Background And Aims: The optimal antithrombotic therapy in patients with device-detected atrial fibrillation (DDAF) is unknown. Concomitant vascular disease can modify the benefits and risks of anticoagulation.
Methods: These pre-specified analyses of the NOAH-AFNET 6 (n = 2534 patients) and ARTESiA (n = 4012 patients) trials compared anticoagulation with no anticoagulation in patients with DDAF with or without vascular disease, defined as prior stroke/transient ischaemic attack, coronary or peripheral artery disease.
Background: Short and rare episodes of atrial fibrillation (AF) are commonly detected using implanted devices (device-detected AF) in patients with prior stroke or transient ischemic attack (TIA). The effectiveness and safety of oral anticoagulation in patients with prior stroke or TIA and device-detected AF but with no ECG-documented AF is unclear.
Methods And Results: This prespecified analysis of the NOAH-AFNET 6 (Non-Vitamin K Antagonist Oral Anticoagulants in Patients With Atrial High Rate Episodes) trial with post hoc elements assessed the effect of oral anticoagulation in patients with device-detected AF with and without a prior stroke or TIA in the randomized, double-blind, double-dummy NOAH-AFNET 6 trial.
J Cardiovasc Electrophysiol
March 2024
Background And Aims: Patients with long atrial high-rate episodes (AHREs) ≥24 h and stroke risk factors are often treated with anticoagulation for stroke prevention. Anticoagulation has never been compared with no anticoagulation in these patients.
Methods: This secondary pre-specified analysis of the Non-vitamin K antagonist Oral anticoagulants in patients with Atrial High-rate episodes (NOAH-AFNET 6) trial examined interactions between AHRE duration at baseline and anticoagulation with edoxaban compared with placebo in patients with AHRE and stroke risk factors.
Background: Device-detected atrial high-rate episodes (AHREs) are atrial arrhythmias detected by implanted cardiac devices. AHREs resemble atrial fibrillation but are rare and brief. Whether the occurrence of AHREs in patients without atrial fibrillation (as documented on a conventional electrocardiogram [ECG]) justifies the initiation of anticoagulants is not known.
View Article and Find Full Text PDFPost-acute COVID-19 is characterized by the persistence of dyspnea, but the pathophysiology is unclear. We evaluated the prevalence of dyspnea during follow-up and factors at admission and follow-up associated with dyspnea persistence. After five months from discharge, 225 consecutive patients hospitalized for moderate to severe COVID-19 pneumonia were assessed clinically and by laboratory tests, echocardiography, six-minute walking test (6MWT), and pulmonary function tests.
View Article and Find Full Text PDFAtrial high-rate episodes (AHRE) are atrial tachyarrhythmias detected by continuous rhythm monitoring by pacemakers, defibrillators, or implantable cardiac monitors. Atrial high-rate episodes occur in 10-30% of elderly patients without atrial fibrillation. However, it remains unclear whether the presence of these arrhythmias has therapeutic consequences.
View Article and Find Full Text PDF(1) Background: Emerging data regarding patients recovered from COVID-19 are reported in the literature, but cardiac sequelae have not yet been clarified. To quickly detect any cardiac involvement at follow-up, the aims of the research were to identify: elements at admission predisposing subclinical myocardial injury at follow up; the relationship between subclinical myocardial injury and multiparametric evaluation at follow-up; and subclinical myocardial injury longitudinal evolution. (2) Methods and Results: A total of 229 consecutive patients hospitalised for moderate to severe COVID-19 pneumonia were initially enrolled, of which 225 were available for follow-up.
View Article and Find Full Text PDFBackground: Outcomes of transvenous lead extraction (TLE) are well reported in the general population, However, data on safety, efficacy of TLE in octogenarians with a long lead dwell time, using powered extraction tools are limited. The aim of this multicenter study was to evaluate the safety, effectiveness of TLE in octogenarians using the bidirectional rotational mechanical sheaths and mid-term outcome after TLE.
Methods: The study population comprised 83 patients (78.
Purpose: The aim of the present study was to evaluate the outcome of patients underwent subcutaneous implantable cardioverter defibrillator (S-ICD) implantation with the intermuscular (IM) two-incision technique during 3-year follow-up.
Methods: the study population consisted of 105 consecutive patients (79 male; median 50 [13-77] years) underwent S-ICD implantation with the IM two-incision technique. The composite primary end point of the study consisted of device-related complications and inappropriate shocks (IAS).
Background: Atrial fibrillation (AF) is an uncommon arrhythmia in young adults without structural heart disease, and cryoballoon pulmonary vein isolation (CB-PVI) is an important therapeutic strategy for rhythm control in patients with drug-refractory AF. The aim of this analysis was to evaluate efficacy and safety of CB-PVI in a large cohort of young patients in comparison with middle-aged adults in a real-world setting.
Methods: From 2012 to 2020, a total of 3033 patients with AF underwent CB-PVI and were followed prospectively in the framework of the 1STOP Clinical Service project, involving 34 Italian centers.
Background: Subclinical atrial fibrillation (SCAF) may represent a cause of embolic stroke of undetermined source (ESUS) and its detection has important implications for secondary prevention with anticoagulation. Indications to implantable cardiac monitors (ICM) include SCAF detection. The aims of this study were to (1) evaluate the frequency of ICM-detected SCAF; (2) determine predictors of SCAF; and (3) identify patients who would benefit most from ICM implantation.
View Article and Find Full Text PDFWhen approaching infected lead removal in cardiac device-related infective endocarditis (CDRIE), a surgical consideration for large (>20 mm) vegetations is recommended. We report our experience with the removal of large CDRIE vegetations using the AngioVac system, as an alternative to conventional surgery. We retrospectively reviewed all infected lead extractions performed with a prior debulking using the AngioVac system, between October 2016 and April 2022 at our institution.
View Article and Find Full Text PDFIntroduction: Predictors of late life-threatening arrhythmic events in Brugada syndrome (BrS) patients who received a prophylactic ICD implantation remain to be evaluated. The aim of the present long-term multicenter study was to assess the incidence and clinical-electrocardiographic predictors of late life-threatening arrhythmic events in BrS patients with a prophylactic implantable cardioverter defibrillator (ICD) and undergoing generator replacement (GR).
Methods: The study population included 105 patients (75% males; mean age 45 ± 14years) who received a prophylactic ICD and had no arrhythmic event up to first GR.
Background: The 2020 severe acute respiratory syndrome coronavirus 2 outbreak entailed reduced availability of traditional (in-office) cardiology consultations. Remote monitoring is an alternative way of caring that may potentially mitigate the negative effects of the epidemic to the care of cardiovascular diseases. We evaluated the outcome of implantable cardioverter defibrillator (ICD) carriers followed up remotely in 2020 (epidemic period) versus 2019 (control).
View Article and Find Full Text PDFBackground: Subcutaneous implantable cardioverter defibrillator (S-ICD) is a suitable alternative for transvenous ICD (TV-ICD) patients who have undergone transvenous lead extraction (TLE). Limited data are available on the outcome of S-ICD patients implanted after TLE. We assessed the safety, efficacy, and outcome of S-ICD implantation after TLE of TV-ICD.
View Article and Find Full Text PDFFrom 2020, many countries have adopted several restrictions to limit the COVID-19 pandemic. The forced containment impacted on healthcare organizations and the everyday life of patients with heart disease. We prospectively analyzed data recorded from implantable defibrillators and/or cardiac resynchronization devices of Italian patients during the lockdown (LDP), post-lockdown period (PLDP) and a control period (CP) of the previous year.
View Article and Find Full Text PDFBackground: Recent studies have shown that Evolution RL bidirectional rotational mechanical sheath (Cook Medical, USA) is an effective and safe technique for transvenous lead extraction (TLE). We reported our experience with the bidirectional rotational mechanical tools using a multidisciplinary approach highlighting the value of a joint cardiac surgeon and electrophysiologist collaboration.
Methods: The study population comprised 84 patients (77% male; mean age 65 ± 18 years) undergoing TLE.
When an implantable-cardioverter defibrillator (ICD) lead becomes non-functional, a recommendation currently exists for either lead abandonment or removal. Lead abandonment and subcutaneous ICD (S-ICD) implantation may represent an additional option for patients who do not require pacing. The aim of this study was to investigate the outcomes of a strategy of lead abandonment and S-ICD implantation in the setting of lead malfunction.
View Article and Find Full Text PDF