Recently, a numerical method was proposed to correct the imaging plate (IP) response to (90)Sr concentration in tooth samples, depending on the sample thickness. This is important to quantify any (90)Sr concentration in teeth, which in turn is necessary to determine any (90)Sr incorporation of a person retrospectively. Although the final goal will be to evaluate the (inhomogeneous) spatial distribution of (90)Sr inside tooth samples precisely, the present study was restricted -- as a first step -- to the evaluation of (90)Sr in teeth assuming a uniform (90)Sr distribution.
View Article and Find Full Text PDFThe influence of X-ray baggage scanning on electron spin resonance (ESR) dosimetry studies around the Semipalatinsk Nuclear Test Site (SNTS) has been examined at Incheon Airport in Korea, which is a transfer point of the routes from Kazakhstan to Japan. Utilized dosimeters are Japanese human tooth enamel for ESR and glass dosimeters. The difference between the estimated doses with the X-ray scan and those without it is below the evaluation errors for both ESR and the glass dosimeters.
View Article and Find Full Text PDFThe method of electron paramagnetic resonance (EPR) dosimetry was applied to the enamel of the teeth extracted from the residents of the Dolon and Bodene settlements of the Beskaragay district, which is the area adjacent to the radioactive fallout of the most contaminating nuclear test of 1949. The individual accidental radiation doses due to the fallout were obtained from the amplitude of the radiation induced EPR signal from the CO2- radical using the calibration method, after determining the parameters of EPR measurements to obtain the best reproducibility of the signal intensities. It was shown that after subtracting the natural background dose from the total absorbed dose obtained by EPR the residents of Dolon and Bodene received accidental radiation doses up to 356 mGy with an average value of 74.
View Article and Find Full Text PDFThe method of electron paramagnetic resonance (EPR) spectroscopy for tooth enamel is applied to individual radiation dose determination to residents of two villages (Dolon and Mostik) in the vicinity of the Semipalatinsk nuclear test site in Kazakhstan. These villages are located near the central axis of the radioactive fallout trace of the most contaminating surface nuclear test conducted in 1949. It is found that excess doses obtained by subtraction of natural background dose from dose absorbed in enamel range up to 440 mGy to residents of Dolon, whose enamel was formed before 1949, and do not exceed 120 mGy to younger residents.
View Article and Find Full Text PDFThe Imaging Plate (IP) technique which uses the Monte Carlo code, MCNP, to convert IP response to 90Sr concentration with varied thickness of the standard source has been proposed in this study. In order to verify the validity of simulation calculation in the proposed method, the radial distribution of IP signal has been compared between calculation and experiment. The result is, they are in good agreement.
View Article and Find Full Text PDF