Publications by authors named "Emily Vivianne Freitas Silva"

Objective: To evaluate the touch perception threshold of the alveolar mucosa and quality of life of edentulous patients before (T0) and 30 days after (T1) the insertion of new complete dentures.

Background: Touch perception is important so that edentulous patients can detect the position of complete dentures in their mouth.

Materials And Methods: This study included 32 complete denture wearers with good oral and systemic health and no temporomandibular disorders for at least 5 years.

View Article and Find Full Text PDF

Statement Of Problem: With the growing use of digital scanning, an evaluation of the clinical impact of digital scans versus conventional impressions in complete arch implant-supported prostheses is needed. However, systematic reviews on this subject are lacking.

Purpose: The purpose of this systematic review was to evaluate the scanning and impression times and the radiographic marginal bone loss over time associated with digital scans and conventional impressions for complete arch implant-supported fixed prostheses.

View Article and Find Full Text PDF

Statement Of Problem: Implant-supported fixed dental prostheses can be cement- or screw-retained on the implant or abutment, with advantages and disadvantages for each method. Cemented prostheses have been associated with peri-implant disease because cement remnants act as a reservoir for bacteria and hinder biofilm control. However, contrasting evidence has been presented regarding this association based on studies with varying designs, and a systematic review and meta-analysis is required.

View Article and Find Full Text PDF

Objective: This pilot, prospective interventional study aimed to analyze the influence of supracrestal tissue height when using the one abutment-one time concept at the time of implant placement, on peri-implant hard and soft tissue remodeling in esthetic areas. The definitive crown was placed 7 days later.

Method And Materials: Facial mucosal margin position, mesial and distal papilla levels, and mesial and distal marginal bone loss were assessed after 7 days (placement of the definitive crown), and 1, 2, 3, 6, and 12 months after implant placement.

View Article and Find Full Text PDF

Background: The aim of this study was to verify if there is a relationship between self-reported pain, PPT (pressure pain threshold) of the masseter, temporal and sternocleidomastoid muscles, pain catastrophizing and quality of life in patients with TMD (temporomandibular disorder) of muscular origin.

Material And Methods: Ninety-seven patients with muscular TMD (TMD group) and 97 asymptomatic (control group) were included in the study. The evaluation methods used were: 1) Self-reported pain was assessed using the Visual Analogue Scale (VAS) for questions 7, 8 and 9 of the RDC/TMD Axis I questionnaire; 2) The PPT assessment was performed using a digital algometer on the masseter, temporal, and sternocleidomastoid muscles (both sides); 3) Pain catastrophizing was assessed using the PCS (Pain Catastrophizing Scale); and 4) Oral health-related quality of life was assessed using the OHIP-14 (Oral Healthy Impact Profile-14).

View Article and Find Full Text PDF

Purpose: To assess the reproducibility of four different centric relation (CR) recording techniques, and time spent performing each technique in edentulous individuals.

Materials And Methods: Four techniques were assessed: extraoral gothic arch (EOGA) tracing, intraoral gothic arch (IOGA) tracing, deglutition (D), and frontal manipulation with tongue elevation (FMTE). Twelve subjects participated in the study; four technique records were performed on each volunteer by the same operator.

View Article and Find Full Text PDF

Irritation and biofilm adhesion are complaints associated with ocular prosthesis use. This study aimed to evaluate the effects of prosthesis repolishing on several conditions of anophthalmic volunteers. Participants were divided into two groups: intervention (IG, n = 10) and nonintervention (NIG, n = 6) groups.

View Article and Find Full Text PDF

Objective: This study reports a clinical case of rehabilitation of a patient who had her left little finger amputated at the mesial phalanx because of a gunshot wound. The finger prosthesis was custom- made using a silicone.

Case Description: This study presents a clinical case of a female patient who had her left little finger amputated at the mesial phalanx because of a gunshot wound in 2016.

View Article and Find Full Text PDF

Objective:  This study aimed to evaluate the influence of new complete dentures (CDs) and new removable partial dentures (RPDs) on oral health-related quality of life, dry mouth sensation, and anxiety level of their wearers.

Materials And Methods:  In total, 20 complete edentulous patients (in both arches) that needed to be rehabilitated with new CDs, and 20 partial edentulous patients (in both arches) that needed to be rehabilitated with new RPDs, were included in this study. Each patient must wear the same pair of CDs or RPDs for more than 5 years.

View Article and Find Full Text PDF

Objectives:  The aim of this study was to verify during facial expressions ("happy," "sad," "fearful," "angry," "surprised," and "disgusted") if: (1) there would be difference in the electromyography (EMG) of the occipitofrontalis, temporal, masseter, and sternocleidomastoid muscles on the normal side (NS) compared with the affected side (AS) (without the use of an ocular prosthesis) in individuals with unilateral absence of the eyeball, and (2) the rehabilitation with a new ocular prosthesis would affect the EMG of the muscles studied on the AS in these individuals.

Materials And Methods:  Thirteen individuals, without temporomandibular disorder, with good health, with unilateral absence of the eyeball (the eye must have been removed by evisceration or enucleation), and users or nonusers of an ocular prosthesis were included. EMG of the occipitofrontalis, temporal, masseter, and sternocleidomastoid muscles was performed during rest and facial expressions ("happy," "sad," "fearful," "angry," "surprised," and "disgusted") before (T0) and 90 days after (T1) rehabilitation with a new ocular prosthesis.

View Article and Find Full Text PDF

Background: This study aimed to compare the masticatory efficiency, the maximum voluntary occlusal bite force (MVOBF) and the electrical activity (EMG) of masticatory muscles of practitioners of upper limb bodybuilding before and after physical activity.

Material And Methods: Twenty healthy individuals (10 men and 10 women, age from 18 to 30 (mean of 24.7 years old) without masticatory system disorders, that regularly practice hypertrophic physical activity were submitted to the analyses of masticatory efficiency, MVOBF, and surface EMG of the temporalis and masseter muscles.

View Article and Find Full Text PDF

The study evaluated the influence of cycles and methods of an ocular prosthesis resin on cytotoxicity toward human conjunctival cells. Resins were polymerized by water bath (WB, 74 °C or 100 °C for 30 min to 9 h), microwave (MW, 1200 W, 3 to 14 min and 30 s at 0 to 720 W), or autopolymerization (AP, room temperature for 20 min ± 60 °C for 30 min). Degree of conversion (DC), cytotoxicity, level of inflammatory mediators, gene expression of different markers, and apoptosis were evaluated.

View Article and Find Full Text PDF

The aim of this study was to compare the use of titanium and ceramic implants for overdentures in terms of their failure rates, surface treatments, and marginal bone loss (MBL). The literature was searched using the PubMed, Scopus, and Cochrane databases up to October 2019. Clinical studies in which ceramic and titanium implants for overdentures were compared in terms of their failure rates, surface treatments, and MBL were included in the meta-analysis.

View Article and Find Full Text PDF

Statement Of Problem: The use of 0.12% chlorhexidine gluconate (CHX) may damage bisacrylate composite resin interim restorations, but whether they can be protected with an application of alcohol and/or the use of a glaze is unclear.

Purpose: The purpose of this in vitro study was to evaluate the effect of applying a 70% alcohol solution on the physical and mechanical properties of a bisacrylate composite resin, with and without the application of a light-polymerizing glaze subjected to 0.

View Article and Find Full Text PDF

The objective of this study was to compare techniques of different methods of obtaining centric relation to verify which technique generates the greatest reproducibility of the centric relation. The PubMed/MEDLINE, Cochrane Library, SciELO, Scopus, and Web of Science databases were searched for articles published up to May 15, 2018. The search terms were combinations of "dental centric relation" with each of the following terms (individually): "reproducibility of findings"; "jaw relation record"; "chin point"; "gothic arch"; "bimanual manipulation"; "swallowing"; and "jig.

View Article and Find Full Text PDF

Purpose: To evaluate the roughness, surface energy, and the bond strength of lithium disilicate yielded by two different types of nonthermal plasma (NTP), oxygen- or argon-based, compared to the conventional method.

Materials And Methods: Ninety-three lithium disilicate (IPS e.max Press) samples were divided into 3 groups: HF (hydrofluoric acid group); ONTP (oxygen-based NTP group); ANTP (argon-based NTP group).

View Article and Find Full Text PDF

Objective: Overcoming substantial shortcomings of soft liners as physico-chemical changes and liner-biofilm-related infections remains a challenge in the rehabilitation treatment. In this study, protective non-thermal plasma (NTP) treatments were developed on the soft liner surface to improve its surface and physico-chemical properties and to reduce fungal colonization after biofilm inhibition challenge.

Methods: Resinous liner specimens (Coe-Soft) were prepared and distributed in 3 groups according to the surface treatments: (1) untreated (control); (2) treated with sulfur hexafluoride-based NTP (SF); and (3) treated with hexamethyldisiloxane-based NTP (HMDSO).

View Article and Find Full Text PDF

Purpose: The aim was to evaluate the effect of four acidic beverages on the roughness (Ra) and color change (ΔE) of two brands of artificial teeth and a heat-polymerized acrylic resin (HPAR) for use in a prosthetic base.

Materials And Methods: All materials were divided into 5 groups, according to the used acidic beverage (artificial saliva - control, red wine, orange juice, coke-based, and lemon juice-based soft drink). The immersion process was divided into two stages: T1 - immersion in the acidic solutions for 10 minutes for 14 days; T2 - after T1, the samples were immersed in grape juice for 14 days.

View Article and Find Full Text PDF

Background: Different ceramic surface cleaning methods have been suggested after the acid conditioning. The aim was to evaluate the effect of different protocols used to remove the remaining hydrofluoric acid on the shear bond strength (SBS) between lithium disilicate and resin cement.

Material And Methods: Forty-four specimens of lithium disilicate (IPS e.

View Article and Find Full Text PDF

Background: The aim of this study was to verify, through self-assessment questionnaires, the influence of implant-supported prosthesis in salivary flow and anxiety of patients rehabilitated with them.

Materials And Methods: Visual analog scale (VAS) questionnaire about xerostomia and State-Trait Anxiety Inventory were applied before (T1) and after 2 days (T2) and 3 weeks (T3) of prostheses installation. The study included patients rehabilitated with implant-supported prostheses containing three or more dental elements.

View Article and Find Full Text PDF

Background: The aim of this study was to evaluate the distribution of stress in complete fixed mandibular prostheses with infrastructures (IE) fabricated with different materials and techniques, under compressive force.

Material And Methods: A model of an edentulous mandible, which received five 4x11 mm external hexagon implants between the mental foramens, was fabricated. The groups were divided into: Group I - IE in nickel-chromium with an acrylic resin occlusal coating; Group II - IE in nickel-chromium with a ceramic occlusal coating; Group III - IE milled in zirconia with a ceramic coating.

View Article and Find Full Text PDF

Aim: This study aimed to investigate the adhesion of Streptococcus sanguinis to the surface of interim prostheses that were treated or not treated with a light-activated glaze, and subjected or not subjected to a thermocycling procedure.

Methods: 36 specimens of each resin were divided into 4 groups: heat-activated acrylic resin; chemically-activated acrylic resin; bis-acryl composite resin (Protemp; 3M ESPE); and bis-GMA (Charisma; Heraeus Kulzer). Half of the specimens underwent application of glaze and the other half underwent mechanical polishing.

View Article and Find Full Text PDF

Purpose: To investigate the influence of nonthermal plasma (NTP) treatment on the tensile bond strength between heat-polymerized acrylic resin for ocular prostheses and silicone reliner, with and without the use of an adhesive primer.

Materials And Methods: One-hundred and sixty-four acrylic resin specimens were fabricated and randomly distributed into four groups according to the type of surface treatment: Sofreliner Primer, NTP, Sofreliner Primer + NTP, and NTP + Sofreliner Primer. Two specimens interposed with relining material (Sofreliner) formed one test sample to perform the tensile bond strength tests, before (initial) and after storage (final) in saline solution (37°C, 90 days, n = 10).

View Article and Find Full Text PDF

Background: The aim was to analyze the levels of stress of edentulous patients through the state-trait anxiety inventory (STAI) and salivary flow through the visual analogue scale (VAS) xerostomia questionnaire, as well as analyze the levels of cortisol, capillary blood glucose, and blood pressure (BP) before and after the installation of complete dentures.

Methods: Fifty patients were evaluated. The STAI and VAS xerostomia questionnaire were applied before the installation of the prosthesis, on the day of its installation, and 1 month after the last recall visit.

View Article and Find Full Text PDF

In some clinical situations, the clinician may encounter previously installed implants that should be associated with other implants for a proper rehabilitation. The aim of this study was to evaluate the biomechanical behaviour of a multiple prosthesis joined by different implant connections using photoelasticity. Photoelastic models with a screwed fixed prosthesis supported by implants with different connection systems (Morse taper, external hexagon, internal hexagon, and Flexcone), and different combinations among them, were fabricated.

View Article and Find Full Text PDF