The steroid submetabolome, or steroidome, is of particular interest in prostate cancer (PCa) as the dependence of PCa growth on androgens is well known and has been routinely exploited in treatment for decades. Nevertheless, the community is still far from a comprehensive understanding of steroid involvement in PCa both at the tissue and at systemic level. In this study we used liquid chromatography/high resolution mass spectrometry (LC/HRMS) backed by a dynamic retention time database DynaSTI to obtain a readout on circulating steroids in a cohort reflecting a progression of the PCa.
View Article and Find Full Text PDFLung cancer is referred to as the second most common cancer worldwide and is mainly associated with complex diagnostics and the absence of personalized therapy. Metabolomics may provide significant insights into the improvement of lung cancer diagnostics through identification of the specific biomarkers or biomarker panels that characterize the pathological state of the patient. We performed targeted metabolomic profiling of plasma samples from individuals with non-small cell lung cancer (NSLC, n = 100) and individuals without any cancer or chronic pathologies (n = 100) to identify the relationship between plasma endogenous metabolites and NSLC by means of modern comprehensive bioinformatics tools, including univariate analysis, multivariate analysis, partial correlation network analysis and machine learning.
View Article and Find Full Text PDFMetabolomics is a promising technology for the application of translational medicine to cardiovascular risk. Here, we applied a liquid chromatography/tandem mass spectrometry approach to explore the associations between plasma concentrations of amino acids, methylarginines, acylcarnitines, and tryptophan catabolism metabolites and cardiometabolic risk factors in patients diagnosed with arterial hypertension (HTA) (n = 61), coronary artery disease (CAD) (n = 48), and non-cardiovascular disease (CVD) individuals (n = 27). In total, almost all significantly different acylcarnitines, amino acids, methylarginines, and intermediates of the kynurenic and indolic tryptophan conversion pathways presented increased (p < 0.
View Article and Find Full Text PDFUntargeted metabolomics is now widely recognized as a useful tool for exploring metabolic changes taking place in biological systems under different conditions. In this article, we aim to provide a short overview of the liquid-phase separation methods hyphenated to MS to perform untargeted metabolomics of biological samples. Each approach is complemented by up-to-date literature to guide readers, as well as practical information for avoiding or fixing some of the most frequently encountered pitfalls.
View Article and Find Full Text PDFThe implementation of integrated analytical techniques to meet stringent requirements in the life sciences requires a well-developed analytical capacity. New technology in analytical equipment for the analysis of large and small molecules is continuously being developed. However, developing countries frequently struggle to keep pace with technological advancements.
View Article and Find Full Text PDFHuman immunodeficiency virus-acquired immunodeficiency syndrome continues to be a major global public health issue, having claimed almost 33 million lives to date. Due to the high cost of antiretroviral treatment, access to these drugs remains difficult for vulnerable populations, such as migrants and people living in prisons, who often do not have health insurance. These factors lead to poorer health outcomes and higher transmission rates.
View Article and Find Full Text PDFCapillary zone electrophoresis-mass spectrometry (CE-MS) is a mature analytical tool for the efficient profiling of (highly) polar and ionizable compounds. However, the use of CE-MS in comparison to other separation techniques remains underrepresented in metabolomics, as this analytical approach is still perceived as technically challenging and less reproducible, notably for migration time. The latter is key for a reliable comparison of metabolic profiles and for unknown biomarker identification that is complementary to high resolution MS/MS.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
January 2018
Unlabelled: Demetallation of metalloporphyrin molecules is one of the essential degradation reactions in photosynthesis. The effect of metalloporphyrin nature on removal of central metals from tetraphenylporphyrin complexes based on lanthanide group metals (Dy, Er, Lu, Ho) has been studied. pH values, at which the metal ions leave the metalloporphyrin complex were established using two-phase spectrophotometric titration with potentiometric pH-control.
View Article and Find Full Text PDFWe have realized the direct ionization of samples from wells of microtiter plates under atmospheric conditions for mass spectrometry analysis without any liquid delivery system or any additional interface. The microtiter plate is a commercially available 384-well plate without any modification, working as a container and an emitter for electrostatic spray ionization of analytes. The approach provides high throughput for the large batches of reactions and both the qualitative and quantitative analysis of a single compound or mixture.
View Article and Find Full Text PDFStandard addition strips were prepared for the quantitative determination of caffeine in different beverages by electrostatic spray ionization mass spectrometry (ESTASI-MS). The gist of this approach is to dry spots of caffeine solutions with different concentrations on a polymer strip, then to deposit a drop of sample mixed with an internal standard, here theobromine on each spot and to measure the mass spectrometry signals of caffeine and theobromine by ESTASI-MS. This strip approach is very convenient and provides quantitative analyses as accurate as the classical standard addition method by MS or liquid chromatography.
View Article and Find Full Text PDFImaging samples on a surface by mass spectrometry (MS) requires the combination of MS detection with a scanning mode that enables localized desorption and ionization and/or detection of sample analytes with good spatial resolution. We have developed a new mass spectrometry imaging (MSI) method based on electrostatic spray ionization. It works under ambient conditions and can be applied to a wide range of molecules providing quantitative MS analysis even in the presence of salts in excess.
View Article and Find Full Text PDFRapid Commun Mass Spectrom
November 2013
Rationale: The perfume market is growing significantly, and it is easy to find imitative fragrances of probably all types of perfume. Such imitative fragrances are usually of lower quality than the authentic ones, creating a possible threat for perfume companies. Therefore, it is important to develop efficient chemical analysis techniques to screen rapidly perfume samples.
View Article and Find Full Text PDFGel electrophoresis has been used for decades as a high-resolution separation technique for proteins and protein isomers but has been limited in the coupling with MS because of low throughput and poor automaticity compared with LC-MS. In this work, we have developed an ambient ionization strategy, electrostatic spray ionization, for in situ ionization of proteins or peptides inside a surfactant-free polyacrylamide gel. The samples can be first separated by isoelectric focusing in a gel and then quickly in situ detected by scanning the gel with the electrostatic spray ionization mass spectrometry.
View Article and Find Full Text PDFA multielectrode setup for protein OFFGEL electrophoresis that significantly improves protein separation efficiency has been developed. Here, the electric field is applied by segments between seven electrodes connected in series to six independent power supplies. The aim of this strategy is to distribute evenly the electric field along the multiwell system, and as a consequence to enhance electrophoresis in terms of separation time, resolution, and protein collection efficiency, while minimizing the overall potential difference and therefore the Joule heating.
View Article and Find Full Text PDFAn electrostatic-spray ionization (ESTASI) method has been used for mass spectrometry (MS) analysis of samples deposited in or on an insulating substrate. The ionization is induced by a capacitive coupling between an electrode and the sample. In practice, a metallic electrode is placed close to but not in direct contact with the sample.
View Article and Find Full Text PDF