Publications by authors named "Elena Abellan Rubio"

The bioavailability of ophthalmic therapeutics is reduced because of the presence of physiological barriers whose primary function is to hinder the entry of exogenous agents, therefore also decreasing the bioavailability of locally administered drugs. Consequently, repeated ocular administrations are required. Hence, the development of drug delivery systems that ensure suitable drug concentration for prolonged times in different ocular tissues is certainly of great importance.

View Article and Find Full Text PDF

Background: The latest generation in titanium clip application systems, the AnastoClip Vessel Closure System (VCS; LeMaitre Vascular, Burlington, MA), allows surgeons to perform vascular anastomosis more easily and faster than conventional sutures. This system may become the option of choice for vascular reconstruction in pediatric surgery where, as in the case transplant surgery, decreasing vascular occlusion times may influence outcome. The aim of this study was to determine whether VCS metallic clips would allow shorter anastomosis times than conventional interrupted polypropylene or running polyglycolic acid suturing in end-to-end anastomosis performed in the abdominal cava of young pigs.

View Article and Find Full Text PDF

Background/purpose: Our aim was to perform a macroscopic and imaging (ultrasonographic and angiographic) evaluation of vascular closure stapler (VCS) metallic clips for renal transplantation in growing piglets to assess their role for transplantation surgery in young children. If these techniques are to be useful, it is necessary to prove that their use avoids one of the main pitfalls of conventional sutures in this setting, namely lack of growth in the suture line.

Methods: Twenty-four piglets were used for this study.

View Article and Find Full Text PDF

Introduction: When performing vascular reconstruction in growing elements, specifically in paediatric transplant surgery, where a short vascular occlusion time is mandatory, master and easily handled suturing methods are needed. Thus the present study compares conventional continuous suturing with polypropylene and dexon versus easier and faster to apply titanium clips in heterotopic renal autotransplants.

Material And Methods: 24 growing pigs were used for this study.

View Article and Find Full Text PDF

Objective: To present a new simulator designed at the Minimally Invasive Surgery Centre (Cáceres) which offers an integral, effective and viable training system that can be used for learning microsurgical techniques.

Study Design: A square methacrylate block was used. Animal jaws were fixed to the sides by means of butterfly screws.

View Article and Find Full Text PDF