Purpose: The objective of this study was to compare the capacity of anterior segment optical coherence tomography (AS-OCT) and Scheimpflug camera in detecting tomographic changes over 1 year in a cohort of patients with Fuchs endothelial corneal dystrophy.
Methods: We conducted a single-center prospective study which consisted of 2 identical visits spaced 1 year apart. At each visit, tomographic analyses were performed using Scheimpflug imaging (Pentacam HR, Oculus) and swept source AS-OCT (Casia SS-1000 Tomey).
Purpose: To determine whether the clinical and paraclinical course of Fuchs endothelial corneal dystrophy (FECD) over 1 year is related to the extent of triplet repetition in the transcription factor 4 (TCF4) gene.
Methods: A prospective study with a 1-year follow-up was conducted. A total of 104 patients (160 eyes) with FECD and an equivalent number of age- and sex-matched control subjects without FECD were included.
Eye drops containing steroids and antibiotics are widely used to treat a large range of ocular diseases of the ocular surface. They require frequent instillation or a high dosage, which can affect quality of life. We developed a biomaterial from human umbilical cord that can be loaded with drugs before being placed in the inferior conjunctival fornix.
View Article and Find Full Text PDFCorneal epithelial barrier represents one of the major limitations to ocular drug delivery and can be explored non-invasively through the evaluation of its electrical properties. Human corneas stored in active storage machine (ASM) could represent an interesting physiological model to explore transcorneal drug penetration. We designed a new system adapted to human corneas preserved in ASM to explore corneal epithelial barrier function ex-vivo.
View Article and Find Full Text PDFPurpose: Unlike corneas stored in cold storage (CS) which remain transparent and thin, corneas stored in organoculture (OC) cannot be assessed by specular microscopy (SM), because edema and posterior folds occur during storage and prevent from specular reflection. We previously developed an active storage machine (ASM) which restores the intraocular pressure while renewing the storage medium, thus preventing major stromal edema. Its transparent windows allow multimodal corneal imaging in a closed system.
View Article and Find Full Text PDFPurpose: To report a detailed surgical procedure of tissue engineered endothelial keratoplasty (TEEK) in a rabbit model and its postoperative evaluation.
Methods: TEEKs were prepared 7 days before transplantation by seeding human or rabbit corneal endothelial cells on either femtosecond laser-cut ultrathin human stromal lamellae (fs-UTSL) or femtosecond laser-cut human anterior lens capsule (fs-HALC). Thirty transplantations were performed on aphakic eyes.
Purpose: To develop a method to label proliferating corneal endothelial cells (ECs) in rabbits in vivo and track their migration over time.
Methods: We compared intraperitoneal (IP) and intracameral (IC) administration of 5-ethynyl-2'-deoxyuridine (EdU) in two experiments: (1) six rabbits received IP or IC EdU. Blood and aqueous humor (AH) samples were incubated with HL-60 cells.
Background/aim: Rejection is the main cause of graft failure after penetrating keratoplasty (PK). Its prevention by repeated instillation of steroid eye-drops has not evolved in decades. Poor adherence and discontinuous nature of eye-drop treatment may explain some PK failures.
View Article and Find Full Text PDFTransl Vis Sci Technol
February 2021
Purpose: To characterize the corneal epithelium (CE) and limbal epithelium (LE) of human corneas stored in an innovative active storage machine (ASM) after a period of organ culture (OC).
Methods: Corneas unsuitable for graft and stored in a standard commercial OC medium for 2 to 5 weeks were transferred into our ASM for 14 days. The ASM actively maintained an overpressure on the endothelial side (20 mm Hg) while ensuring medium renewal.
Background: Corneal storage for the very long term, without degradation, would make it possible to optimize a very limited resource worldwide. We previously demonstrated the superiority, compared to conventional 4-week passive organ culture (OC), of an active storage machine (ASM) that restores intraocular pressure and medium renewal. Here, we investigate eye banking for up to 3 months.
View Article and Find Full Text PDFOptimal ex vivo corneal storage in eye banks is crucial to increase both the number of corneas suitable for graft and their intrinsic quality, mainly the number of viable endothelial cells, which dictates graft survival in recipients. With both passive storage methods used worldwide (short-term cold storage in the United States, long-term organ culture in Europe), significant endothelial cell loss is inevitable. Here we show that, with an active storage machine, also called a bioreactor, which restores 2 fundamental physiological parameters, intraocular pressure and medium renewal, endothelial cell survival is improved by 23% compared with organ culture after 4 weeks' storage.
View Article and Find Full Text PDFObjectives: Complete epithelial wound healing is a milestone in early postoperative care after penetrating keratoplasty. The re-epithelialization rate after penetrating keratoplasty was measured in patients receiving a new matrix therapy agent (regenerating agent, Cacicol) that mimics heparan sulphates.
Methods: This was a prospective, open-label, uncontrolled, single-centre observational study.
Aims: To evaluate the efficacy of a subconjunctival dexamethasone-releasing implant in preventing rejection of penetrating keratoplasty (PK) in an animal model.
Methods: Twenty-two rabbits underwent allogenic PK. After randomisation, they received either a 700 µg dexamethasone implant under the conjunctiva at the end of surgery (n=10), one dexamethasone 1 mg/mL eye-drop thrice daily (n=6) or a placebo thrice daily (n=6).
Purpose: To quantify cell survival and tissue structure preservation of porcine cornea stored in a bioreactor (BR) that recreates a transcorneal pressure gradient equivalent to intraocular pressure (IOP) and renews the medium.
Methods: A BR comprising endothelial and epithelial chambers was machined in a biocompatible material. The porcine cornea, securely held, separated the chambers.