Publications by authors named "Eline K Vos"

Objectives: The aim of this study was to evaluate the technical feasibility of prostate multiparametric magnetic resonance imaging (mpMRI) at a magnetic field strength of 7 T.

Materials And Methods: In this prospective institutional review board-approved study, 14 patients with biopsy-proven prostate cancer (mean age, 65.2 years; median prostate-specific antigen [PSA], 6.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the use of low-power spectral-spatial (SPSP) pulses for prostate MRI spectroscopic imaging (MRSI) at 7T, focusing on optimizing spectral and spatial selectivity simultaneously.
  • Using a specialized double spin-echo sequence, researchers successfully conducted 3D (1)H-MRSI on prostate cancer patients and a healthy subject, without needing additional water or lipid suppression.
  • The results showed that MRSI could be carried out safely within SAR limits in about 10 minutes, revealing distinctive prostate spectral signals while highlighting some limitations in suppressing edge lipid signals.
View Article and Find Full Text PDF

Objective: The aim of this study was to determine and validate the optimal combination of parameters derived from 3-T diffusion-weighted imaging, dynamic contrast-enhanced imaging, and magnetic resonance (MR) spectroscopic imaging for discriminating low-grade from high-grade prostate cancer (PCa).

Materials And Methods: The study was approved by the institutional review board, and the need for informed consent was waived. Ninety-four patients with PCa who had undergone multiparametric MR imaging (MRI) before prostatectomy were included.

View Article and Find Full Text PDF

Purpose: Optimization of phosphorus ((31) P) MR spectroscopic imaging (MRSI) of the human prostate at 7 T by the evaluation of T1 relaxation times and the Nuclear Overhauser Effect (NOE) of phosphorus-containing metabolites.

Methods: Twelve patients with prostate cancer and one healthy volunteer were scanned on a 7 T whole-body system using a (31) P endorectal coil combined with an eight-channel (1) H body array coil. T1 relaxation times were measured using progressive saturation in a two-dimensional localization sequence.

View Article and Find Full Text PDF

Objectives: The aim of this study was to identify characteristics of phosphorus (P) spectra of the human prostate and to investigate changes of individual phospholipid metabolites in prostate cancer through in vivo P magnetic resonance spectroscopic imaging (MRSI) at 7 T.

Materials And Methods: In this institutional review board-approved study, 15 patients with biopsy-proven prostate cancer underwent T2-weighted magnetic resonance imaging and 3-dimensional P MRSI at 7 T. Voxels were selected at the tumor location, in normal-appearing peripheral zone tissue, normal-appearing transition zone tissue, and in the base of the prostate close to the seminal vesicles.

View Article and Find Full Text PDF

Objectives: The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal coil (ERC) for prostate magnetic resonance imaging at both 1.5 and 3 T.

Materials And Methods: The study was approved by the institutional review board, and written informed consent was obtained from all patients.

View Article and Find Full Text PDF

Purpose: To demonstrate that high quality T2 -weighted (T2w) turbo spin-echo (TSE) imaging of the complete prostate can be achieved routinely and within safety limits at 7 T, using an external transceive body array coil only.

Methods: Nine healthy volunteers and 12 prostate cancer patients were scanned on a 7 T whole-body system. Preparation consisted of B0 and radiofrequency shimming and localized flip angle calibration.

View Article and Find Full Text PDF

Background: A challenge in the diagnosis of prostate cancer (PCa) is the accurate assessment of aggressiveness.

Objective: To validate the performance of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of the prostate at 3 tesla (T) for the assessment of PCa aggressiveness, with prostatectomy specimens as the reference standard.

Design, Settings, And Participants: A total of 45 patients with PCa scheduled for prostatectomy were included.

View Article and Find Full Text PDF

Objectives: The objective of this study was to evaluate the apparent diffusion coefficient (ADC) of diffusion-weighted magnetic resonance (MR) imaging for the differentiation of transition zone cancer from non-cancerous transition zone with and without prostatitis and for the differentiation of transition zone cancer Gleason grade (GG) using MR-guided biopsy specimens as a reference standard.

Materials And Methods: From consecutive MR-guided prostate biopsies (2008-2012) in our referral center, we retrospectively included patients from whom diffusion-weighted MR imaging ADC values were acquired during MR-guided biopsy and whose biopsy cores had a (cancer) core length 10 mm or greater and originated from the transition zone. Two radiologists, who were blinded to the ADC data, annotated regions of interest on biopsy sampling locations of MR-guided biopsy confirmation scans in consensus.

View Article and Find Full Text PDF

Background: In many retrospective studies and large clinical trials, high-resolution, good-contrast 3DT1 images are unavailable, hampering detailed analysis of brain atrophy. Ventricular enlargement then provides a sensitive indirect measure of ongoing central brain atrophy. Validated automated methods are required that can reliably measure ventricular enlargement and are robust across magnetic resonance (MR) image types.

View Article and Find Full Text PDF