Publications by authors named "Ellis Jacobs"

Background: European legislation defines as "near-patient testing" (NPT) what is popularly and in other legislations specified as "point-of-care testing" (POCT). Systems intended for NPT/POCT use must be characterized by independence from operator activities during the analytic procedure. However, tools for evaluating this are lacking.

View Article and Find Full Text PDF

The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Committee on Point-of-Care Testing (C-POCT) supports the use of point-of-care testing (POCT) outside of the hospital setting performed by healthcare professionals without formal laboratory education because of its numerous benefits. However, these benefits are associated with risks that must be managed, to ensure the provision of reliable test results and minimize harm to the patient. Healthcare professionals, local regulatory bodies, accredited laboratories as well as manufacturers should actively be engaged in education, oversight and advice to ensure that the healthcare professional selects the appropriate equipment and is able to analyze, troubleshoot and correctly interpret the point-of-care (POC) test results.

View Article and Find Full Text PDF

Background: We examined the concordance of 13 commercial cardiac troponin (cTn) assays [point-of-care, high-sensitivity (hs), and conventional] using samples distributed across a continuum of results.

Methods: cTnI (11 assays) and cTnT (2 assays) were measured in 191 samples from 128 volunteers. cTn assays included Abbott (iSTAT, STAT, and hs), Alere (Cardio 3), Beckman (AccuTnI+3), Pathfast (cTnI-II), Ortho (Vitros), Siemens (LOCI, cTnI-Ultra, Xpand, Stratus CS), and Roche [4th Generation (Gen), hs].

View Article and Find Full Text PDF

Analyzers with ion-selective electrodes (ISEs) for ionized magnesium (iMg) should yield comparable and unbiased results for iMg. This IFCC guideline on sampling, measuring and reporting iMg in plasma provides a prerequisite to achieve this goal [in this document, "plasma" refers to circulating plasma and the forms in which it is sampled, namely the plasma phase of anticoagulated whole blood (or "blood"), plasma separated from blood cells, or serum]. The guideline recommends measuring and reporting ionized magnesium as a substance concentration relative to the substance concentration of magnesium in primary aqueous calibrants with magnesium, sodium, and calcium chloride of physiological ionic strength.

View Article and Find Full Text PDF

Background: Point-of-care testing (POCT) is clinical laboratory testing conducted close to the site of patient care. POCT has the potential to provide faster test results and therapeutic intervention with improved patient outcomes. However, when over-utilized or used inappropriately POCT results can be misleading and increase healthcare costs.

View Article and Find Full Text PDF

In current clinical practice, plasma and blood glucose are used interchangeably with a consequent risk of clinical misinterpretation. In human blood, glucose is distributed, like water, between erythrocytes and plasma. The molality of glucose (amount of glucose per unit water mass) is the same throughout the sample, but the concentration is higher in plasma, because the concentration of water and therefore glucose is higher in plasma than in erythrocytes.

View Article and Find Full Text PDF

Two randomized, double-blind, placebo-controlled studies assessed the analgesic efficacy of valdecoxib in patients with moderate-to-severe pain after bunionectomy. Study 1 (N = 374) assessed the efficacy of two regimens of valdecoxib on the day after surgery (valdecoxib, 40 mg, with a 20-mg redose [n = 127]; valdecoxib, 40 mg, with a placebo redose [n = 122]; and placebo/placebo [n = 125]), and study 2 (N = 478) examined the efficacy of two different multiple-dose regimens on postoperative days 2 through 5 (valdecoxib, 20 mg, twice daily [n = 160]; valdecoxib, 20 mg, once daily [n = 159]; and placebo [n = 159]). Valdecoxib provided significant pain relief and reduced the use of opioid rescue medication.

View Article and Find Full Text PDF

The proposed recommendation for measuring and reporting chloride in undiluted plasma or blood by ion-selective electrodes (ISEs) will provide results that are identical to chloride concentrations measured by coulometry for standardized normal plasma or blood samples. It is applicable to all current ISEs dedicated to chloride measurement in undiluted samples that meet the requirements. However, in samples with reduced water concentration, results by coulometry are lower than by ion-selective electrode due to volume displacement.

View Article and Find Full Text PDF

In current clinical practice, plasma and blood glucose are used interchangeably with a consequent risk of clinical misinterpretation. In human blood, glucose, like water, is distributed between erythrocytes and plasma. The molality of glucose (amount of glucose per unit of water mass) is the same throughout the sample, but the concentration is higher in plasma because the concentration of water and, therefore, glucose is higher in plasma than in erythrocytes.

View Article and Find Full Text PDF

All analyzers with ion-selective electrodes for ionized magnesium (iMg) should yield comparable and unbiased results. The prerequisite to achieve this goal is to reach consensus on sampling, measurement and reporting. The recommended guidelines for sampling, measurement and reporting iMg in plasma ("plasma" refers to circulating plasma and the forms in which it is sampled: the plasma phase of anticoagulated whole blood, plasma separated from blood cells, or serum) or blood, referring to the substance concentration of iMg in the calibrants, will provide results for iMg that are approximately 3% greater than its true concentration, and 4% less than its true molality.

View Article and Find Full Text PDF