Fluxes of some Volatile Organic Compounds (VOC) from grass were measured at a golf course in western Sweden, using the Relaxed Eddy Accumulation (REA) technique. The sampling was done by collecting VOC onto adsorbent tubes and the analysis was performed by thermal desorption followed by GC/MS. High emissions were observed after cutting.
View Article and Find Full Text PDFDeterminations of PCB were carried out as part of a project aimed at developing cleanup methods for PCB-containing elastic sealant used in outdoor joints between concrete blocks. The goals of the project were to develop methods, which minimise the spread of PCB to the outdoor environment and to indoor air, and which keep the PCB levels as low as reasonably possible in the workplace environment whilst removing the elastic sealant. The following PCB determinations were carried out: (1) concentration in the elastic sealant; (2) concentration in the concrete close to the sealant; (3) concentration in soil; (4) concentration in the indoor air; and (5) concentration in the air in the workplace environment.
View Article and Find Full Text PDFData of chemical emissions from flooring materials have been collected and investigated in a database known as METS. The emission tests are performed using the Field and Laboratory Emission Cell (FLEC). The emission rates of total volatile organic compounds (TVOC) in the boiling point range of hexane to octadecane varies from around 4,000 micrograms/(m2.
View Article and Find Full Text PDF