Publications by authors named "Elwood Armour"

Purpose: As a core component of a new gynecologic cancer radiation program, we envisioned, structured, and implemented a novel Interventional Radiation Oncology (IRO) unit and magnetic resonance (MR)-brachytherapy environment in an existing MR simulator.

Methods And Materials: We describe the external and internal processes required over a 6-8 month time frame to develop a clinical and research program for gynecologic brachytherapy and to successfully convert an MR simulator into an IRO unit.

Results: Support of the institution and department resulted in conversion of an MR simulator to a procedural suite.

View Article and Find Full Text PDF

Background: Intraoperative radiotherapy (IORT) has advantages over external beam radiation therapy (EBRT). Few studies have described side effects associated with its addition. We evaluated our institution's experience with abdominopelvic IORT to assess safety by postoperative complication rates.

View Article and Find Full Text PDF

The accurate measurement of the linear accelerator (linac) radiation isocenter is critical, especially for stereotactic treatment. Traditional quality assurance (QA) procedure focuses on the measurement of single radiation isocenter, usually of 6 megavoltage (MV) photon beams. Single radiation isocenter is also commonly assumed in treatment planning systems (TPS).

View Article and Find Full Text PDF

The present report describes an animal model for examining the effects of radiation on a range of neurocognitive functions in rodents that are similar to a number of basic human cognitive functions. Fourteen male Long-Evans rats were trained to perform an automated intra-dimensional set shifting task that consisted of their learning a basic discrimination between two stimulus shapes followed by more complex discrimination stages (e.g.

View Article and Find Full Text PDF

High-dose-rate intraoperative radiation therapy (HDR-IORT) has historically provided effective local control (LC) for patients with unresectable and recurrent tumors. However, IORT is limited to only a few specialized institutions and it can be difficult to initiate an HDR-IORT program. Herein, we provide a brief overview on how to initiate and implement an HDR-IORT program for a selected group of patients with gastrointestinal and pelvic solid tumors using a multidisciplinary approach.

View Article and Find Full Text PDF

Outcomes for poor-risk localized prostate cancers treated with radiation are still insufficient. Targeting the "non-oncogene" addiction or stress response machinery is an appealing strategy for cancer therapeutics. Heat-shock-protein-90 (Hsp90), an integral member of this machinery, is a molecular chaperone required for energy-driven stabilization and selective degradation of misfolded "client" proteins, that is commonly overexpressed in tumor cells.

View Article and Find Full Text PDF

Purpose. To assess for differences in clinical, radiologic, and pathologic outcomes between patients with stage II-III rectal adenocarcinoma treated neoadjuvantly with conventional external beam radiotherapy (3D conformal radiotherapy (3DRT) or intensity-modulated radiotherapy (IMRT)) versus high-dose-rate endorectal brachytherapy (EBT). Methods.

View Article and Find Full Text PDF

Unlabelled: (153)Sm-ethylenediamine tetramethylene phosphonic acid ((153)Sm-EDTMP) therapy for osteosarcoma is being investigated. In this study, we analyzed the influence of (153)Sm-EDTMP administered activity (AA), osteosarcoma tumor density, mass, and the shape of the tumor on absorbed dose (AD). We also studied the biologic implication of the nonuniform tumor AD distribution using radiobiologic modeling and examined the relationship between tumor AD and response.

View Article and Find Full Text PDF

Purpose: Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide toward the goal of allowing greater freedom of needle placement.

Methods And Materials: The robot consists of a small tubular needle guide attached to a robotically controlled arm.

View Article and Find Full Text PDF

Purpose: To evaluate a prototypical system of dynamic intraoperative dosimetry for prostate brachytherapy using registered ultrasound and fluoroscopy (RUF) with a nonisocentric C-arm (GE OEC, Salt Lake City, UT) and to compare intraoperative dosimetry of RUF as well as ultrasound-based seed localization (USD) with Day 0 CT dosimetry.

Methods: Seed positions were independently determined using RUF and USD. RUF uses a radio-opaque fiducial for registration to ultrasound and 3-dimensional reconstruction of seeds relative to prostate using nonisocentric C-arm fluoroscopy.

View Article and Find Full Text PDF

Background: Since the Institute of Medicine's report, To Err is Human, was published, numerous interventions have been designed and implemented to correct the defects that lead to medical errors and adverse events; however, most efforts were largely reactive. Safety, communication, team performance, and efficiency are areas of care that attract a great deal of attention, especially regarding the introduction of new technologies, techniques, and procedures. We describe a multidisciplinary process that was implemented at our hospital to identify and mitigate hazards before the introduction of a new technique: high-dose-rate intraoperative radiation therapy, (HDR-IORT).

View Article and Find Full Text PDF

Purpose: To demonstrate the computed tomography, conformal irradiation, and treatment planning capabilities of a small animal radiation research platform (SARRP).

Methods And Materials: The SARRP uses a dual-focal spot, constant voltage X-ray source mounted on a gantry with a source-to-isocenter distance of 35 cm. Gantry rotation is limited to 120 degrees from vertical.

View Article and Find Full Text PDF

A small animal radiation platform equipped with on-board cone-beam CT and conformal irradiation capabilities is being constructed for translational research. To achieve highly localized dose delivery, an x-ray lens is used to focus the broad beam from a 225 kVp x-ray tube down to a beam with a full width half maximum (FWHM) of approximately 1.5 mm in the energy range 40-80 keV.

View Article and Find Full Text PDF

Resistance to apoptosis is a hallmark of many solid tumors, including pancreatic cancers, and may be the underlying basis for the suboptimal response to chemoradiation therapies. Overexpression of a family of inhibitor of apoptosis proteins (IAP) is commonly observed in pancreatic malignancies. We determined the therapeutic efficacy of recently described small-molecule antagonists of the X-linked IAP (XIAP) in preclinical models of pancreatic cancer.

View Article and Find Full Text PDF

Since prehistoric times, elevated temperatures have been used to treat cancer in a variety of forms. In modern times (the last 40 years) efforts have concentrated on combining heat with other anti-tumour modalities, principally ionizing radiation and some chemotherapeutic drugs. Despite the emphasis on combined therapy, rodent data relating to heat sensitivity and thermal tolerance development assumed principal importance.

View Article and Find Full Text PDF

Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed.

Methods And Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.

View Article and Find Full Text PDF

Purpose: A direct approach to the question of whether prostate tumors have an atypically high sensitivity to fractionation (low alpha/beta ratio), more typical of the surrounding late-responding normal tissue.

Methods And Materials: Earlier estimates of alpha/beta for prostate cancer have relied on comparing results from external beam radiotherapy (EBRT) and brachytherapy, an approach with significant pitfalls due to the many differences between the treatments. To circumvent this, we analyze recent data from a single EBRT + high-dose-rate (HDR) brachytherapy protocol, in which the brachytherapy was given in either 2 or 3 implants, and at various doses.

View Article and Find Full Text PDF