Introduction: Repetitive focal and rotational activation patterns are currently used as additional ablation targets for atrial fibrillation (AF). However, there is no evidence that all these detected targets are actual sources of AF. In this paper, we present an approach that detects and ranks AF activation patterns not only based on the degree of pattern repetitiveness but also on the extent to which they are able to entrain their vicinity.
View Article and Find Full Text PDFBackground: Maintaining the quality and integrity of student assessments, especially in professional fields like nursing, is critical. Managing moderation processes across large teams poses social and logistical challenges, further complicated by varying quality and clarity of institutional guidelines. Systematic reviews on moderation practices in higher education are scarce.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
November 2024
Adsorption remediation is an energy-efficient water treatment technology that utilizes the adsorption properties of a biosorbent to remove various pollutants. While many articles have explored the high surface area and adsorption capacity of activated carbon for remediating aquatic systems, few have delved into the environmental impact of its synthesis, which often involves HPO, a highly toxic activating agent. In this study, we present a groundbreaking alternative to activated carbon for the adsorption and remediation of aquatic waste that doesn't rely on chemical products.
View Article and Find Full Text PDFOsteoarthritis (OA) is a degenerative disease that affects the quality of life in elderly and young populations. Current therapies using corticosteroids and non-steroidal anti-inflammatory drugs via parenteral or oral routes show limited ability to retard progression of the disease and achieve long term effectiveness and safety. Herein, the potential of MT-Cur combinatorial nano-formulations in OA management was explored for the first time.
View Article and Find Full Text PDFBackground: Innovative models are required to maximize nursing student placements in environments of shrinking budgets, increasing hospital demands, and casualization and aging of the workforce. This article reports the success of a service-academic partnership in a dedicated education unit.
Method: This cross-sectional observational study in a regional hospital analyzed survey data using validated tools completed by buddy nurses ( = 80) and postplacement evaluation completed by students ( = 102) and the nurse leadership team ( = 17).
Aims: Previous clinical studies on pulmonary vein isolation (PVI) with a radiofrequency balloon (RFB) reported safe and effective procedures using conventional ablation settings with 20/60 s RF delivery via posterior/anterior (PST/ANT) electrodes. The latest evidence suggests that reducing the application time to 15 s (s) on the posterior wall when facing the oesophageal region is as effective as applying 20 s. To prospectively assess whether reducing RF time on PST/ANT segments to 15/45 s can ensure sufficient quality of lesion metrics and compare the new shortened ablation settings with the conventional one in terms of safety, and effectiveness at 1-year.
View Article and Find Full Text PDFPurpose: This study aims to assess the status of radiation oncology peer review procedures across the Middle East, North Africa, and Türkiye (MENAT) region.
Methods: A cross-sectional electronic survey was conducted among radiotherapy centers in the MENAT region in March 2024. It assessed peer review practices, departmental demographics, perceived importance of peer review, and potential barriers.
Background: Children's mental health, including their well-being, is a major public health concern, as the burden of related disorders may last throughout one's life. Although epidemiological mental health surveillance systems for children and adolescents have been implemented in several countries, they are sorely lacking in France.
Objective: This study aims to describe the first step of the implementation of a novel surveillance system in France called Enabee (Etude nationale sur le bien-être des enfants), which focuses on the issue of mental health in children.
Water pollution has remained a pressing concern in recent years, presenting multifaceted challenges in search of effective mitigation strategies. Our study, which targets mitigating pollution caused by 2,4,5-trichlorophenoxyacetic acid (2,4,5-T), a significant aquatic pollutant, is innovative in its approach. We have identified adsorption as a promising, cost-effective method for its removal.
View Article and Find Full Text PDFIntroduction: Esophageal safety following radiofrequency (RF) left atrial (LA) linear ablation has not been established. To determine the esophageal safety profile of LA linear RF lesions, we performed systematic esophagogastroduodenoscopy in all patients with intraesophageal temperature rise (ITR) ≥ 38.5°C.
View Article and Find Full Text PDFWater pollution due to dyes in the textile industry is a serious environmental problem. During the finishing stage, Congo red (CR) dye, water-soluble, is released into wastewater, polluting the water body. This study explores the effectiveness of utilizing a composite composed of Safi raw clay and chitosan to remove an anionic dye from synthetic wastewater.
View Article and Find Full Text PDFBackground: A large-scale industrial fire occurred in Rouen, France, in 2019. This study assessed the health-related quality of life of people exposed to its consequences 1 year later.
Methods: The study population comprised inhabitants of the exposed area and a non-exposed area.
Aims: Pulsed field ablation (PFA) is a promising ablation technique for pulmonary vein isolation (PVI) with appealing advantages over radiofrequency (RF) including speed, tissue selectivity, and the promise of enhanced durability. In this study, we determine the procedural performance, efficacy, safety, and durability of PFA and compare its performance with a dataset of optimized RF ablation.
Methods And Results: After propensity score matching, we compared 161 patients who received optimized RF-guided PVI in the PowerPlus study (CLOSE protocol) with 161 patients undergoing PFA-guided PVI for paroxysmal or persistent atrial fibrillation (AF; pentaspline basket catheter).
Background: COVID-19 vaccine acceptance among refugees in the Arab region remains low. This study aimed to examine the prevalence, reasons and predictors of intention to refuse the COVID-19 vaccine among older Syrian refugees in Lebanon.
Methods: A nested cross-sectional study within a longitudinal study among older Syrian refugees in Lebanon.
People tend to spend more time in front of their screens, which can have repercussions on their social life, physical and mental health. This topic has mainly been studied in adolescents. Therefore, our study tested associations between the use of video games, social media and online dating leading to sexual relations (ODLSR), and symptoms of anxiety and/or depression among adults aged 25 and over.
View Article and Find Full Text PDFBackground: Early recurrence of atrial tachyarrhythmia (ERAT) is associated with ablation-induced proarrhythmogenic inflammation; however, existing studies used intermittent monitoring or nonoptimized radiofrequency (RF) applications (noncontiguous or without ablation index target value).
Objective: The purpose of this study was to investigate the relationship between ERAT and late recurrence based on insertable cardiac monitor (ICM) data.
Methods: We compiled data from Close-To-Cure and Close Maze studies, which enrolled patients who underwent RF ablation for paroxysmal or persistent atrial fibrillation (AF).
Background: In patients with persistent atrial fibrillation (PersAF), catheter ablation aiming for pulmonary vein isolation (PVI) is associated with moderate clinical effectiveness. We investigated the benefit of continuing previously ineffective class 1C or 3 antiarrhythmic drug therapy (ADT) in the setting of a standardized PVI-only ablation strategy.
Methods: In this multicenter, randomized controlled study, patients with PersAF (≥7 days and <12 months) despite ADT were prospectively randomized 1:1 to PVI with ADT continued versus discontinued beyond the blanking period (ADT ON versus ADT OFF).
Stereotactic body radiation therapy (SBRT) is a precise and conformal radiation therapy (RT) that aims to deliver a high dose of radiation to the tumor whilst sparing surrounding normal tissue, making it an attractive option for head and neck cancer (HNC) patients who are not suitable for the traditional long course of RT with comprehensive RT target volume. Definitive SBRT for HNC has been investigated in different settings, including early stage glottis cancer, and as an alternative to brachytherapy boost after external beam RT. It is also used as a primary treatment option for elderly or medically unfit patients.
View Article and Find Full Text PDFPrevious clinical studies on pulmonary vein isolation (PVI) with radiofrequency balloons (RFB) reported safe and effective procedures for a 20 s RF delivery via posterior electrodes. Recent recommendations from the manufacturer suggest reducing the application time to 15 s on the posterior wall (PW) when facing the esophagus region. Here, we retrospectively assess whether 15 s of RF delivery time on posterior electrodes is safe while still ensuring lesion metrics of sufficient quality.
View Article and Find Full Text PDFAims: Cryoballoon (CB) ablation is the mainstay of single-shot pulmonary vein isolation (PVI). A radiofrequency balloon (RFB) catheter has recently emerged as an alternative. However, these two technologies have not been compared.
View Article and Find Full Text PDFBackground: Persistent shock-resistant atrial fibrillation (AF) is a challenging entity, with modest results from catheter ablation according to conventional survival analysis.
Objectives: The aim of this study was to determine the effect of catheter ablation on atrial tachyarrhythmia (ATA) burden in persistent AF patients undergoing first-time ablation with the use of an implantable cardiac monitor (ICM).
Methods: Patients with drug-resistant ongoing persistent AF and at least 1 previous failed cardioversion were implanted with an ICM 2 months before the procedure.
Background: The Myval balloon-expandable (BE) valve has shown encouraging early clinical data in terms of safety and efficacy. Comparative data with other well-established contemporary valves are nonetheless still scarce. This study aims to compare the performance of the Myval BE valve with the Evolut self-expanding (SE) valve.
View Article and Find Full Text PDFBackground: Very high-power, short-duration (90-W/4-second) ablation for pulmonary vein isolation (PVI) may reduce procedural times. However, shorter applications with higher power may impact lesion quality.
Objectives: In this multicenter, randomized controlled trial, the authors compared procedural efficiency, efficacy, and safety of PVI using 90-W/4-second ablation to 35/50-W ablation.