J Craniomaxillofac Surg
April 2024
The aim of the present study was to propose and validate FAST3D: a fully automatic three-dimensional (3D) assessment of the surgical accuracy and the long-term skeletal stability of orthognathic surgery. To validate FAST3D, the agreement between FAST3D and a validated state-of-the-art semi-automatic method was calculated by intra-class correlation coefficients (ICC) at a 95 % confidence interval. A one-sided hypothesis test was performed to evaluate whether the absolute discrepancy between the measurements produced by the two methods was statistically significantly below a clinically relevant error margin of 0.
View Article and Find Full Text PDFBackground And Objectives: Patients with dentofacial deformity (DFD) requiring orthognathic treatment have poor aesthetics, jaw function and psychological well-being, which potentially affect the quality of life. This study aimed to investigate the health-related general, oral and orthognathic quality of life, jaw function and sleep-disordered breathing at different stages of orthognathic surgical treatment.
Methods: A total of 120 consecutive patients with DFD were recruited and grouped as pre-orthodontic treatment (group 1), pre-surgery (group 2), 4 months post-surgery (group 3), 24 months post-surgery (group 4) and in addition 30 controls without DFD (group 0).
Background And Objective: Patients with dentofacial deformity often present with impaired masticatory function, orofacial pain and temporomandibular disorders (TMD). This study investigates the relationship between TMD, pain, jaw and masticatory function at different stages of orthognathic surgical (OS) treatment.
Methods: A total of 120 OS patients were prospectively recruited and grouped as pre-orthodontic (group 1), pre-surgery (group 2), 4-month post-surgery (group 3), 24-month post-surgery (group 4), in addition to 30 controls (group 0).
The literature lacks a reliable holistic approach for the three-dimensional (3D) assessment of the temporomandibular joint (TMJ) including all three adaptive processes, which are believed to contribute to the position of the mandible: (1) adaptive condylar changes, (2) glenoid fossa changes, and (3) condylar positional changes within the fossa. Hence, the purpose of the present study was to propose and assess the reliability of a semi-automatic approach for a 3D assessment of the TMJ from cone-beam computed tomography (CBCT) following orthognathic surgery. The TMJs were 3D reconstructed from a pair of superimposed pre- and postoperative (two years) CBCT scans, and spatially divided into sub-regions.
View Article and Find Full Text PDFThis systematic review aimed to determine the accuracy/stability of patient-specific osteosynthesis (PSI) in orthognathic surgery according to three-dimensional (3D) outcome analysis and in comparison to conventional osteosynthesis and computer-aided designed and manufactured (CAD/CAM) splints or wafers. The PRISMA guidelines were followed and six academic databases and Google Scholar were searched. Records reporting 3D accuracy/stability measurements of bony segments fixated with PSI were included.
View Article and Find Full Text PDFThe aim of this study was to retrospectively evaluate pharyngeal airway (PA) changes after bimaxillary surgery (BMS). Preoperative, immediate- and 5-year postoperative cone-beam computed tomography images of subjects who underwent BMS were assessed. The primary outcome variable was the PA volume.
View Article and Find Full Text PDFPurpose: Glenoid fossa morphology may change following orthognathic surgery and may subsequently affect skeletal stability and functionality, however hardly documented. Hence, the purpose of this study was to evaluate the morphological change of the glenoid fossa 2 years after bimaxillary surgery.
Methods: A case series was performed including subjects diagnosed with maxillary and/or mandibular growth disturbances, who underwent bimaxillary surgery between March 2012 and November 2017 at the Department of Oral and Maxillofacial Surgery, University Hospital of Southern Denmark, Esbjerg, Denmark.
Objectives: The purpose of the present study was to validate and compare the accuracy and reliability of surface- and voxel-based registration on the mandibular rami for long-term three-dimensional (3D) evaluation of condylar remodelling following Orthognathic Surgery.
Methods: The mandible was 3D reconstructed from a pair of superimposed pre- and postoperative (two years) cone-beam computerized tomography scans and divided into the condyle, and 21 ramal regions. The accuracy of surface- and voxel-based registration was measured by the absolute mean surface distance of each region after alignment of the pre- and postoperative rami.
Objectives: To propose and validate a reliable semi-automatic approach for three-dimensional (3D) analysis of the upper airway (UA) based on voxel-based registration (VBR).
Methods: Post-operative cone beam computed tomography (CBCT) scans of 10 orthognathic surgery patients were superimposed to the pre-operative CBCT scans by VBR using the anterior cranial base as reference. Anatomic landmarks were used to automatically cut the UA and calculate volumes and cross-sectional areas (CSA).
J Oral Maxillofac Surg
November 2021
Purpose: Three-dimensional (3D) assessment of orthognathic surgery is often time consuming, relies on manual re-identification of anatomical landmarks or is limited to non-segmental osteotomies. The purpose of the present study was to propose and validate an automated approach for 3D assessment of the accuracy and postoperative outcome of segmental bimaxillary surgery.
Methods: A semi-automatic approach was developed and validated for virtual surgical analysis (VSA) of segmental bimaxillary surgery using a pair of pre- and postoperative (2 weeks) cone-beam computerized tomography (CBCT) scans.
Purpose: (1) To present a Danish quality register (AMETO) concerning dental implant treatment for dental agenesis, assess its indicators and standards, and compare them with those acknowledged and outlined by the Institute of Medicine (IoM), World Health Organization (WHO), and Organization for Economic Cooperation and Development (OECD), classified as the quality domains efficiency, effectiveness, patient-centered care, timely care, safety, and equitability; and (2) to perform a systematic literature search and review to verify whether any quality register exists according to the six quality domains.
Materials And Methods: (1) The AMETO register is comprised of 16 process and result indicators and standards, which were compared to the six quality domains outlined by the IoM and WHO. (2) A systematic literature search was carried out using the search engines PubMed, Embase, CINAHL, Web of Science, and SveMed+.
Purpose: Little is known of the systemic effects of oral and maxillofacial surgery on the hemostatic balance, including the biochemical effects of tranexamic acid (TXA), on fibrin clot lysis. The present study investigated the effects of orthognathic surgery on fibrin lysis, fibrin structure, and D-dimer and evaluated the effect of TXA on these fibrinolytic measures.
Materials And Methods: The present double-blind, controlled, and randomized, placebo study included patients referred to the Department of Oral and Maxillofacial Surgery at the University Hospital of Southern Denmark-Esbjerg from August 2014 through September 2016.
Objective: To determine the influence of altered head or tongue posture on upper airway (UA) volumes using MRI imaging based on a new objective and validated UA evaluation protocol.
Setting And Sample Population: One supine CBCT and five sagittal MRI scans were obtained from ten subjects in different head and tongue positions: (a) supine neutral head position (NHP) with the tongue in a natural resting position with the tip of the tongue in contact with the lingual aspect of the lower incisors (TRP); (b) head extension with TRP; (c) head flexion with TRP; (d) NHP with the tip of the tongue in contact with the posterior edge of the hard palate (THP); and (e) NHP with the tip of the tongue in contact with the floor of the mouth in contact with the caruncula sublingualis.
Material And Methods: Based on a validated CBCT UA analysis, the retropalatal, oropharyngeal and the corresponding total volumes were measured from each MRI scan.
J Oral Maxillofac Surg
July 2019
Purpose: Upper airway (UA) assessment after orthognathic surgery should rely on a verified method of UA analysis. Therefore, the authors applied a new validated UA evaluation method to determine the effect of bimaxillary surgery (BMS) on UA parameters and hyoid bone and epiglottis displacement evaluated immediately and 2 years after surgery.
Materials And Methods: A retrospective cohort study was implemented of patients without obstructive sleep apnea who had undergone BMS for maxillomandibular deficiencies.
Purpose: The purpose of this randomized trial was to measure the effect of intravenously administered tranexamic acid (TXA) on intraoperative blood loss (IOB) in patients undergoing bimaxillary orthognathic surgery (OS).
Materials And Methods: The authors designed and implemented a double-blinded placebo-controlled trial composed of patients eligible for OS at the Hospital of South West Denmark (Esbjerg, Denmark) from August 2014 through September 2016. The primary predictor variable was a single intravenous dose of TXA 1 g administered preoperatively or an equivalent saline placebo.
J Craniomaxillofac Surg
October 2017
Purpose: A prospective study was performed to test the accuracy and reproducibility of the DAVID-SLS-2 scanner (SLS-2) [DAVID Vision Systems GmbH], compared to the validated 3dMDtrio scanner (3dMD) [3dMD, LLC, Atlanta, GA, USA].
Materials And Methods: The accuracy of the SLS-2 was determined through multiple scans of a mannequin face model using both scanners. The reproducibility of a protocol for achieving consistent three-dimensional (3D) face scans in live subjects was carried out using the SLS-2.
Objectives: To develop and validate a new reproducible 3D upper airway analysis based on skeletal structures not involved in the modification, which occur during orthognathic surgery.
Methods: From retrospective cohort of orthognathic surgically treated patients, pre- and postsurgical CBCT-scans of 10 post-pubertal patients were randomly selected. Two operators identified the landmarks, calculated the airway volumes, cross sections and linear measurements on the 10 scans twice at two different time intervals.
The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast establish SR micro-CT as the leading imaging modality for hard X-ray microtomography. Using SR micro-CT at voxel size 5 μm in an experimental goat mandible model, no statistically significant difference was found between the different treatment modalities nor between recipient and reconstructed bone.
View Article and Find Full Text PDFJ Oral Maxillofac Surg
September 2016
Purpose: The aim of the present retrospective study was to investigate the morbidity of screws used for intermaxillary fixation (IMF) in the treatment of mandibular fractures. A review of the published data was also performed for a comparison of outcomes. Our hypothesis was that the use of screws for IMF of mandibular fractures would result in minimal morbidity.
View Article and Find Full Text PDFObjectives: Natural head position is recommended to be optimal at cone-beam computed tomography acquisition. For standardization purposes in control of treatment outcome, it is clinically relevant to discuss, if a change of posture from natural head position may have an effect on the pharyngeal airway dimensions and morphology, during computed tomography, cone-beam computed tomography or magnetic resonance imaging acquisition. This was the aim of the present literature review study for purposes of valid evidence, which was hypothesized, to be present.
View Article and Find Full Text PDFPurpose: Bleeding volume in orthognathic surgery (OS) varies considerably, although OS comprises standardized procedures and the patient population consists of young healthy individuals. The aim of this prospective cohort study was to investigate the influence of preoperative sex-related differences in hemostatic parameters on intraoperative bleeding (IOB) volume in OS.
Materials And Methods: Patients scheduled for routine OS in our department in Esbjerg, Denmark, were included as study patients in this short-term cohort study.
Purpose: We conducted a systematic review of randomized controlled trials (RCTs) to evaluate the effectiveness of a single dose of preoperative antibiotic administered perorally, intravenously, intramuscularly, or topically for preventing infection and alveolar osteitis in lower third molar surgical extraction applying osteotomy.
Materials And Methods: The Medline, Cochrane Library, and Embase databases were searched for RCTs until August 2015. The primary outcome measure was postoperative inflammatory reactions, with a subgroup analysis of surgical site infection (SSI) and alveolar osteitis.
Purpose: The objective of the present study was to evaluate the efficacy of hemostatic adjuncts on intraoperative blood loss (IOB) in orthognathic surgery (OS) detected by randomized controlled trials (RCTs) of the highest quality.
Materials And Methods: A search of the Medline, Cochrane, Embase, and Web of Science databases was performed in January 2015, and the risk of bias was assessed using the Jadad and Delphi scales. The predictor variable was the hemostatic measures, and the main outcome variable was the total IOB volume.
The purpose of this study was to describe a refined method using high-resolution synchrotron radiation microtomography (SRmicro-CT) to evaluate osseointegration and peri-implant bone volume fraction after titanium dental implant insertion. SRmicro-CT is considered gold standard evaluating bone microarchitecture. Its high resolution, high contrast, and excellent high signal-to-noise-ratio all contribute to the highest spatial resolutions achievable today.
View Article and Find Full Text PDFClin Implant Dent Relat Res
October 2015
Background: Biomaterials are commonly used to augment the maxillary sinus floor prior to or in conjunction with dental implant installation. Recently, porous titanium granules (PTGs) have been used in oral implant surgery to stabilize implants and function as an osteoconductive matrix.
Purpose: To evaluate if PTGs can be safely used in a larger population of patients, treated by different surgeons, when sinus floor augmentation was required in conjunction with implant installation.