Background: Data on long-term effects of catheter ablation vs antiarrhythmic drugs (AADs) on health-related quality of life (HRQoL) and atrial fibrillation (AF) burden are limited.
Objective: The study aimed to assess long-term HRQoL and rhythm data in patients with symptomatic AF.
Methods: The 75 patients who underwent ablation and 74 receiving AADs in the Catheter Ablation compared with Pharmacological Therapy for Atrial Fibrillation (CAPTAF) trial were followed for 48 months.
Background: The diagnosis of arrhythmogenic right ventricular cardiomyopathy (ARVC) in early stages is challenging. The aim of this study was therefore to investigate whether electrocardiographic imaging (ECGI) can detect epicardial conduction changes in ARVC patients and healthy mutation-carriers (M-carriers).
Method: Twelve ARVC patients, 20 M-carriers and 8 controls underwent 12-lead ECG, signal-averaged ECG, 2-dimensional echocardiography, 24-hours Holter monitoring and ECGI (body surface mapping and computer tomography with offline analysis of reconstructed epicardial signals).
Background: Early identification of patients at risk of congestive heart failure (HF) may alter their poor prognosis. The aim was therefore to test whether simple electrocardiographic variables, the P-wave and PR-interval, could predict incident HF.
Methods: The PIVUS (Prospective Investigation of the Vasculature in Uppsala Seniors) study (1016 individuals all aged 70 years, 50% women) was used to identify predictors of HF.
Atrial fibrillation (AF) is common and increases the risk for stroke and heart failure (HF). The early identification of patients at risk may prevent the development of AF and improve prognosis. This study, therefore, aimed to test the effect of the association between P-wave and PR-interval on the ECG and incident AF.
View Article and Find Full Text PDFBackground: Diagnosing arrhythmogenic right ventricular cardiomyopathy (ARVC) at an early stage can be challenging even after ECG recording and a combination of several imaging techniques. The purpose of this study was to explore if a body surface mapping (BSM) system with 252-leads could identify repolarization abnormalities and thereby diagnose early stages of ARVC.
Methods: ARVC patients, gene carriers without signs of ARVC and controls underwent a 12-lead resting ECG, signal-averaged ECG, echocardiography, 24-hours Holter monitoring, and BSM with electrocardiographic imaging (ECGI).
Aims: To assess whether the prevailing rhythm at the time of replying to symptom and health-related quality of life (HR-QoL) questionnaires impacts the findings.
Method: A total of 150 patients from the randomized Catheter Ablation Compared with Pharmacological Therapy for Atrial Fibrillation-trial, comparing atrial fibrillation (AF) ablation versus drugs, were included. The effect of the prevailing rhythm on the outcome results of the HR-QoL 36-Item Short-Form Health Survey, the symptom severity questionnaire (SSQ), and the European Heart Rhythm Association (EHRA) score for classification of AF-related symptoms was assessed.
Background: The diagnosis of ARVC remains complex requiring both imaging and electrocardiographic (ECG) techniques. The purpose was therefore to investigate whether QRS dispersion assessed by body surface mapping (BSM) could be used to detect early signs of ARVC, particularly in gene carriers.
Methods: ARVC patients, gene carriers without a history of arrhythmias or structural cardiac changes and healthy controls underwent 12-lead resting ECG, signal-averaged ECG, echocardiographic examination, 24-hours Holter monitoring, and BSM with electrocardiographic imaging.
Aims: To assess the relation between atrial fibrillation (AF) characteristics and health-related quality of life (QoL), and which AF characteristic had the greatest impact.
Method: The AF characteristics burden (percentage of time in AF), duration and number of AF episodes/month were obtained from implantable cardiac monitors during the 2-month run-in period in 150 patients included in the randomized CAPTAF trial comparing early ablation and antiarrhythmic drug therapy. The QoL was measured by the General Health and Vitality dimensions of the 36-Item Short-Form Health Survey.
Aims: The decision to implant a cardiac resynchronization therapy pacemaker (CRT-P) or a cardiac resynchronization therapy defibrillator (CRT-D) may be challenging. There are no clear guideline recommendations as no randomized study of cardiac resynchronization therapy (CRT) has been designed to compare the effects of CRT-P with those of CRT-D on patients' outcomes. In the CRT Survey II, we studied patient and implantation centre characteristics associated with the choice of CRT-P vs.
View Article and Find Full Text PDFObjectives: To compare the contemporary practice of CRT implantation in Scandinavia and Europe.
Design: We used data from The European CRT Survey II to highlight similarities and differences in the practice of CRT implantation between Europe (EUR) and Scandinavia (SCAND) and between the Scandinavian countries Denmark, Norway and Sweden. Implant data from the national pacemaker registries were used to calculate coverage.
Implantable cardioverter-defibrillator (ICD) is the standard of care for prevention of sudden cardiac death (SCD) in high-risk patients. For primary prevention of SCD, in patients with ischaemic heart disease, there is more robust data on the effect of ICD therapy compared with patients with non-ischaemic heart disease, but current real-life practice may differ substantially. The aim of this European Heart Rhythm Association survey was to evaluate the clinical practice regarding implantation of ICD for primary prevention among European countries in patients with non-ischaemic and ischaemic heart disease.
View Article and Find Full Text PDFThe European Snapshot Survey on Procedural Routines for Electronic Device Implantation (ESS-PREDI) was a prospective European survey of consecutive adults who had undergone implantation/surgical revision of a cardiac implantable electronic device (CIED) on chronic antithrombotic therapy (enrolment March-June 2015). The aim of the survey was to investigate perioperative treatment with oral anticoagulants and antiplatelets in CIED implantation or surgical revision and to determine the incidence of complications, including clinically significant pocket haematomas. Information on antithrombotic therapy before and after surgery and bleeding and thromboembolic complications occurring after the intervention was collected at first follow-up.
View Article and Find Full Text PDFEuropace
March 2016
The purpose of this patient survey was to analyse the knowledge about blood thinning medications relative to gender, age, education, and region of residence in patients with atrial fibrillation (AF). A total of 1147 patients with AF [mean age 66 ± 13 years, 529 (45%) women] from eight European countries responded to this survey. Most patients understood that the indication for anticoagulation therapy was to 'thin the blood', but 8.
View Article and Find Full Text PDFThe aim of this European Heart Rhythm Association (EHRA) survey was to collect data on the use of wearable cardioverter-defibrillators (WCDs) among members of the EHRA electrophysiology research network. Of the 50 responding centres, 23 (47%) reported WCD use. Devices were fully reimbursed in 17 (43.
View Article and Find Full Text PDFClinical practice should follow guidelines and recommendations mainly based on the results of controlled trials, which are often conducted in selected populations and special conditions, whereas clinical practice may be influenced by factors different from controlled scientific studies. Hence, the real-world setting is better assessed by the observational registries enrolling patients for longer periods of time. However, this may be difficult, expensive, and time-consuming.
View Article and Find Full Text PDFThe European Snapshot Survey on Procedural Routines in Atrial Fibrillation Ablation (ESS-PRAFA) is a prospective, multicentre snapshot survey collecting patient-based data on current clinical practices during atrial fibrillation (AF) ablation. The participating centres were asked to prospectively enrol consecutive patients during a 6-week period (from September to October 2014). A web-based case report form was employed to collect information of patients and data of procedures.
View Article and Find Full Text PDFThe purpose of this European Heart Rhythm Association survey was to assess the attitude, level of education, and knowledge concerning oral anticoagulants (OACs) among patients with atrial fibrillation (AF) taking vitamin K antagonists (VKAs), non-VKA oral anticoagulants (NOACs) or antiplatelets. A total of 1147 patients with AF [mean age 66 ± 13 years, 529 (45%) women] from 8 selected European countries responded to this survey. The overall use of OACs and antiplatelets was 77 and 15.
View Article and Find Full Text PDFThe purpose of this European Heart Rhythm Association (EHRA) survey was to assess clinical practice in the management of ventricular tachycardia (VT). The data are based on an electronic questionnaire sent to the members of the EHRA Research Network. Responses were received from 31 centres in 16 countries.
View Article and Find Full Text PDFThe purpose of this EP wire is to examine clinical practice in the field of screening of patients of risk of ventricular arrhythmias and/or sudden cardiac death (SCD) in European countries. A systematic screening programme existed in the majority of centres and was organized by a multidisciplinary dedicated team or by an activity programme of implantable cardioverter-defibrillator (ICD) or heart failure clinics. In particular, high-risk subgroups of patients with ischaemic and non-ischaemic cardiomyopathy ICD implantation are considered strongly indicated within 90 days of myocardial revascularization or initial diagnosis.
View Article and Find Full Text PDFThe purpose of this survey was to assess clinical practice in management of cardiac arrhythmias in elderly patients (age ≥75 years) in the European countries. The data are based on an electronic questionnaire sent to the European Heart Rhythm Association Research Network members. Responses were received from 50 centres in 20 countries.
View Article and Find Full Text PDFThe purpose of this European Heart Rhythm Association (EHRA) EP wire survey was to evaluate the implementation of the current guidelines for cardiac pacing and cardiac resynchronization therapy (CRT) in Europe. A total of 48 centres replied to the survey, 34 of them (71%) were university hospitals. All responding centres implement CRT in patients with classical indications, i.
View Article and Find Full Text PDFSeveral kinds of electrocardiogram monitoring systems are now available in the clinical practice. The aim of this European Heart Rhythm Association (EHRA) survey was to assess the use of different monitoring techniques in the evaluation of patients with unexplained syncope, palpitations, and in those with established diagnosis of atrial fibrillation. Forty-five centres in Europe answered the questionnaire and the majority (78%) were university hospitals.
View Article and Find Full Text PDFCardiac device implantation is the most common of all invasive cardiac electrophysiological procedures. Over 250 000 devices are implanted each year in Europe. The purpose of this European Heart Rhythm Association (EHRA) survey was to assess the facilities, personnel, and protocols of members of the EHRA electrophysiology (EP) research network involved in device implantation.
View Article and Find Full Text PDF