Publications by authors named "Elise Fear"

Readily available animal tissue, such as ground beef, is a convenient material to represent the dielectric properties of biological tissue when validating microwave imaging and sensing hardware and techniques. The reliable use of these materials depends on the accurate characterization of their properties. In this work, the effect of physiologically relevant levels of dehydration on ex vivo tissue samples is quantified while controlling for variation within and between samples.

View Article and Find Full Text PDF

Background: Microwave imaging has been proposed for medical applications, creating maps related to water content of tissues. Breast imaging has emerged as a key application because the signals can be coupled directly into the breast and experience limited attenuation in fatty tissues. While the literature contains reports of tumor detection with microwave approaches, there is limited exploration of treatment monitoring.

View Article and Find Full Text PDF

Microwave breast imaging has seen increasing use in clinical investigations in the past decade with over eight systems having being trialled with patients. The majority of systems use radar-based algorithms to reconstruct the image shown to the clinician which requires an estimate of the dielectric properties of the breast to synthetically focus signals to reconstruct the image. Both simulated and experimental studies have shown that, even in simplified scenarios, misestimation of the dielectric properties can impair both the image quality and tumour detection.

View Article and Find Full Text PDF

We present a new formulation for a breast tissue-mimicking phantom for combined microwave and ultrasound imaging to assist breast cancer detection. Formulations based on coconut oil, canola oil, agar and glass beads were used to mimic skin and fat tissues. First, 36 recipes were fabricated, and properties were measured to determine the relationship and possible interaction between ingredients with the ultrasound and microwave properties.

View Article and Find Full Text PDF

Hydration is an important aspect of human health, as water is a critical nutrient used in many physiological processes. However, there is currently no clinical gold standard for non-invasively assessing hydration status. Recent work has suggested that permittivity in the microwave frequency range provides a physiologically meaningful metric for hydration monitoring.

View Article and Find Full Text PDF

Evaluating the quality of reconstructed images requires consistent approaches to extracting information and applying metrics. Partitioning medical images into tissue types permits the quantitative assessment of regions that contain a specific tissue. The assessment facilitates the evaluation of an imaging algorithm in terms of its ability to reconstruct the properties of various tissue types and identify anomalies.

View Article and Find Full Text PDF

Analysis of sweat is of interest for a variety of diagnosis and monitoring applications in healthcare. In this work, detailed measurements of the dielectric properties of solutions representing the major components of sweat are presented. The measurements include aqueous solutions of sodium chloride (NaCl), potassium chloride (KCl), urea, and lactic acid, as well as their mixtures.

View Article and Find Full Text PDF

This paper presents a feasibility study for a non-wearable, conformal, low cost, and disposable antenna-based sensor for non-invasive hydration monitoring using sweat. It is composed of a patch antenna implemented on a cellulose filter paper substrate and operating in the range 2⁻4 GHz. The paper substrate can absorb liquids, such as sweat on the skin, through two slots incorporated within the antenna structure.

View Article and Find Full Text PDF

A repository of anthropomorphic numerical breast models is made available for the scientific community to support research and development of microwave imaging technologies for diagnostic and therapeutic applications. These models are constructed from magnetic resonance imaging (MRI) scans acquired at our university hospital. Our 3D breast modelling method is used to translate the MRI scans into 3D models representing the geometry and microwave-frequency properties of tissues in the breast.

View Article and Find Full Text PDF

Microwave radar imaging is promising as a complementary medical imaging modality. However, the unique nature of the images means interpretation can be difficult. As a result, it is important to understand the sources of image differences, and how much variability is inherent in the imaging system itself.

View Article and Find Full Text PDF

Dehydration is a common condition characterized by a decrease in total body water. Acute dehydration can cause physical and cognitive impairment, heat stroke and exhaustion, and, if severe and uncorrected, even death. The health effects of chronic mild dehydration are less well studied with urolithiasis (kidney stones) the only condition consistently associated with it.

View Article and Find Full Text PDF

Confocal Microwave Imaging (CMI) for the early detection of breast cancer has been under development for over two decades and is currently going through early-phase clinical evaluation. The image reconstruction algorithm is a key signal processing component of any CMI-based breast imaging system and impacts the efficacy of CMI in detecting breast cancer. Several image reconstruction algorithms for CMI have been developed since its inception.

View Article and Find Full Text PDF

A second-generation monostatic radar system to measure microwave reflections from the human breast is presented and analyzed. The present system can measure the outline of the breast with an accuracy of ±1 mm and precisely place the microwave sensor in an adaptive matter such that microwaves are normally incident on the skin. Microwave reflections are measured between 10 MHz to 12 GHz with sensitivity of 65 to 75 dB below the input power and a total scan time of 30 min for 140 locations.

View Article and Find Full Text PDF

Anatomically realistic numerical breast models are essential tools for microwave breast imaging, supporting feasibility analysis, performance verification, and design improvements. Patient-specific models also assist in interpreting the results of the patient studies conducted on microwave imaging prototype systems. The proposed method employs automated and robust 3D processing techniques to construct flexible and reconfigurable breast models.

View Article and Find Full Text PDF

Purpose: The authors have developed a method to combine a patient-specific map of tissue structure and average dielectric properties with microwave tomography. The patient-specific map is acquired with radar-based techniques and serves as prior information for microwave tomography. The impact that the degree of structural detail included in this prior information has on image quality was reported in a previous investigation.

View Article and Find Full Text PDF

Purpose: The authors investigate the impact that incremental increases in the level of detail of patient-specific prior information have on image quality and the convergence behavior of an inversion algorithm in the context of near-field microwave breast imaging. A methodology is presented that uses image quality measures to characterize the ability of the algorithm to reconstruct both internal structures and lesions embedded in fibroglandular tissue. The approach permits key aspects that impact the quality of reconstruction of these structures to be identified and quantified.

View Article and Find Full Text PDF

Biomedical imaging and sensing applications in many scenarios demand accurate surface estimation from a sparse set of noisy measurements. These measurements may arise from a variety of sensing modalities, including laser or electromagnetic samples of an object's surface. We describe a state-of-the-art microwave imaging prototype that has sensors to acquire both microwave and laser measurements.

View Article and Find Full Text PDF

We present preliminary results from a method for estimating the optimal effective permittivity for reconstructing microwave-radar images. Using knowledge of how microwave-radar images are formed, we identify characteristics that are typical of good images, and define a fitness function to measure the relative image quality. We build a polynomial interpolant of the fitness function in order to identify the most likely permittivity values of the tissue.

View Article and Find Full Text PDF

Prior information about the average dielectric properties of breast tissue can be implemented in microwave breast imaging techniques to improve the results. Rapidly providing this information relies on acquiring a limited number of measurements and processing these measurement with efficient algorithms. Previously, systems were developed to measure the transmission of microwave signals through breast tissue, and simplifications were applied to estimate the average properties.

View Article and Find Full Text PDF

One factor which may be important for determining proper lesion creation during atrial ablation is catheter-endocardial contact. Little information is available that relates geometric contact, depth and angle, to ablation lesion formation. We present an electrothermal computer model of ablation that calculated lesion volume and temperature development over time.

View Article and Find Full Text PDF

Current clinical breast imaging modalities include ultrasound, magnetic resonance (MR) imaging, and the ubiquitous X-ray mammography. Microwave imaging, which takes advantage of differing electromagnetic properties to obtain image contrast, shows potential as a complementary imaging technique. As an emerging modality, interpretation of 3D microwave images poses a significant challenge.

View Article and Find Full Text PDF

Consideration of information from multiple modalities has been shown to have increased diagnostic power in breast imaging. As a result, new techniques such as microwave imaging continue to be developed. Interpreting these novel image modalities is a challenge, requiring comparison to established techniques such as the gold standard X-ray mammography.

View Article and Find Full Text PDF

Microwave approaches to breast imaging include the measurement of signals transmitted through and reflected from the breast. Prototype systems typically feature sensors separated from the breast, resulting in measurements that include the effects of the environment and system. To gain insight into transmission of microwave signals through the breast, a system that places sensors in direct contact with the breast is proposed.

View Article and Find Full Text PDF

One factor which may be important for determining proper lesion creation in an atrial ablation procedure is catheter-endocardial contact. Little information is available that relates geometric contact, depth and angle, to ablation lesion formation. We present an electrothermal computer model of ablation that calculates lesion volume and temperature development over time.

View Article and Find Full Text PDF