Publications by authors named "Emily Vivianne Freitas da Silva"

The objective of this study was to analyze the influence of insertion torque, bone type, and peri-implant bone loss on implant stability quotient (ISQ) of cylindrical external hexagon (EH) and Morse Taper (MT) implants. Forty-four single implants were placed in the edentulous areas of 20 patients who met the inclusion and exclusion criteria. Immediately after implant placement (t1) and after osseointegration (four and six months for mandible and maxilla, respectively) (t2), insertion torque, resonance frequency, and peri-implant bone loss were measured using probing depths and digital periapical radiography.

View Article and Find Full Text PDF

Objective: To evaluate the touch perception threshold of the alveolar mucosa and quality of life of edentulous patients before (T0) and 30 days after (T1) the insertion of new complete dentures.

Background: Touch perception is important so that edentulous patients can detect the position of complete dentures in their mouth.

Materials And Methods: This study included 32 complete denture wearers with good oral and systemic health and no temporomandibular disorders for at least 5 years.

View Article and Find Full Text PDF

In this study, we aimed to evaluate the halitosis and pain threshold of the peri-implant soft tissues in individuals rehabilitated with implant-supported prostheses. Forty-eight subjects were divided into four groups (n = 12) according to their prosthetic rehabilitation: single-tooth fixed prosthesis, multi-tooth fixed prosthesis, overdentures, and the Brånemark protocol. Halitosis was measured using a halimeter, whereas the pain threshold was measured using Von Frey monofilaments.

View Article and Find Full Text PDF

Statement Of Problem: With the growing use of digital scanning, an evaluation of the clinical impact of digital scans versus conventional impressions in complete arch implant-supported prostheses is needed. However, systematic reviews on this subject are lacking.

Purpose: The purpose of this systematic review was to evaluate the scanning and impression times and the radiographic marginal bone loss over time associated with digital scans and conventional impressions for complete arch implant-supported fixed prostheses.

View Article and Find Full Text PDF

Statement Of Problem: Implant-supported fixed dental prostheses can be cement- or screw-retained on the implant or abutment, with advantages and disadvantages for each method. Cemented prostheses have been associated with peri-implant disease because cement remnants act as a reservoir for bacteria and hinder biofilm control. However, contrasting evidence has been presented regarding this association based on studies with varying designs, and a systematic review and meta-analysis is required.

View Article and Find Full Text PDF

Background: Ocular prosthesis rehabilitation has an important social, psychological, esthetic, and functional role. Congenital factors, trauma, and tumors, among others, can cause anophthalmia, and it is essential to identify the etiology to guide its prevention and treatment.

Methods: The aim of this study was to retrospectively investigate the records of patients treated from 2013 to 2020 by the Oral and Maxillofacial Prosthesis Group, aiming to identify the prevalence of patients with anophthalmia and the etiology of their anophthalmia.

View Article and Find Full Text PDF

Background: Polymethylmethacrylate (PMMA) is the most used material for the manufacturing of eye prostheses.

Objectives: To investigate the cytotoxicity of different cleaning agents for ocular prostheses on human conjunctival cells.

Material And Methods: Six groups of specimens were created (saline, soap, 4% chlorhexidine, hydrogen peroxide, 1% triclosan, and citronella oil).

View Article and Find Full Text PDF

Objective: This pilot, prospective interventional study aimed to analyze the influence of supracrestal tissue height when using the one abutment-one time concept at the time of implant placement, on peri-implant hard and soft tissue remodeling in esthetic areas. The definitive crown was placed 7 days later.

Method And Materials: Facial mucosal margin position, mesial and distal papilla levels, and mesial and distal marginal bone loss were assessed after 7 days (placement of the definitive crown), and 1, 2, 3, 6, and 12 months after implant placement.

View Article and Find Full Text PDF

Background: The aim of this study was to verify if there is a relationship between self-reported pain, PPT (pressure pain threshold) of the masseter, temporal and sternocleidomastoid muscles, pain catastrophizing and quality of life in patients with TMD (temporomandibular disorder) of muscular origin.

Material And Methods: Ninety-seven patients with muscular TMD (TMD group) and 97 asymptomatic (control group) were included in the study. The evaluation methods used were: 1) Self-reported pain was assessed using the Visual Analogue Scale (VAS) for questions 7, 8 and 9 of the RDC/TMD Axis I questionnaire; 2) The PPT assessment was performed using a digital algometer on the masseter, temporal, and sternocleidomastoid muscles (both sides); 3) Pain catastrophizing was assessed using the PCS (Pain Catastrophizing Scale); and 4) Oral health-related quality of life was assessed using the OHIP-14 (Oral Healthy Impact Profile-14).

View Article and Find Full Text PDF

Purpose: To assess the reproducibility of four different centric relation (CR) recording techniques, and time spent performing each technique in edentulous individuals.

Materials And Methods: Four techniques were assessed: extraoral gothic arch (EOGA) tracing, intraoral gothic arch (IOGA) tracing, deglutition (D), and frontal manipulation with tongue elevation (FMTE). Twelve subjects participated in the study; four technique records were performed on each volunteer by the same operator.

View Article and Find Full Text PDF

Background: Temporary prosthesis protects the oral tissues, in addition to providing aesthetic look and masticatory function until a definitive prosthesis is manufactured.

Objectives: To evaluate the effect of glaze and 0.12% chlorhexidine (CHX) on the physical and mechanical properties of bis-acryl, and to evaluate the antimicrobial efficacy of CHX.

View Article and Find Full Text PDF

Irritation and biofilm adhesion are complaints associated with ocular prosthesis use. This study aimed to evaluate the effects of prosthesis repolishing on several conditions of anophthalmic volunteers. Participants were divided into two groups: intervention (IG, n = 10) and nonintervention (NIG, n = 6) groups.

View Article and Find Full Text PDF

Objective: This study reports a clinical case of rehabilitation of a patient who had her left little finger amputated at the mesial phalanx because of a gunshot wound. The finger prosthesis was custom- made using a silicone.

Case Description: This study presents a clinical case of a female patient who had her left little finger amputated at the mesial phalanx because of a gunshot wound in 2016.

View Article and Find Full Text PDF

Objective:  This study aimed to evaluate the influence of new complete dentures (CDs) and new removable partial dentures (RPDs) on oral health-related quality of life, dry mouth sensation, and anxiety level of their wearers.

Materials And Methods:  In total, 20 complete edentulous patients (in both arches) that needed to be rehabilitated with new CDs, and 20 partial edentulous patients (in both arches) that needed to be rehabilitated with new RPDs, were included in this study. Each patient must wear the same pair of CDs or RPDs for more than 5 years.

View Article and Find Full Text PDF

Objectives:  The aim of this study was to verify during facial expressions ("happy," "sad," "fearful," "angry," "surprised," and "disgusted") if: (1) there would be difference in the electromyography (EMG) of the occipitofrontalis, temporal, masseter, and sternocleidomastoid muscles on the normal side (NS) compared with the affected side (AS) (without the use of an ocular prosthesis) in individuals with unilateral absence of the eyeball, and (2) the rehabilitation with a new ocular prosthesis would affect the EMG of the muscles studied on the AS in these individuals.

Materials And Methods:  Thirteen individuals, without temporomandibular disorder, with good health, with unilateral absence of the eyeball (the eye must have been removed by evisceration or enucleation), and users or nonusers of an ocular prosthesis were included. EMG of the occipitofrontalis, temporal, masseter, and sternocleidomastoid muscles was performed during rest and facial expressions ("happy," "sad," "fearful," "angry," "surprised," and "disgusted") before (T0) and 90 days after (T1) rehabilitation with a new ocular prosthesis.

View Article and Find Full Text PDF

Background: This study aimed to compare the masticatory efficiency, the maximum voluntary occlusal bite force (MVOBF) and the electrical activity (EMG) of masticatory muscles of practitioners of upper limb bodybuilding before and after physical activity.

Material And Methods: Twenty healthy individuals (10 men and 10 women, age from 18 to 30 (mean of 24.7 years old) without masticatory system disorders, that regularly practice hypertrophic physical activity were submitted to the analyses of masticatory efficiency, MVOBF, and surface EMG of the temporalis and masseter muscles.

View Article and Find Full Text PDF

The study evaluated the influence of cycles and methods of an ocular prosthesis resin on cytotoxicity toward human conjunctival cells. Resins were polymerized by water bath (WB, 74 °C or 100 °C for 30 min to 9 h), microwave (MW, 1200 W, 3 to 14 min and 30 s at 0 to 720 W), or autopolymerization (AP, room temperature for 20 min ± 60 °C for 30 min). Degree of conversion (DC), cytotoxicity, level of inflammatory mediators, gene expression of different markers, and apoptosis were evaluated.

View Article and Find Full Text PDF

Objectives: This study aimed to assess the relation between the insertion torque and implant stability quotient (ISQ recorded immediately and 6 months after implant placement).

Materials And Methods: Twenty-five patients over the age of 18 years were selected for this study. One implant was placed per patient after tooth extraction.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the dimensional stability and maintenance of details of conventional and high stability alginates up to 5-day storage.

Methods: Two types of alginates were selected (n=10) for this study, conventional (Hydrogum) and high stability alginates (Hydrogum 5), which were produced with the aid of a cylindrical metal block and a ring-shaped metal mold (Specifications 18, 19, and 25, ANSI/ADA). Ten images were obtained from the molds for the dimensional stability test, which were taken immediately after their production and at each different storage periods (15 min, 24 h, 48 h, 72 h, 96 h, and 120 h) by a digital camera.

View Article and Find Full Text PDF

Statement Of Problem: The use of 0.12% chlorhexidine gluconate (CHX) may damage bisacrylate composite resin interim restorations, but whether they can be protected with an application of alcohol and/or the use of a glaze is unclear.

Purpose: The purpose of this in vitro study was to evaluate the effect of applying a 70% alcohol solution on the physical and mechanical properties of a bisacrylate composite resin, with and without the application of a light-polymerizing glaze subjected to 0.

View Article and Find Full Text PDF

The objective of this study was to compare techniques of different methods of obtaining centric relation to verify which technique generates the greatest reproducibility of the centric relation. The PubMed/MEDLINE, Cochrane Library, SciELO, Scopus, and Web of Science databases were searched for articles published up to May 15, 2018. The search terms were combinations of "dental centric relation" with each of the following terms (individually): "reproducibility of findings"; "jaw relation record"; "chin point"; "gothic arch"; "bimanual manipulation"; "swallowing"; and "jig.

View Article and Find Full Text PDF

Statement Of Problem: Exposure of silicone prostheses to environmental factors can alter their properties, affecting longevity. However, whether nonthermal plasma (NTP) can prevent these alterations is unclear.

Purpose: The purpose of this in vitro study was to evaluate the surface roughness (Ra), sorption, solubility, and color stability (ΔE) of the MDX4-4210 and A-120 silicones, with and without NTP treatment in accordance with an independent analysis of the use of 2 pigmentations.

View Article and Find Full Text PDF

Objective: Temporomandibular dysfunction (TMD), anxiety, and depression are disorders that, due to the current lifestyle, are affecting an increasing portion of the population. Investigating the prevalence of the symptoms of these disorders during the quarantine due to the coronavirus 2019 pandemic (COVID-19) is important to outline clinical strategies for patient care. This study assessed the prevalence of TMD symptoms, anxiety, depression, and oral behaviors and their associations during the social isolation due to COVID-19.

View Article and Find Full Text PDF

Statement Of Problem: Biofilms can be retained on dental prostheses leading to the development of infections. The indiscriminate use of antifungal drugs can result in the development of microorganisms that are resistant to these antimicrobial agents. Whether probiotics are a suitable alternative for reducing the prevalence of oral candidiasis is unclear.

View Article and Find Full Text PDF

Purpose: To evaluate the roughness, surface energy, and the bond strength of lithium disilicate yielded by two different types of nonthermal plasma (NTP), oxygen- or argon-based, compared to the conventional method.

Materials And Methods: Ninety-three lithium disilicate (IPS e.max Press) samples were divided into 3 groups: HF (hydrofluoric acid group); ONTP (oxygen-based NTP group); ANTP (argon-based NTP group).

View Article and Find Full Text PDF