Publications by authors named "Emmanuel Christodoulou"

Rabies reemerged in Greek fauna during October 2012, 25 years after the last report in animals and 42 after the last human case. This study examined the administration of rabies postexposure prophylaxis (PEP) in humans over the period 2012-2016. A total of 1,454 individuals (62.

View Article and Find Full Text PDF

Purpose: To report dosimetry of commonly performed interventional radiology procedures and compare dose analogues to known reference levels.

Materials And Methods: Demographic and dosimetry data were collected for gastrostomy, nephrostomy, peripherally inserted central catheter placement, visceral arteriography, hepatic chemoembolization, tunneled catheter placement, inferior vena cava filter placement, vascular embolization, transjugular liver biopsy, adrenal vein sampling, transjugular intrahepatic portosystemic shunt (TIPS) creation, and biliary drainage between June 12, 2014, and April 26, 2018, using integrated dosimetry software. In all, 4,784 procedures were analyzed.

View Article and Find Full Text PDF

Background: Neurointerventional procedures represent a significant source of ionizing radiation. We sought to assess the effect during neurointerventional procedures of varying default rates of radiation dose in fluoroscopy (F) and image acquisition (IA) modes, and frame rates during cine acquisition (CINE) on total X-ray dose, acquisition exposures, fluoroscopy time, and complications.

Methods: We retrospectively reviewed procedures performed with two radiation dose and CINE settings: a factory setting dose cohort (30 patients, F 45 nGy/pulse, IA 3.

View Article and Find Full Text PDF

Objective: Systemic lupus erythematosus patients are frequently evaluated for chest pain and may have multiple pulmonary embolism (PE) computed tomography (CT) scans. This study was undertaken to determine the incidence of pulmonary embolism in the University of Michigan Lupus Cohort patients who have undergone PE CT scans and to estimate the associated increased risk of breast and lung cancer from radiation exposure.

Methods: We reviewed records of patients in the University of Michigan Lupus Cohort (n = 854) and determined the number and outcome of PE CT scans.

View Article and Find Full Text PDF

Background: We compared the effective dose of radiation associated with pedicle screw placement in posterior spinal fusion in children using intraoperative computed tomography (CT) navigation versus intraoperative fluoroscopy (C-arm).

Methods: In this review of posterior spinal fusion patients, height, weight, local density function, dose area product, body region, number of views, and part of the body were used to calculate the effective dose to the patient in millisieverts (mSv) in 37 children in whom pedicle screw placement was aided by intraoperative CT versus 44 children in whom pedicle screw placement was aided by C-arm. Both groups had posterior spinal fusions during the same time period by 3 surgeons between November 2012 and August 2013.

View Article and Find Full Text PDF

Background: There is heterogeneity in how pediatric voiding cystourethrography (VCUG) is performed. Some institutions, including our own, obtain a radiographic scout image prior to contrast agent instillation.

Objective: To demonstrate that the radiographic scout image does not augment VCUG interpretation or contribute management-changing information but nonetheless carries a non-negligible effective dose.

View Article and Find Full Text PDF

The effect of acquisition geometry in digital breast tomosynthesis was evaluated with studies of contrast-to-noise ratios (CNRs) and observer preference. Contrast-detail (CD) test objects in 5 cm thick phantoms with breast-like backgrounds were imaged. Twelve different angular acquisitions (average glandular dose for each ~1.

View Article and Find Full Text PDF

The radiation dose involved in any medical imaging modality that uses ionizing radiation needs to be well understood by the medical physics and clinical community. This is especially true of screening modalities. Digital breast tomosynthesis (DBT) has recently been introduced into the clinic and is being used for screening for breast cancer in the general population.

View Article and Find Full Text PDF

Purpose: To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy.

Methods: The DEQCT method was applied to 80/140 kVp images of patient-simulating lumbar sectional body phantoms of three sizes (small, medium, and large). External calibration rods of bone, red marrow, and fat-simulating materials were placed beneath the body phantoms.

View Article and Find Full Text PDF

Background: Over the last decade there has been escalating concern regarding the increasing radiation exposure stemming from CT exams, particularly in children. Adaptive statistical iterative reconstruction (ASIR) is a relatively new and promising tool to reduce radiation dose while preserving image quality. While encouraging results have been found in adult head and chest and body imaging, validation of this technique in pediatric population is limited.

View Article and Find Full Text PDF

A new approach to the problem of environmental hazard assessment and monitoring for pollutant biodegradation reaction systems in the presence of uncertainty is proposed using soft sensor-based pollutant concentration dynamic profile reconstruction techniques. In particular, a robust reduced-order soft sensor is proposed that can be digitally implemented in the presence of inherent complexity and the inevitable model uncertainty. The proposed method explicitly incorporates all the available information associated with a process model characterized by varying degrees of uncertainty, as well as available sensor measurements of certain physicochemical quantities.

View Article and Find Full Text PDF

Lung cancer screening with low dose computed tomography (CT) is the only method ever proven to reduce lung cancer-specific mortality in high-risk current and former cigarette smokers. Radiation exposure from annual screening CT examinations and subsequent CT and nuclear medicine testing to further evaluate positive screening CTs is sometimes raised as a reason to avoid screening and is often misunderstood. With all testing, there are potential benefits and risks.

View Article and Find Full Text PDF

Purpose: To retrospectively compare image quality and radiation dose between a reduced-dose computed tomographic (CT) protocol that uses model-based iterative reconstruction (MBIR) and a standard-dose CT protocol that uses 30% adaptive statistical iterative reconstruction (ASIR) with filtered back projection.

Materials And Methods: Institutional review board approval was obtained. Clinical CT images of the chest, abdomen, and pelvis obtained with a reduced-dose protocol were identified.

View Article and Find Full Text PDF

Objective: The purpose of this study was to retrospectively evaluate diagnostic imaging trends and radiation exposure in pediatric inflammatory bowel disease (IBD) at a U.S. academic children's hospital between 2001 and 2010.

View Article and Find Full Text PDF

Purpose: This study was performed to investigate the accuracies of the synthesized monochromatic images and effective atomic number maps obtained with the new GE Discovery CT750 HD CT scanner.

Methods: A Gammex-RMI model 467 tissue characterization phantom and the CT number linearity section of a Phantom Laboratory Catphan 600 phantom were scanned using the dual energy (DE) feature on the GE CT750 HD scanner. Synthesized monochromatic images at various energies between 40 and 120 keV and effective atomic number (Z(eff)) maps were generated.

View Article and Find Full Text PDF

Objectives: The objective of the study was to estimate the increased lifetime cancer risk associated with a single computed tomography (CT) examination for calculus detection in pediatric patients and compare it with the lifetime natural cancer risk.

Methods: We used the program CT-Expo to calculate the radiation doses to various abdominal and pelvic organs for age-appropriate pediatric renal stone CT examination protocols used at our institution. Using the Biological Effects of Ionizing Radiation (BEIR) VII report, we estimated the lifelong cancer risk for these organs and compared it with the natural cancer risk for the same organs as predicted by the Surveillance, Epidemiology and End Results data from the National Cancer Institute.

View Article and Find Full Text PDF

Objective: To determine population-based rates of the use of diagnostic imaging procedures with ionizing radiation in children, stratified by age and sex.

Design: Retrospective cohort analysis.

Setting: All settings using imaging procedures with ionizing radiation.

View Article and Find Full Text PDF

Objectives: To compare the usefulness of HRCT of the chest versus spirometric measures (PFTs) in evaluating the effect of tobramycin solution for inhalation (TSI) in cystic fibrosis (CF).

Methods: Thirty-two CF patients with mostly mild lung disease age > or = 6 years, were enrolled in a double-blind, placebo-controlled pilot study. Patients were chronically colonized with Pseudomonas aeruginosa for at least 6 months prior to and at enrollment.

View Article and Find Full Text PDF

Calcium concentration may be a useful feature for distinguishing benign from malignant lung nodules in computer-aided diagnosis. The calcium concentration can be estimated from the measured CT number of the nodule and a CT number vs calcium concentration calibration line that is derived from CT scans of two or more calcium reference standards. To account for CT number nonuniformity in the reconstruction field, such calibration lines may be obtained at multiple locations within lung regions in an anthropomorphic phantom.

View Article and Find Full Text PDF

The new NCRP Report No. 147 includes methodology to determine x-ray protective shielding for CT scanner rooms. This methodology assumes fixed values of the scatter fraction per centimeter (kappa) for the peripheral axis of the head and body CT phantoms.

View Article and Find Full Text PDF

To evaluate the sensitivity of high-resolution computerized tomography (HRCT) of the chest compared to spirometry measures in evaluating the effects of tobramycin solution for inhalation (TSI) in cystic fibrosis (CF) patients.Thirty-two subjects >/=6 years old with mild to moderate CF lung disease were enrolled in a randomized, double-blind, placebo-controlled pilot study. Duration was 28 days; 31 subjects completed the study.

View Article and Find Full Text PDF

A study was performed to determine the accuracies and reproducibilities of the CT numbers of simulated lung nodules imaged with multi-detector CT scanners. The nodules were simulated by spherical balls of three diameters (4.8, 9.

View Article and Find Full Text PDF

A study was conducted to evaluate the radiation transmission through lead equivalent aprons that are used in a radiology department. A large area beam (poor geometry) was employed for the transmission measurements, and backscatter was simulated by placing 7" of Lucite behind each apron. Separate ionization chambers were used to measure the incident and transmitted x-ray beams.

View Article and Find Full Text PDF