Statement Of Problem: The accuracy of printed implant surgical guides can be affected by different factors that negatively impact the planned implant position. How print orientation, storage time, and conditions influence manufacturing accuracy remains uncertain.
Purpose: The purpose of this in vitro study was to evaluate the influence of print orientation, storage conditions, and storage time on the intaglio surface accuracy of implant surgical guides manufactured by using a stereolithography (SLA) printer.
Statement Of Problem: Research-based storage guidelines for 3-dimensional (3D)-printed occlusal devices are lacking.
Purpose: The purpose of this in vitro study was to investigate the dimensional stability of the internal surface of 3D-printed occlusal devices under different storage conditions.
Material And Methods: Maxillary and mandibular dental casts were scanned and exported to a 3D printer to fabricate 30 occlusal devices.
Statement Of Problem: Studies on the fit of heat-pressed anterior lithium disilicate veneers are sparse, and whether fit is affected by glaze firing or ceramic addition is unclear.
Purpose: The purpose of this in vitro study was to evaluate and compare the marginal fit of heat-pressed anterior lithium disilicate veneers (IPS e.max Press) fabricated with the staining or cutback technique by using 3-dimensional analysis.
Int J Periodontics Restorative Dent
October 2019
The occlusal status of single-unit dental implants were evaluated using traditional and computerized methods. The type of occlusal contact in maximum intercuspation and the presence of occlusal contacts on the implant during eccentric movements were recorded. A digital sensor was used for computerized analysis of occlusion.
View Article and Find Full Text PDFStatement Of Problem: High flexural strength is one of the desirable properties for denture base resins, yet only few studies have evaluated the physical properties of newer denture bases such as computer-aided design and computer aided manufacturing (CAD-CAM) milled products.
Purpose: The purpose of this in vitro study was to compare the flexural strength of 3 different types of denture base resins: compression molded, injection molded, and CAD-CAM milled.
Material And Methods: Three groups (n=10) of acrylic denture base resins were tested: injection molded, compression molded, and CAD-CAM milled resin.
Statement Of Problem: Zirconia and lithium disilicate have been commonly used as materials for tooth-supported complete-coverage restorations. Adhesive and conventional cements have been suggested for cementation of these restorations. However, evidence on the effect of cement type on the clinical outcomes of teeth restored with zirconia or lithium disilicate restorations is unclear.
View Article and Find Full Text PDFStatement Of Problem: The accuracy of a full digital workflow using an Atlantis abutment and a milled zirconia crown; a full digital workflow with a 3Shape split-file workflow using a zirconia abutment and crown; and an interrupted digital workflow using an Atlantis abutment and a milled zirconia crown is unclear.
Purpose: The purpose of this in vitro study was to compare 2 full digital workflows relative to an interrupted workflow for restoring an implant with a custom abutment and crown. The secondary purpose of this study was to validate a digital means of measuring internal fit and marginal discrepancy using engineering software programs.
Int J Oral Maxillofac Implants
May 2017
Objective: To test whether a Maryland bridge-type splint provides adequate stability for a custom root-shaped implant to osseointegrate in a manner substantially equivalent to that of a threaded implant.
Methods: Six beagle dogs were subjected to intraoral impressions and cone beam scans that were used to fabricate custom root-shaped implants (RTIs) and crowns. Premolars in the mandible (P4) and in the maxilla (P3) were extracted, and 24 RTIs were immediately placed in extraction sockets.
Dental implants have become a widely used dental treatment approach. It is important to identify factors that can be detrimental to dental implants and the peri-implant complex. There is controversy regarding whether occlusion plays a role in the implant and peri-implant condition.
View Article and Find Full Text PDFAm J Orthod Dentofacial Orthop
December 2016
Introduction: The purpose of this study was to evaluate the effects of longitudinal flutes on miniscrew implant (MSI) stability and bone healing.
Methods: Using 11 skeletally mature New Zealand white rabbits, we placed 31 longitudinally fluted and 31 nonfluted, 3-mm-long MSIs in standardized positions in their calvaria and immediately loaded them with 100 g using nickel-titanium coil springs. Insertion torque values were obtained for each MSI placed; removal torque values were obtained for 28 MSIs that had been in place for 6 weeks and 20 MSIs that had been in place for 2 weeks.
Relatively few assessments of cranial biomechanics formally take into account variation in the material properties of cranial cortical bone. Our aim was to characterize the elastic properties of chimpanzee craniofacial cortical bone and compare these to the elastic properties of dentate human craniofacial cortical bone. From seven cranial regions, 27 cylindrical samples were harvested from each of five chimpanzee crania.
View Article and Find Full Text PDFThis is an extended case series of patients treated with an Erbium, Chromium: Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser as an adjunct to scaling for the management of intrabony defects. 46 patients with 79 angular intrabony defects associated with pocket depths of >5mm, and a mean age of 53 ± 9 years presenting with chronic periodontitis were included in the analysis. All patients underwent a localized minimally invasive closed flap surgery utilizing Er,Cr:YSGG laser therapy.
View Article and Find Full Text PDFStudies demonstrated a significant synergism between fluoride and laser in reduction of enamel solubility. However, minimal research has focused on testing the sequence of their application and no other research investigated the preventive effect of repeated applications of a combined treatment. This study investigated the effect of two applications of fluoride-laser sequence on the resistance of sound enamel to cariogenic challenge compared to one-time application.
View Article and Find Full Text PDFStatement Of Problem: Endodontic access preparation through a lithium disilicate restoration is a frequently encountered clinical situation. The common practice of repairing the accessed crown with composite resin may result in a weakened restoration.
Purpose: The purpose of this in vitro study was to determine the effect of endodontic access preparation on the fracture resistance and microstructural integrity of monolithic pressed and monolithic milled lithium disilicate complete coverage restorations.
Statement Of Problem: It is unclear which post and core system performs best when bonded to severely compromised endodontically treated teeth.
Purpose: The purpose of this study was to investigate the fracture resistance and mode of failure of severely compromised teeth restored with 3 different adhesively bonded post and core systems.
Material And Methods: Thirty extracted endodontically treated maxillary anterior teeth were randomly divided into 3 groups, CPC, gold cast post and core; TPC, titanium prefabricated post/composite resin core; and FPC, quartz fiber reinforced post/composite resin core.
Congenital adrenal hyperplasia (CAH) is an inherited autosomal recessive disorder characterized by insufficient production of cortisol. The aim of this case report was to present a child with CAH, premature exfoliation of primary teeth and accelerated eruption of his permanent teeth related to bone resorption. A 4.
View Article and Find Full Text PDFObjective: This clinical study aimed to evaluate effectiveness of a commercially available toothpaste containing potassium nitrate, sodium monoflurophosphate, and nano-hydroxyapatite as well as antioxidants phloretin, ferulic acid and silymarin in reducing dental hypersensitivity in adults.
Methods: The clinical trial enrolled patients with a history of dentin hypersensitivity. A test toothpaste was introduced into the daily routine, which included initial instruction on usage.
Purpose: This study tested the use of a dentate transport segment for the reconstruction of a large U-shaped defect in the anterior segment of the canine mandible using a novel curved reconstruction plate. The quality and quantity of bone regenerate formed by dentate versus edentulous transport segments were compared.
Materials And Methods: In 5 adult foxhound dogs, a defect of 70 to 75 mm was created in the canine mandible by excising the mandible anterior to the right and left fourth premolars.
Objective: To evaluate the effectiveness of a topically applied gel containing essential oils (menthol and thymol) and polyphenolic antioxidants (phloretin and ferulic acid) for reducing halitosis in dogs.
Animals: 20 dogs.
Procedures: A blinded crossover clinical trial was conducted.
Am J Orthod Dentofacial Orthop
June 2014
Introduction: The primary purposes of this study were to evaluate how locally delivered zoledronate affects the longitudinal stability of miniscrew implants (MSIs) and the healing of bone around MSIs.
Methods: Using a randomized split-mouth design, 60 unloaded MSIs (5 × 1.6 mm) were placed in skeletally mature male foxhound-mixed breed dogs.
Purpose: This study tested the null hypothesis that phosphate-treated titanium implants would perform no differently on mineral apposition rates (MARs), new bone-to-implant contact (new BIC), and total bone-to-implant contact (total BIC) compared to standard titanium implants.
Materials And Methods: Forty 3.3×8.
Introduction: Suture expansion stimulates bone growth to correct craniofacial deficiencies but has a high potential of treatment relapse. The objective of this study was to investigate whether there is a dose-dependent relationship between the recombinant human bone morphogenetic protein-2 (rhBMP-2) and bone formation during suture expansion.
Methods: Fifty 6-week-old male New Zealand white rabbits were randomly assigned to 5 groups to receive 0 (control), 0.
Purpose: The purpose of this study was to compare the osseointegration of dental implants placed in canine mandibular bone and in regenerated bone produced by bone transport distraction osteogenesis.
Materials And Methods: Ten adult foxhounds were divided into two groups of five animals each. In all animals, a 40-mm defect was created on one side of the mandible.
Purpose: This study tested the effects of phosphate treatment of titanium on bone volume fraction (BV/TV) at 30 to 60 Μm from the implant surface using microcomputed tomography to analyze the mineralized tissue.
Materials And Methods: Electrolytically phosphated (50/100 volts [T1/T2]) or nonphosphated 3.3- X 8-mm titanium implants (C) with sandblasted acid-etched surfaces were placed in 40 mandibular sites in five foxhounds 6 weeks after the extraction of the premolars.
Introduction: The primary aim of this study was to better understand how bone adapts to forces applied to miniscrew implants. A secondary aim was to determine whether the direction of force applied to miniscrew implants has an effect on bone surrounding the miniscrew implants.
Methods: A randomized split-mouth design, applied to 6 skeletally mature male foxhound dogs, was used to compare miniscrew implants loaded for 9 weeks with 200 or 600 g to unloaded control miniscrew implants.