The hearing healthcare industry is evolving rapidly. A framework addressing provision options in contemporary hearing care could assist clinician and client navigate their options to find the most appropriate solution for each individual. A PRISMA approach was used followed by mapping, validation, and thematic analysis to produce a framework to better describe and discuss service and product delivery options in contemporary hearing care.
View Article and Find Full Text PDFThis research was conducted to evaluate the efficacy of an online speech perception test (SPT) for the measurement of hearing and hearing aid fitting in comparison with conventional methods. Phase 1 was performed with 88 people to evaluate the SPT for the detection of significant hearing loss. The SPT had high sensitivity (94%) and high selectivity (98%).
View Article and Find Full Text PDFThe objective of this study was to compare the psychophysical performance of patients using the Nucleus Contour electrode array with that of patients using the straight banded-electrode array. In particular, we wished to consider how psychophysical parameters would differ for an electrode array positioned closer to the modiolus, and how this might influence both patient benefits and the design of speech processing strategies. Nine subjects participated in the study: four used the Nucleus straight array and five used the Nucleus Contour electrode array.
View Article and Find Full Text PDFThe feasibility of using the electrically evoked compound action potential (ECAP), measured with the NRT system (Neural Response Telemetry) and the NRT software (version 2.04), to quantify the longitudinal spread of neural excitation was examined in four subjects fitted with the Nucleus C124M cochlear implant. The ECAP and psychophysical forward-masking profiles were measured using stimulation on each of three electrodes, in basal, middle and apical positions.
View Article and Find Full Text PDFThis study introduces and evaluates a method for measurement of the longitudinal spread of electrically evoked neural excitation in the cochlea, using the Neural Response Telemetry system (NRT) available with the Nucleus((R)) 24 cochlear implant system. The recently released version of the NRT software (version 3.0) enables presentation of the 'masker' and 'probe' on different electrodes.
View Article and Find Full Text PDFObjective: The study investigated the hypothesis that threshold and comfortable levels recorded from cochlear implant patients would reduce, and dynamic range increase, as distance of the electrode from the modiolar wall (radial distance) decreases. Two groups of cochlear implant patients participated; one group using the Nucleus' 24 Contour electrode array, and one group using the Nucleus standard straight (banded) array. The Nucleus 24 Contour array has been shown in temporal bone studies to lie closer to the modiolus than the banded array.
View Article and Find Full Text PDF