Brown adipose tissue undergoes a dynamic, heterogeneous response to cold exposure that can include the simultaneous synthesis, uptake, and oxidation of fatty acids. The purpose of this work was to quantify these changes in brown adipose tissue lipid content (fat-signal fraction (FSF)) using fat-water magnetic resonance imaging during individualized cooling to 3 °C above a participant's shiver threshold. Eight healthy men completed familiarization, perception-based cooling, and MRI-cooling visits.
View Article and Find Full Text PDFAs new techniques are developed to image adipose tissue, methods to validate such protocols are becoming increasingly important. Phantoms, experimental replicas of a tissue or organ of interest, provide a low cost, flexible solution. However, without access to expensive and specialized equipment, constructing stable phantoms with high fat fractions (e.
View Article and Find Full Text PDFCold exposure, a known stimulant of the thermogenic effects of brown adipose tissue (BAT), is the most widely used method to study BAT physiology in adult humans. Recently, individualized cooling has been recommended to standardize the physiological cold stress applied across participants, but critical experimental details remain unclear. The purpose of this work was to develop a detailed methodology for an individualized, perception-based protocol to investigate human physiological responses to cooling.
View Article and Find Full Text PDFMuscle blood oxygenation-level dependent (BOLD) contrast is greater in magnitude and potentially more influenced by extravascular BOLD mechanisms at 7 T than it is at lower field strengths. Muscle BOLD imaging of muscle contractions at 7 T could, therefore, provide greater or different contrast than at 3 T. The purpose of this study was to evaluate the feasibility of using BOLD imaging at 7 T to assess the physiological responses to in vivo muscle contractions.
View Article and Find Full Text PDFAutomated software improves the accuracy and reliability of blood velocity, vessel diameter, blood flow, and shear rate ultrasound measurements, but existing software offers limited flexibility to customize and validate analyses. We developed FloWave.US-open-source software to automate ultrasound blood flow analysis-and demonstrated the validity of its blood velocity (aggregate relative error, 4.
View Article and Find Full Text PDFThe mechanical functions of muscles involve the generation of force and the actuation of movement by shortening or lengthening under load. These functions are influenced, in part, by the internal arrangement of muscle fibers with respect to the muscle's mechanical line of action. This property is known as muscle architecture.
View Article and Find Full Text PDFHand hygiene compliance is the most significant, modifiable cause of hospital-acquired infections, yet national averages for compliance rates remain unsatisfactory. Noncompliance can contribute to patient mortality, extended hospital stays, higher re-admission rates, and lower reimbursement for hospitals under the Patient Protection and Affordable Care Act. Although several hand sanitizing tracking systems currently exist, they pose problems of personal tracking, workflow interference, system maintenance concerns, among others.
View Article and Find Full Text PDFPurpose: The purpose of this study was to determine the feasibility of muscle BOLD (mBOLD) imaging at 7 Tesla (T) by comparing the changes in R2* of muscle at 3 and 7T in response to a brief period of tourniquet-induced ischemia.
Methods: Eight subjects (three male), aged 29.5 ± 6.