Continuous oxygenation monitoring of machine-perfused organs or transposed autologous tissue is not currently implemented in clinical practice. Oxygenation is a critical parameter that could be used to verify tissue viability and guide corrective interventions, such as perfusion machine parameters or surgical revision. This work presents an innovative technology based on oxygen-sensitive, phosphorescent metalloporphyrin allowing continuous and non-invasive oxygen monitoring of ex-vivo perfused vascularized fasciocutaneous flaps.
View Article and Find Full Text PDFIntegration of physiological sensing modalities within tissue and organ perfusion systems is becoming a steadily expanding field of research, aimed at achieving technological breakthrough innovations that will expand the sites and clinical settings at which such systems can be used. This is becoming possible in part due to the advancement of user-friendly optical sensors in recent years, which rely both on synthetic, luminescent sensor molecules and inexpensive, low-power electronic components for device engineering. In this article we report a novel approach towards enabling automated, continuous monitoring of oxygenation during organ perfusion, by combining versatile flow cell components and low-power, programmable electronic readout devices.
View Article and Find Full Text PDFOxygenation is a crucial indicator of tissue viability and function. Oxygen tension ([Formula: see text]), i.e.
View Article and Find Full Text PDFContinuously monitoring transcutaneous CO partial pressure is of crucial importance in the diagnosis and treatment of respiratory and cardiac diseases. Despite significant progress in the development of CO sensors, their implementation as portable or wearable devices for real-time monitoring remains under-explored. Here, we report on the creation of a wearable prototype device for transcutaneous CO monitoring based on quantifying the fluorescence of a highly breathable CO-sensing film.
View Article and Find Full Text PDFSensor-integrated wound dressings are emerging tools applicable to a wide variety of medical applications from emergency triage to at-home monitoring. Uncomfortable, unnecessary wound dressing changes may be avoided by providing quantitative insight into tissue characteristics related to wound healing such as tissue oxygenation, pH, and exudate/transudate volume. Here, a simple cost-effective methodology for quantifying oxygen and pH in a swellable hydrogel dressing using a single photograph is presented.
View Article and Find Full Text PDFBiomed Opt Express
December 2020
Wearable devices have found widespread applications in recent years as both medical devices as well as consumer electronics for sports and health tracking. A metric of health that is often overlooked in currently available technology is the direct measurement of molecular oxygen in living tissue, a key component in cellular energy production. Here, we report on the development of a wireless wearable prototype for transcutaneous oxygenation monitoring based on quantifying the oxygen-dependent phosphorescence of a metalloporphyrin embedded within a highly breathable oxygen sensing film.
View Article and Find Full Text PDFFlaps are common in plastic surgery to reconstruct large tissue defects in cases such as trauma or cancer. However, most tissue oximeters used for monitoring ischemia in postoperative flaps are bulky, wired devices, which hinder direct flap observation. Here, we present the results of a clinical trial using a previously untried paintable transparent phosphorescent bandage to assess the tissue's partial pressure of oxygen (pO).
View Article and Find Full Text PDFMeasurement of intramuscular oxygen could play a key role in the early diagnosis of acute compartment syndrome, a common condition occurring after severe trauma leading to ischemia and long-term consequences including rhabdomyolysis, limb loss, and death. However, to date, there is no existing oxygen sensor approved for such a purpose. To address the need to improve the assessment of compartment syndrome, a portable fiber-optic device for intramuscular oxygen measurements was developed.
View Article and Find Full Text PDFQuantification of tissue oxygen partial pressure (pO ) at the skin surface is crucial for diagnostic applications in burns, reconstructive surgeries, diabetic ulcers, etc. Further, current advances in wearable and communications technologies have widened the use of transcutaneous oxygen monitors (TCOM) for home care or even enhance athletic performance. For TCOM technology to find widespread use, devices must function reliably yet independently of changes in environmental conditions, humidity in particular.
View Article and Find Full Text PDFAcute and chronic wounds affect millions and are associated with billions of dollars in healthcare costs. The use of healing markers, biochemical cues from biocompatible matrices and materials, and their correlation with wound healing has the potential to generate valuable diagnostic, prognostic, and therapeutic information. In this study, we developed a collagen-dextran oxygen-sensing biocomposite scaffold membrane in which a phosphorescent oxygen sensor was incorporated to monitor physiological oxygen using in vivo phosphorescence imaging in a preclinical mouse model of wound healing.
View Article and Find Full Text PDFInternal bleeding is an injury that can be difficult to localize and effectively treat without invasive surgeries. Injectable polymeric nanoparticles have been developed that can reduce clotting times and blood loss, but they have yet to incorporate sufficient diagnostic capabilities to assist in identifying bleeding sources. Herein, polymeric nanoparticles were developed to simultaneously treat internal bleeding while incorporating tracers for visualization of the nanoparticles by standard clinical imaging modalities.
View Article and Find Full Text PDFBackground: Knowledge of tissue oxygenation status is fundamental in the prevention of postoperative flap failure. Recently, the authors introduced a novel oxygen-sensing paint-on bandage that incorporated an oxygen-sensing porphyrin with a commercially available liquid bandage matrix. In this study, the authors extend validation of their oxygen-sensing bandage by comparing it to the use of near-infrared tissue oximetry in addition to Clark electrode measurements.
View Article and Find Full Text PDFThe cerebral metabolic rate of oxygen ([Formula: see text]) is an essential parameter for evaluating brain function and pathophysiology. However, the currently available approaches for quantifying [Formula: see text] rely on complex multimodal imaging and mathematical modeling. Here, we introduce a method that allows estimation of [Formula: see text] based on a single measurement modality-two-photon imaging of the partial pressure of oxygen ([Formula: see text]) in cortical tissue.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
December 2015
A new group of "clickable" and brightly emissive metalloporphyrins has been developed for the visualization of oxygenation under ambient light with the naked eye. These alkynyl-terminated compounds permit the rapid and facile synthesis of oxygen-sensing dendrimers through azide-alkyne click chemistry. With absorption maxima overlapping with the wavelengths of common commercial laser sources, they are readily applicable to biomedical imaging of tissue oxygenation.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
July 2015
Oxygen monitoring has been a topic of exhaustive study given its central role in the biochemistry of life. The ability to quantify the physiological distribution and real-time dynamics of oxygen from sub-cellular to macroscopic levels is required to fully understand the mechanisms associated with both normal physiology and disease states. This Review will present the most significant recent advances in the development of oxygen-sensing materials and techniques, including polarographic, nuclear medicine, magnetic resonance, and optical approaches, that can be applied specifically for the real-time monitoring of oxygen dynamics in cellular and tissue environments.
View Article and Find Full Text PDFOxygen plays an important role in wound healing, as it is essential to biological functions such as cell proliferation, immune responses and collagen synthesis. Poor oxygenation is directly associated with the development of chronic ischemic wounds, which affect more than 6 million people each year in the United States alone at an estimated cost of $25 billion. Knowledge of oxygenation status is also important in the management of burns and skin grafts, as well as in a wide range of skin conditions.
View Article and Find Full Text PDFRecent development of two-photon phosphorescence lifetime microscopy (2PLM) of oxygen enabled first noninvasive high-resolution measurements of tissue oxygenation in vivo in 3D, providing valuable physiological information. The so far developed two-photon-enhanced phosphorescent probes comprise antenna-core constructs, in which two-photon absorbing chromophores (antenna) capture and channel excitation energy to a phosphorescent core (metalloporphyrin) via intramolecular excitation energy transfer (EET). These probes allowed demonstration of the methods' potential; however, they suffer from a number of limitations, such as partial loss of emissivity to competing triplet state deactivation pathways (e.
View Article and Find Full Text PDFHypoxia is an important contributing factor to the development of drug-resistant cancer, yet few nonperturbative tools exist for studying oxygenation in tissues. While progress has been made in the development of chemical probes for optical oxygen mapping, penetration of such molecules into poorly perfused or avascular tumor regions remains problematic. A click-assembled oxygen-sensing (CAOS) nanoconjugate is reported and its properties demonstrated in an in vitro 3D spheroid cancer model.
View Article and Find Full Text PDFCharacterization of how the microenvironment, or niche, regulates stem cell activity is central to understanding stem cell biology and to developing strategies for the therapeutic manipulation of stem cells. Low oxygen tension (hypoxia) is commonly thought to be a shared niche characteristic in maintaining quiescence in multiple stem cell types. However, support for the existence of a hypoxic niche has largely come from indirect evidence such as proteomic analysis, expression of hypoxia inducible factor-1α (Hif-1α) and related genes, and staining with surrogate hypoxic markers (for example, pimonidazole).
View Article and Find Full Text PDFA major challenge in creating and optimizing therapeutics in the fight against cancer is visualizing and understanding the microscale spatiotemporal treatment response dynamics that occur in patients. This is especially true for photodynamic therapy (PDT), where therapeutic optimization relies on understanding the interplay between factors such as photosensitizer localization and uptake, in addition to light dose and delivery rate. In vitro 3D culture systems that recapitulate many of the biological features of human disease are powerful platforms for carrying out detailed studies on PDT response and resistance.
View Article and Find Full Text PDFIn vivo imaging of cerebral tissue oxygenation is important in defining healthy physiology and pathological departures associated with cerebral disease. We used a recently developed two-photon microscopy method, based on a novel phosphorescent nanoprobe, to image tissue oxygenation in the rat primary sensory cortex in response to sensory stimulation. Our measurements showed that a stimulus-evoked increase in tissue pO₂ depended on the baseline pO₂ level.
View Article and Find Full Text PDFUncovering principles that regulate energy metabolism in the brain requires mapping of partial pressure of oxygen (PO(2)) and blood flow with high spatial and temporal resolution. Using two-photon phosphorescence lifetime microscopy (2PLM) and the oxygen probe PtP-C343, we show that PO(2) can be accurately measured in the brain at depths up to 300 μm with micron-scale resolution. In addition, 2PLM allowed simultaneous measurements of blood flow and of PO(2) in capillaries with less than one-second temporal resolution.
View Article and Find Full Text PDFMonitoring of the spatiotemporal characteristics of cerebral blood and tissue oxygenation is crucial for better understanding of the neuro-metabolic-vascular relationship. Development of new pO2 measurement modalities with simultaneous monitoring of pO2 in larger fields of view with higher spatial and/or temporal resolution will enable greater insight into the functioning of the normal brain and will also have significant impact on diagnosis and treatment of neurovascular diseases such as stroke, Alzheimer's disease, and head injury. Optical imaging modalities have shown a great potential to provide high spatiotemporal resolution and quantitative imaging of pO2 based on hemoglobin absorption in visible and near infrared range of optical spectrum.
View Article and Find Full Text PDFMeasurements of oxygen partial pressure (pO(2)) with high temporal and spatial resolution in three dimensions is crucial for understanding oxygen delivery and consumption in normal and diseased brain. Among existing pO(2) measurement methods, phosphorescence quenching is optimally suited for the task. However, previous attempts to couple phosphorescence with two-photon laser scanning microscopy have faced substantial difficulties because of extremely low two-photon absorption cross-sections of conventional phosphorescent probes.
View Article and Find Full Text PDFOxygen concentration distributions in biological systems can be imaged by the phosphorescence quenching method in combination with two-photon laser scanning microscopy. In this paper, we identified the excitation regime in which the signal of a two-photon-enhanced phosphorescent probe (Finikova, O. S.
View Article and Find Full Text PDF