Background And Purpose: In external beam radiation (EBRT) of the prostate, the rectum is the dose-limiting organ at risk, and sparing of the anterior rectal wall is a prerequisite for safe delivery of doses beyond 70 Gy. Spatial sparing of the rectum can be achieved by introducing a spacer material into the retroprostatic space, thus separating the anterior rectal wall from the PTV.
Materials And Methods: Two spacer technologies, Spacer OAR, a polyethylene glycol gel and ProSpace, a saline inflated balloon, were compared in terms of spacer volume, stability, and dose reduction to the anterior rectum wall in 78 patients.