Publications by authors named "Emile van der Heide"

Successful osseointegration of press-fit implants depends on the initial stability, often measured by the micromotions between the implant and bone. A good primary stability can be achieved by optimizing the compressive and frictional forces acting at the bone-implant interface. The frictional properties of the implant-bone interface, which depend on the roughness and porosity of the implant surface coating, can affect the primary stability.

View Article and Find Full Text PDF

Hip joint prostheses are used to replace hip joint function in the human body. The latest dual-mobility hip joint prosthesis has an additional component of an outer liner that acts as a cover for the liner component. Research on the contact pressure generated on the latest model of a dual-mobility hip joint prosthesis under a gait cycle has never been done before.

View Article and Find Full Text PDF

Bearing on artificial hip joint experiences friction, wear, and surface damage that impact on overall performance and leading to failure at a particular time due to continuous contact that endangers the user. Assessing bearing hip joint using clinical study, experimental testing, and mathematical formula approach is challenging because there are some obstacles from each approach. Computational simulation is an effective alternative approach that is affordable, relatively fast, and more accessible than other approaches in examining various complex conditions requiring extensive resources and several different parameters.

View Article and Find Full Text PDF

Due to various concerns about the use of metal-on-metal that is detrimental to users, the use of metal as acetabular cup material was later changed to ultra high molecular weight polyethylene (UHMWPE). However, the wear on UHMWPE releases polyethylene wear particles, which can trigger a negative body response and contribute to osteolysis. For reducing the wear of polyethylene, one of the efforts is to investigate the selection of metal materials.

View Article and Find Full Text PDF

Cementless total knee arthroplasty (TKA) components have rough and porous surface coatings which can enhance bone ingrowth and stability at the bone-implant. To achieve primary stability in the postoperative period where no apposition is formed, the resistance against motions between bone and implant is optimized by increasing the friction at the interface. This is necessary, as excessive relative motions can inhibit bone ingrowth, which might result in loosening and pain.

View Article and Find Full Text PDF

The selection of biomaterials for bearing in total hip arthroplasty is very important to avoid various risks of primary postoperative failure for patients. The current investigation attempts to analyze the Tresca stress of metal-on-metal bearings with three different materials, namely, cobalt chromium molybdenum (CoCrMo), stainless steel 316L (SS 316L), and titanium alloy (Ti6Al4V). We used computational simulations using a 2D axisymmetric finite element model to predict Tresca stresses under physiological conditions of the human hip joint during normal walking.

View Article and Find Full Text PDF

Wear and wear-induced debris is a significant factor in causing failure in implants. Reducing contact pressure by using a textured surface between the femoral head and acetabular cup is crucial to improving the implant's life. This study presented the effect of surface texturing as dimples on the wear evolution of total hip arthroplasty.

View Article and Find Full Text PDF

Failure of the cement mantle in total hip arthroplasty is not a simple phenomenon. Cracking, which can be caused by crack initiation and repeated loading, can cause loosening of the acetabular liner component. A previous study showed that addition of a metal layer between the liner and acetabular could reduce the stress at the contact surface of the cement mantle.

View Article and Find Full Text PDF

Introduction: Ultrahigh-molecular-weight polyethylene (UHMWPE) is a thermoplastic polymer useful in biomaterial applications, especially in orthopedic field. Yet, little is known concerning its initial effect on human bone marrow stem cells (hBMSCs) after implantation.

Materials And Methods: A cytotoxicity analysis was performed with a 3-(4,5-dimethylthiazol 2-yl)-2,5-diphenyltetrazolium assay after 24, 48, and 72h of incubation of hBMSC culture.

View Article and Find Full Text PDF

The frictional performances of surgical sutures have been found to play a vital role in their functionality. The purpose of this paper is to understand the frictional performance of multifilament surgical sutures interacting with skin substitute, by means of a penetration friction apparatus (PFA). The influence of the size of the surgical suture was investigated.

View Article and Find Full Text PDF

Surgical sutures have different sizes, structures, whereas they are being used for various surgeries. The high friction performance of surgical sutures in the suturing process may cause inflammation and pain, leading to a longer recovery time. This paper presents an understanding of the tribological behavior of surgical suture with monofilament and multifilament structures, by means of a penetration friction apparatus (PFA).

View Article and Find Full Text PDF

Human bone marrow-derived mesenchymal cell (hBMC) reactions to 316L stainless steel (316L-SS) have never been evaluated. The objective of this study was to assess cell viability and interleukin-6 expression of hBMC cultures upon treatment with a 316L-SS implant. A cytotoxicity analysis was conducted with a 3-(4,5-dimethylthiazol 2-yl)-2,5-diphenyltetrazolium (MTT) assay after a period of 24, 48 and 72 hours of incubation.

View Article and Find Full Text PDF

Nowadays there is a wide variety of surgical sutures available in the market. Surgical sutures have different sizes, structures, materials and coatings, whereas they are being used for various surgeries. The frictional performances of surgical sutures have been found to play a vital role in their functionality.

View Article and Find Full Text PDF

Background: Impingement of an artificial hip joint because of limited range of motion (RoM) during human activity is one of the main sources of hip joint failure. The aim of this article is to simulate the RoMs of hip joints during salat, the practice of formal worship in Islam.

Methods: Salat consists of several stages which can be represented with a cycle (raka'ah).

View Article and Find Full Text PDF

Additive manufactured scaffolds are fabricated from three commonly used biomaterials, polycaprolactone (PCL), poly (L\DL) lactic acid (P(L\DL)LA), and poly(ethylene oxide terephthalate)/poly(butylene terephthalate) (PEOT/PBT). Scaffolds are compared biologically and tribologically. Cell-seeded PEOT/PBT scaffolds cultured in osteogenic and chondrogenic differentiation media show statistical significantly higher alkaline phosphatase (ALP) activity/DNA and glycosaminoglycans (GAG)/DNA ratios, followed by PCL and P(L\DL)LA scaffolds, respectively.

View Article and Find Full Text PDF