Background And Purpose: This study updates 2 parallel systematic reviews and meta-analyses from 2012, which established the 1-year radiostereometric (RSA) migration thresholds for tibial components of total knee replacements (TKR) based on the risk of late revision for aseptic loosening from survival studies. The primary aim of this study was to determine the (mis)categorization rate of the 2012 thresholds using the updated review as a validation dataset. Secondary aims were evaluation of 6-month migration, mean continuous (1- to 2-year) migration, and fixation-specific thresholds for tibial component migration.
View Article and Find Full Text PDFOpening remarks: These guidelines are the result of discussions within a diverse group of RSA researchers. They were approved in December 2023 by the board and selected members of the International Radiostereometry Society to update the guidelines by Valstar et al. [1].
View Article and Find Full Text PDFBackground: The influence of tibial slope on tibial component migration following total knee arthroplasty has not been widely studied, although excessive posterior slope has been implicated in some failures. As implant micromotion measured with radiostereometric analysis can indicate successful fixation, the purpose of this study was to determine the associations between tibial slope, tibial component migration, and inducible displacement.
Methods: Radiostereometric analyses at 6 visits over 2 years quantified implant migration for 200 cemented total knee arthroplasties.
Motion analysis has seen minimal adoption for orthopaedic clinical assessments. Markerless motion capture solutions, namely Theia3D, address limitations of previous methods and provide gait outcomes that are robust to clothing choice and repeatable in healthy adults. Repeatability in orthopaedic populations has not been investigated and is important for clinical utility and adoption.
View Article and Find Full Text PDFAs markerless motion capture is increasingly used to measure 3-dimensional human pose, it is important to understand how markerless results can be interpreted alongside historical marker-based data and how they are impacted by clothing. We compared concurrent running kinematics and kinetics between marker-based and markerless motion capture, and between 2 markerless clothing conditions. Thirty adults ran on an instrumented treadmill wearing motion capture clothing while concurrent marker-based and markerless data were recorded, and ran a second time wearing athletic clothing (shorts and t-shirt) while markerless data were recorded.
View Article and Find Full Text PDFBackground And Purpose: This updated meta-analysis evaluates the migration pattern of the tibial component of primary total knee replacements measured with radiostereometric analysis (RSA). We aimed to evaluate whether 6-month maximum total point motion (MTPM) values could be used instead of 1-year MTPM for RSA threshold testing and to present the pooled migration patterns for different implant designs that can be used as a benchmark.
Patients And Methods: The search included all published RSA studies on migration patterns of tibial components until 2023.
Background And Purpose: The low radiation biplanar X-ray imager (EOS imaging, Paris, France) scans patients in a weight-bearing position, provides calibrated images, and limits radiation, an asset for serial radiostereometric analysis (RSA) studies. RSA in vivo precision values have not been published for this type of imaging system, thus the goal of this study was to assess the precision of RSA in vivo utilizing a low radiation biplanar imager.
Patients And Methods: At a mean of 5 years post-surgery (range 1.
Balance tests have clinical utility in identifying balance deficits and supporting recommendations for appropriate treatments. Motion capture technology can be used to measure whole-body kinematics during balance tasks, but to date the high technical and financial costs have limited uptake of traditional marker-based motion capture systems for clinical applications. Markerless motion capture technology using standard video cameras has the potential to provide whole-body kinematic assessments with clinically accessible technology.
View Article and Find Full Text PDFMarkerless motion capture allows whole-body movements to be captured without the need for physical markers to be placed on the body. This enables motion capture analyses to be conducted in more ecologically valid environments. However, the influences of varied clothing on video-based markerless motion capture assessments remain largely unexplored.
View Article and Find Full Text PDFAims: Thresholds of acceptable early migration of the components in total knee arthroplasty (TKA) have traditionally ignored the effects of patient and implant factors that may influence migration. The aim of this study was to determine which of these factors are associated with overall longitudinal migration of well-fixed tibial components following TKA.
Methods: Radiostereometric analysis (RSA) data over a two-year period were available for 419 successful primary TKAs (267 cemented and 152 uncemented in 257 female and 162 male patients).
Kinematic analysis is a useful and widespread tool used in research and clinical biomechanics for the quantification of human movement. Common marker-based optical motion capture systems are time intensive and require highly trained operators to obtain kinematic data. Markerless motion capture systems offer an alternative method for the measurement of kinematic data with several practical benefits.
View Article and Find Full Text PDFSpatiotemporal parameters can characterize the gait patterns of individuals, allowing assessment of their health status and detection of clinically meaningful changes in their gait. Video-based markerless motion capture is a user-friendly, inexpensive, and widely applicable technology that could reduce the barriers to measuring spatiotemporal gait parameters in clinical and more diverse settings. Two studies were performed to determine whether gait parameters measured using markerless motion capture demonstrate concurrent validity with those measured using marker-based motion capture and a pressure-sensitive gait mat.
View Article and Find Full Text PDFThe clinical uptake and influence of gait analysis has been hindered by inherent limitations of marker-based motion capture systems, which have long been the standard method for the collection of gait data including kinematics. Markerless motion capture offers an alternative method for the collection of gait kinematics that presents several practical benefits over marker-based systems. This work aimed to determine the reliability of lower limb gait kinematics from video based markerless motion capture using an established experimental protocol for testing reliability.
View Article and Find Full Text PDFBackground: There are numerous reports of poor satisfaction after total knee arthroplasty (TKA), yet there is little known about when to use evidence-based models of care to improve patient outcomes.
Objective: This study aimed to characterize longitudinal changes in patient-reported satisfaction after TKA and to identify factors for early identification of poor satisfaction.
Methods: For a cohort of primary TKA surgeries (n = 86), patient-reported outcomes were captured one week before TKA and 6 weeks, 12 weeks, 6 months, and 1 and 2 years after TKA.
Background: High-viscosity (HV) bone cements have been formulated to offer potentially advantageous handling characteristics. However, alteration in the handling characteristics could influence implant fixation and survival. The primary objective of this study was to use radiostereometric analysis after total knee arthroplasty to assess the migration of the Triathlon tibial component fixed with HV cement (Simplex HV).
View Article and Find Full Text PDFBackground: The anatomic dual mobility (ADM) acetabular component was introduced because of previously described low dislocation rates for this type of construct. The shape of the anatomic cup and the motion of polyethylene liner may have implications for acetabular cup fixation and polyethylene liner wear; therefore, the purpose of this study was to assess the migration patterns and wear rates of the ADM component using radiostereometric analysis.
Methods: Uncemented ADM acetabular components were implanted in 27 patients.
Aims: A retrospective study was conducted to measure short-term linear and volumetric wear of polyethylene (PE) inserts in 101 total knee arthroplasty (TKA) patients using model-based radiostereometric analysis (MBRSA).
Patients And Methods: Nonweightbearing supine RSA exams were performed postoperatively and at six, 12, and 24 months. Weightbearing standing RSA exams were performed on select patients at 12 and 24 months.
Background: The long-term clinical success of cemented polished tapered femoral components has been demonstrated in prospective as well as registry studies. This stem design type has also been well studied with radiostereometric analysis (RSA) and provides a standard to evaluate alternative designs of polished tapered cemented femoral components. This prospective study evaluates the subsidence of a polished cemented stem with a modular neck design utilising RSA.
View Article and Find Full Text PDFBackground and purpose - Thresholds of implant migration for predicting long-term successful fixation of tibial components in total knee arthroplasty have not separated cemented and uncemented fixation. We compared implant migration of cemented and uncemented components at 1 year and as the change in migration from 1 to 2 years. Patients and methods - Implant migration of 360 tibial components measured using radiostereometric analysis was compared at 1 year and as the change in migration from 1 to 2 years in 222 cemented components (3 implant designs) and 138 uncemented components (5 implant designs).
View Article and Find Full Text PDFPhyseal closure after slipped capital femoral epiphysis fixation can be difficult to assess on two-dimensional conventional radiographs. Radiostereometric analysis offers improved motion detection over conventional radiography, whereas the EOS biplanar imager provides a means for low radiation weight-bearing images. This phantom study assessed the reliability of measuring motion using radiostereometric analysis in the EOS using a slipped capital femoral epiphysis model.
View Article and Find Full Text PDFAn in vitro radiostereometric analysis (RSA) phantom study of a total knee replacement was carried out to evaluate the effect of implementing two new modifications to the conventional RSA procedure: (i) adding a landmark of the tibial component as an implant marker and (ii) defining an implant-based coordinate system constructed from implant landmarks for the calculation of migration results. The motivation for these two modifications were (i) to improve the representation of the implant by the markers by including the stem tip marker which increases the marker distribution (ii) to recover clinical RSA study cases with insufficient numbers of markers visible in the implant polyethylene and (iii) to eliminate errors in migration calculations due to misalignment of the anatomical axes with the RSA global coordinate system. The translational and rotational phantom studies showed no loss of accuracy with the two new measurement methods.
View Article and Find Full Text PDF