelopment of a multianalyte enzyme-linked immunosorbent assay (ELISA) for detection of permethrin and aroclors 1248 or 1254 and implementation of the assay for analysis of soil/sediment samples are described. The feasibility of using the multianalyte ELISA to monitor aroclors 1254 and permethrin simultaneously was tested with permethrin and aroclor standards and with aroclor- and permethrin-containing soil/sediment and house dust samples. Comparison of the I₅₀ and I₂₀ values of the multianalyte with those of a single-analyte assay revealed similar results, and multianalyte ELISA determination of analyte amounts in soil/sediment dust samples yielded similar results to those of a single-analyte assay.
View Article and Find Full Text PDFFoods are complex mixtures of lipids, carbohydrates, proteins, vitamins, organic compounds, and other naturally occurring substances. Sometimes added to this mixture are residues of pesticides, veterinary and human drugs, microbial toxins, preservatives, contaminants from food processing and packaging, and other residues. This milieu of compounds can pose difficulties in the analysis of food contaminants.
View Article and Find Full Text PDFAn enzyme-linked immunosorbent assay (ELISA) method was employed for determination of the pyrethroid biomarker, 3-phenoxybenzoic acid (3-PBA) in human urine samples. The optimized coating antigen concentration was 0.5 ng/mL with a dilution of 1:4000 for the 3-PBA antibody and 1:6000 for the enzyme conjugate.
View Article and Find Full Text PDFTwo polychlorinated biphenyls (PCB) enzyme linked immunosorbent assays (ELISAs) were developed using goat PCB purified immunoglobulin (IgG) antibodies (Abs). The IgGs exhibited the highest affinity toward PCB-77 (24 ng mL(-1)) with sensitivities in the range of 6-11 ng mL(-1). The Abs cross-reacted with PCB-126 and the heptachlorodibenzofuran 1,2,3,4,6,7,8-HpCDF but not with PCB-169, PCB-118, Aroclor 1232, 1248, 1260 or the hexachlorodibenzofuran 2,3,4,6,7,8-HxCDF.
View Article and Find Full Text PDFA low-cost, high throughput bioanalytical screening method was developed for monitoring cis/trans-permethrin in dust and soil samples. The method consisted of a simple sample preparation procedure [sonication with dichloromethane followed by a solvent exchange into methanol:water (1:1)] with bioanalytical detection using a magnetic particle enzyme-linked immunosorbent assay (ELISA). Quantitative recoveries (83-126%) of cis/trans-permethrin were obtained for spiked soil and dust samples.
View Article and Find Full Text PDFA high-throughput screening method using selective pressurized liquid extraction (SPLE) and enzyme-linked immunosorbent assay (ELISA) for monitoring dioxins in sediment and soil is described. SPLE conditions were developed by extracting sediment or soil together with alumina, 10% AgNO3 in silica, and sulfuric acid impregnated silica (acid silica) using dichloromethane (DCM) as the solvent at 100 degrees C and 2000 psi. Post-extraction cleanups were not required for ELISA.
View Article and Find Full Text PDFAn enzyme-linked immunosorbent assay (ELISA) method was developed to quantitatively measure 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine. Samples were diluted (1:5) with phosphate-buffered saline containing 0.05% Tween and 0.
View Article and Find Full Text PDFPolychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are considered highly toxic contaminants and the environmental and biological monitoring of these compounds is of great concern. Immunoassays may be used as screening methods to satisfy the growing demand for rapid and low cost analysis. In this work, we describe the application of an immunoassay that uses 2,3,7-trichloro-8-methyldibenzo-p-dioxin (TMDD) as a surrogate standard for 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) to sediment and human serum samples.
View Article and Find Full Text PDFA 96-microwell enzyme-linked immunosorbent assay (ELISA) method was evaluated to determine PCDDs/PCDFs in sediment and soil samples from an EPA Superfund site. Samples were prepared and analyzed by both the ELISA and a gas chromatography/high resolution mass spectrometry (GC/HRMS) method. Comparable method precision, accuracy, and detection level (8 ng kg(-1)) were achieved by the ELISA method with respect to GC/HRMS.
View Article and Find Full Text PDFA rabbit antibody immunoaffinity (IA) column procedure was evaluated as a cleanup method for the determination of atrazine in soil, sediment, and food. Four IA columns were prepared by immobilizing a polyclonal rabbit anti-atrazine antibody solution to HiTrap Sepharose columns. Atrazine was bound to the IA columns when the loading solvents were either 100% water, 2% acetonitrile in water, or 10% methanol in phosphate buffered saline (PBS).
View Article and Find Full Text PDFEnzyme-linked immunosorbent assay (ELISA) and sol-gel-based immunoaffinity purification (IAP) methods for the pyrethroid bioallethrin were developed and applied for monitoring bioallethrin in spiked food, soil, and dust samples. Attempts to determine bioallethrin content in fruit and vegetable extracts revealed high variability between sample preparations and marked interferences with the assay. Sol-gel IAP followed by solid-phase sample concentration was effective in removing the interfering components and resulted in high recovery of bioallethrin from spiked crude acetonic extracts of fruits and vegetables, even in the presence of high extract concentrations (28%).
View Article and Find Full Text PDFBull Environ Contam Toxicol
March 2006
The goal of this research was to develop a measurable indicator of human exposure to Stachyborys chartarum. Antibodies were produced against the hemolytic agent stachylysin obtained from the mold S. chartarum.
View Article and Find Full Text PDFImmunochemical methods are based on selective antibodies combining with a particular target analyte or analyte group. The specific binding between antibody and analyte can be used to detect environmental contaminants in a variety of sample matrixes. Immunoassay methods provide cost-effective, sensitive, and selective analyses for many compounds of environmental and human health concern.
View Article and Find Full Text PDFLimited by the lack of a sensitive, universal detector, many capillary-based liquid-phase separation techniques might benefit from techniques that overcome modest concentration sensitivity by preconcentrating large injection volumes. The work presented employs selective solid-phase extraction by immunoaffinity capillary electrochromatography (IACEC) to enhance detection limits. A model analyte, fluorescein isothiocyanate (FITC) biotin, is electrokinetically applied to a capillary column packed with an immobilized anti-biotin-IgG support.
View Article and Find Full Text PDF