Publications by authors named "Elizabeth Bryce"

Background: The SARS-CoV-2 pandemic stimulated the advancement and research in the field of canine scent detection of COVID-19 and volatile organic compound (VOC) breath sampling. It remains unclear which VOCs are associated with positive canine alerts. This study aimed to confirm that the training aids used for COVID-19 canine scent detection were indeed releasing discriminant COVID-19 VOCs detectable and identifiable by gas chromatography (GC-MS).

View Article and Find Full Text PDF

Surfaces on transit vehicles are frequently touched and could potentially act as reservoirs for micro-organism transmission. Regular cleaning and disinfection to minimize the spread of micro-organisms is operationally challenging due to the need to keep vehicles in circulation. The application of copper (Cu) alloys to high- touch surfaces could help reduce the risk of cross-contamination, however, little is known about the durability and efficacy of engineered copper surfaces after prolonged use.

View Article and Find Full Text PDF

Copper has well-documented antibacterial effects but few have evaluated it after prolonged use and against bacteria and viruses. Coupons from three copper formulations (solid, thermal coating, and decal applications) and carbon steel controls were subjected to 200 rounds simulated cleaning using a Wiperator™ and either an accelerated hydrogen peroxide, quaternary ammonium, or artificial sweat products. Antibacterial activity against S.

View Article and Find Full Text PDF

Background: Current measures to prevent spinal surgical site infection (SSI) lack compliance and lead to antimicrobial resistance. We aimed to examine the effectiveness of bundled preoperative intranasal photodynamic disinfection therapy (nPDT) and chlorhexidine gluconate (CHG) body wipes in the prophylaxis of spine SSIs in adults, as well as determine our institutional savings attributable to the use of this strategy and identify adverse events reported with nPDT-CHG.

Methods: We performed a 14-year prospective observational interrupted time-series study in adult (age > 18 yr) patients undergoing emergent or elective spine surgery with 3 time-specific cohorts: before rollout of our institution's nPDT-CHG program (2006-2010), during rollout (2011-2014) and after rollout (2015-2019).

View Article and Find Full Text PDF

Background: COVID-19 continues to be a public health concern and the demand for fast and reliable screening tests remains. SARS-CoV-2 infection in humans generates a specific volatile organic compound signature; this 'volatilome' could be used to deploy highly trained canine scent detection teams if they could reliably detect odours from infected individuals.

Methods: Two dogs were trained over 19 weeks to discriminate between the odours produced by breath, sweat, and gargle specimens collected from SARS-CoV-2 infected and uninfected individuals.

View Article and Find Full Text PDF

Background: We determined the burden of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in air and on surfaces in rooms of patients hospitalized with coronavirus disease 2019 (COVID-19) and investigated patient characteristics associated with SARS-CoV-2 environmental contamination.

Methods: Nasopharyngeal swabs, surface, and air samples were collected from the rooms of 78 inpatients with COVID-19 at 6 acute care hospitals in Toronto from March to May 2020. Samples were tested for SARS-CoV-2 ribonucleic acid (RNA), cultured to determine potential infectivity, and whole viral genomes were sequenced.

View Article and Find Full Text PDF

Objective: To evaluate 3 formulations of copper (Cu)-based self-sanitizing surfaces for antimicrobial efficacy and durability over 1 year in inpatient clinical areas and laboratories.

Design: Randomized control trial.

Setting: We assessed 3 copper formulations: (1) solid alloy 80% Cu-20% Ni (integral copper), (2) spray-on 80% Cu-20% Ni (spray-on) and (3) 16% composite copper-impregnated surface (CIS).

View Article and Find Full Text PDF

The objective of this study was to characterise in situ digestion kinetics and bacterial colonisation of crop sorghum ensiled with unsalable carrot or pumpkin at 0, 20 or 40% dry matter (DM). Silages with or without the application of a commercial probiotic were incubated in situ for 0, 3, 6, 9, 24 and 48 h. Calculation of in situ digestion kinetics was conducted for DM, organic matter and neutral detergent fibre (aNDF).

View Article and Find Full Text PDF

Environmental sampling was conducted at long-term care facilities to determine the extent of surface contamination with severe acute respiratory syndrome coronavirus 2 virus. Medical equipment used throughout the facility was determined to be contaminated.

View Article and Find Full Text PDF
Article Synopsis
  • The Accelerate Pheno system (AXDX) offers quick identification of pathogens (90 minutes) and antimicrobial susceptibility testing (AST; around 7 hours) from positive blood cultures, which could enhance antibiotic treatment timing.
  • In a study of 158 blood culture specimens, AXDX results were found to be available significantly faster (11.9 hours for ID and 27.7 hours for AST) compared to the standard care, with a high percentage of accurate results.
  • Clinicians could have implemented interventions up to 39 hours sooner using AXDX data, highlighting its potential to improve patient outcomes through timely and informed antibiotic adjustments.
View Article and Find Full Text PDF

Antimicrobial properties of solid copper (Cu) surfaces against various microorganisms have been demonstrated, but little is known about the durability and relative antimicrobial efficacy of different Cu formulations currently used in healthcare. The aim of this study was to assess whether three different formulations of copper-bearing alloys (integral, spray-on and Cu-impregnated surfaces) and a stainless steel control differed in their antimicrobial efficacy, durability, and compatibility with hospital-grade cleaner/disinfectants. The U.

View Article and Find Full Text PDF

The BioFire FilmArray Respiratory Panel (FA RP) is a rapid multiplexed molecular assay approved for detection of viral and atypical bacterial pathogens in nasopharyngeal specimens. This study aimed to evaluate the performance of the BioFire FilmArray Respiratory Panel v1.7 on bronchoscopy specimens.

View Article and Find Full Text PDF

The transmission of infectious microbes via bioaerosols is of significant concern for both human and animal health. However, gaps in our understanding of respiratory pathogen transmission and methodological heterogeneity persist. New developments have enabled progress in this domain, and one of the major turning points has been the recognition that cross-disciplinary collaborations across spheres of human and animal health, microbiology, biophysics, engineering, aerobiology, infection control, public health, occupational health, and industrial hygiene are essential.

View Article and Find Full Text PDF

is a ubiquitous, opportunistic, environmental gram-negative bacillus which most commonly affects cystic fibrosis and immunocompromised patients. Rarely, it can cause peritoneal dialysis (PD) exit-site infection (ESI). Information relating to predisposing factors, clinical course, and treatment options for ESIs is limited.

View Article and Find Full Text PDF
Article Synopsis
  • There has been a global rise in carbapenem-resistant Acinetobacter species (CRAs) and carbapenemase-producing variants (CPAs) in hospitals, leading Canadian health authorities to monitor these infections from 2010 to 2016.
  • Data from 58 hospitals showed a low incidence rate of CRA cases (0.02 per 10,000 patient days), with the majority of isolates being CPA and two main clusters linked to specific resistance genes (OXA-235 and OXA-23).
  • Although CRA infections were uncommon and did not increase significantly, a notable portion of cases was associated with patients who had traveled recently, and the 30-day mortality for infected
View Article and Find Full Text PDF

Background: Insufficient training in infection control and occupational health among healthcare workers (HCWs) in countries with high human immunodeficiency virus (HIV) and tuberculosis (TB) burdens requires attention. We examined the effectiveness of a 1-year Certificate Program in Occupational Health and Infection Control conducted in Free State Province, South Africa in an international partnership to empower HCWs to become change agents to promote workplace-based HIV and TB prevention.

Methods: Questionnaires assessing reactions to the program and Knowledge, Attitudes, Skills, and Practices were collected pre-, mid-, and postprogram.

View Article and Find Full Text PDF

Purpose: Urine flow cytometry (UFC) is an automated method to quantify bacterial and white blood cell (WBC) counts. We aimed to determine whether a threshold for these parameters can be set to use UFC as a sensitive screen to predict which urine samples will subsequently grow in culture.

Methodology: Urines submitted to our microbiology laboratory at a tertiary care centre from 22 July 2015-17 February 2016 underwent UFC (Sysmex UF-1000i) analysis, regular urinalysis and urine culture.

View Article and Find Full Text PDF

Background: Health workers (HWs) in resource-limited settings are at high-risk of exposure to tuberculosis (TB) at work. The aim of this study was to estimate the rate of TB disease among HWs in the Free State Province of South Africa between 2002 and 2012 and to compare demographic and clinical characteristics between HWs and the general population with TB. This study also explores the effect of occupational variables on risk of TB among HWs.

View Article and Find Full Text PDF

Environmental disinfection has become the new frontier in the ongoing battle to reduce the risk of health care-associated infections. Evidence demonstrating the persistent contamination of environmental surfaces despite traditional cleaning and disinfection methods has led to the widespread acceptance that there is both a need for reassessing traditional cleaning protocols and for using secondary disinfection technologies. Ultraviolet-C (UV-C) disinfection is one type of no-touch technology shown to be a successful adjunct to manual cleaning in reducing environmental bioburden.

View Article and Find Full Text PDF

Background: A tabletop-type ultraviolet C (UVC) light-emitting disinfecting device was evaluated for microbiologic effectiveness, safety, usability, and end-user satisfaction.

Methods: Three different inoculums of methicillin-resistant Staphylococcus aureus, Pseudomonas aeruginosa, and Acinetobacter calcoaceticus-baumannii complex strains suspended in both saline and trypticase soy broth were applied onto stainless steel carriers and electronic device surfaces in triplicate and cultured for growth after UVC disinfection. Assessments of functionality and usability were performed by biomedical and human factors engineers.

View Article and Find Full Text PDF

N95 filtering facepiece respirators are used by healthcare workers when there is a risk of exposure to airborne hazards during aerosol-generating procedures. Respirator fit-testing is required prior to use to ensure that the selected respirator provides an adequate face seal. Two common fit-test methods can be employed: qualitative fit-test (QLFT) or quantitative fit-test (QNFT).

View Article and Find Full Text PDF
Article Synopsis
  • * A total of 261 CPE isolates from 238 patients were reported, with a low incidence rate and specific carbapenemase genes (bla at 64.8% and bla at 17.6%) being the most common.
  • * The research highlighted that 21% of CPE cases were linked to patients who had received medical care during international travel, and the 30-day mortality rate for CPE cases was 17.1%, but no significant increase in CPE occurrences was
View Article and Find Full Text PDF

Toilet flushing can contribute to disease transmission by generating aerosolized bacteria and viruses that can land on nearby surfaces or follow air currents. Aerobic and anaerobic bacterial bioaerosol loads, and bacterial counts on 2 surfaces in a bathroom with a permanently installed, automated ultraviolet C (UVC) irradiation device, were significantly lower than in a comparable bathroom without the UVC device. Permanently installed UVC lights may be a useful supplementary decontamination tool in shared patient bathrooms.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionbep17v1n6k83454vraftl287i20sb4eq): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once