Publications by authors named "Eisenkraft A"

Community-based organizations (CBOs) are critical for delivering evidence-based interventions (EBIs) to address cancer inequities. However, a lack of consensus on the core skills needed for this work often hinders capacity-building strategies to support EBI implementation. The disconnect is partly due to differing views of EBIs and related skills held by those typically receiving versus developing capacity-building interventions (here, practitioners and academics, respectively).

View Article and Find Full Text PDF

Intradialytic hypotension (IDH) is a severe complication of hemodialysis (HD) with a significant impact on morbidity and mortality. In this study, we used a wearable device for the continuous monitoring of hemodynamic vitals to detect hemodynamic changes during HD and attempted to identify IDH. End-stage kidney disease patients were continuously monitored 15 min before starting the session and until 15 min after completion of the session, measuring heart rate (HR), noninvasive cuffless systolic and diastolic blood pressure (SBP and DBP), stroke volume (SV), cardiac output (CO), and systemic vascular resistance (SVR).

View Article and Find Full Text PDF

Background: Recent technological developments enable big data-driven insights on diurnal changes. This study aimed to describe the trajectory of multiple and advanced parameters using a medical-grade wearable remote patient monitor.

Methods: Parameters were monitored for 24 h in 256 ambulatory participants who kept living their normal life.

View Article and Find Full Text PDF

Body temperature is essential for diagnosing, managing, and following multiple medical conditions. There are several methods and devices to measure body temperature, but most do not allow continuous and prolonged measurement of body temperature. Noninvasive skin temperature sensor combined with a heat flux sensor, also known as the "double sensor" technique, is becoming a valuable and simple method for frequently monitoring body temperature.

View Article and Find Full Text PDF

Combat soldiers are currently faced with using a hearing-protection device (HPD) at the cost of adequately detecting critical signals impacting mission success. The current study tested the performance of the Perforated-Concave-Earplug (pCEP), a proof-of-concept passive HPD consisting of a concave bowl-like rigid structure attached to a commercial roll-down earplug, designed to improve sound localization with minimal compromising of noise attenuation. Primarily intended for combat/military training settings, our aim was an evaluation of localization of relevant sound sources (single/multiple gunfire, continuous noise, spoken word) compared to 3M™-Combat-Arms™4.

View Article and Find Full Text PDF

Background: Respiratory rate (RR) is used for the diagnosis and management of medical conditions and can predict clinical changes. Heavy workload, understaffing, and errors related to poor recording make it underutilized. Wearable devices may facilitate its use.

View Article and Find Full Text PDF

Introduction: Community-based organizations (CBOs) are important equity-promoting delivery channels for evidence-based interventions (EBIs). However, CBO practitioners often cannot access needed support to build EBI skills. Additionally, the capacity-building literature is hindered by inconsistent definitions, limited use of validated measures, and an emphasis on the perspectives of EBI developers versus implementers.

View Article and Find Full Text PDF

Background: Community-based organizations (CBOs) are critical partners in delivering evidence-based interventions (EBIs) to address cancer inequities. However, CBO practitioners do not typically have access to opportunities to build the necessary capacity (skills, knowledge, motivation, and resources) for using EBIs. Although capacity-building interventions can offer a solution, inconsistent definitions and measurements of capacity limit the ability to develop and evaluate such efforts.

View Article and Find Full Text PDF

Background: Continuous monitoring of ECG, respiratory rate, systolic and diastolic blood pressure, pulse rate, cardiac output, and cardiac index is important in patients with ST-elevation myocardial infarction (STEMI) admitted to the intensive cardiac care unit (ICCU). However, monitoring these parameters in this setting and in these patients using noninvasive, wireless devices has not been conducted so far. We aimed to assess the use of a novel noninvasive continuous monitoring device in STEMI patients admitted to the ICCU.

View Article and Find Full Text PDF

Currently-used tools for early recognition of clinical deterioration have high sensitivity, but with low specificity and are based on infrequent measurements. We aimed to develop a pre-symptomatic and real-time detection and warning tool for potential patients' deterioration based on multi-parameter real-time warning score (MPRT-WS). A total of more than 2 million measurements were collected, pooled, and analyzed from 521 participants, of which 361 were patients in general wards defined at high-risk for deterioration and 160 were healthy participants allocation as controls.

View Article and Find Full Text PDF

Having a beard is an independent predictor of difficult ventilation by face mask. This study evaluates the efficacy of a novel intra-oral Bag-Valve-Guedel Adaptor (BVGA) in anaesthetized bearded patients. Patients with ASA score 1-2, scheduled for elective surgery, were recruited for this prospective, crossover trial.

View Article and Find Full Text PDF

There are no clear guidelines for diuretic administration in heart failure (HF), and reliable markers are needed to tailor treatment. Continuous monitoring of multiple advanced physiological parameters during diuresis may allow better differentiation of patients into subgroups according to their responses. In this study, 29 HF patients were monitored during outpatient intravenous diuresis, using a noninvasive wearable multi-parameter monitor.

View Article and Find Full Text PDF

Introduction: Combat ground maneuvers consist of various platforms and have several environmental characteristics, influenced by the terrain, the operational mission, and the force's capabilities. This study assesses data on injuries sustained during urban warfare, aiming to evaluate the relationship between injury characteristics, maneuver platform, and personal protective gear on the battlefield.

Materials And Methods: IDF soldiers injured infantry soldiers from the "Cast Lead" and the "Protective Edge" operations in the Gaza Strip (2008-2009 and 2014, respectively) were divided into four groups according to the maneuver platform and the environment: mounted infantry (armored and unarmored vehicle) and dismounted infantry (urban and open area).

View Article and Find Full Text PDF

Organophosphates (OPs) are inhibitors of acetylcholinesterase and have deleterious effects on the central nervous system. Clinical manifestations of OP poisoning include convulsions, which represent an underlying toxic neuro-pathological process, leading to permanent neuronal damage. This neurotoxicity is mediated through the cholinergic, GABAergic and glutamatergic (NMDA) systems.

View Article and Find Full Text PDF

Penetrating abdominal injury is a major cause of death in trauma. Sodium alginate hydrogel, a hemostatic agent, offers a platform for targeting both mechanical and biological injuries. The current study assessed the effect of Very Low Viscosity (high) G (VLVG) alginate following abdominal trauma in a swine model of penetrating abdominal injury.

View Article and Find Full Text PDF

Vital signs obtained by photoplethysmography-based devices might be influenced by subcutaneous fat and skin color. This observational comparison study aimed to test the accuracy of blood pressure (BP) measurements between a photoplethysmography-based device and cuff-based BP device in ambulatory individuals, coming for a routine BP checkup. Systolic BP (SBP) and diastolic BP (DBP) measurements were stratified based on sex, BMI (<25; 25 ≤BMI<30; 30 ≤kg/m), and skin color (types 1-3 and 4-6 by the Fitzpatrick scale).

View Article and Find Full Text PDF

Background: Social distancing policy was introduced in Israel in 2020 to reduce the spread of coronavirus disease 2019 (COVID-19). The aim of this study was to analyze the effect of social distancing on other infections in children, by comparing disease rate and healthcare utilization before and after social distancing.

Methods: This was a before-and-after study.

View Article and Find Full Text PDF

Background: Clinical trial guidelines for assessing the safety of vaccines, are primarily based on self-reported questionnaires. Despite the tremendous technological advances in recent years, objective, continuous assessment of physiological measures post-vaccination is rarely performed.

Methods: We conducted a prospective observational study during the mass vaccination campaign in Israel.

View Article and Find Full Text PDF

Objectives: Cardiac output (CO) measurements in the ICU are usually based on invasive techniques, which are technically complex and associated with clinical complications. This study aimed to compare CO measurements obtained from a noninvasive photoplethysmography-based device to a pulse contour cardiac output device in ICU patients.

Design: Observational, prospective, comparative clinical trial.

View Article and Find Full Text PDF

Early detection of influenza may improve responses against outbreaks. This study was part of a clinical study assessing the efficacy of a novel influenza vaccine, aiming to discover distinct, highly predictive patterns of pre-symptomatic illness based on changes in advanced physiological parameters using a novel wearable sensor. Participants were frequently monitored 24 h before and for nine days after the influenza challenge.

View Article and Find Full Text PDF

COVID-19 exerts deleterious cardiopulmonary effects, leading to a worse prognosis in the most affected. This retrospective multi-center observational cohort study aimed to analyze the trajectories of key vitals amongst hospitalized COVID-19 patients using a chest-patch wearable providing continuous remote patient monitoring of numerous vital signs. The study was conducted in five COVID-19 isolation units.

View Article and Find Full Text PDF

A variety of mathematical models of the cardiovascular system have been suggested over several years in order to describe the time-course of a series of physiological variables (i.e. heart rate, cardiac output, arterial pressure) relevant for the compensation mechanisms to perturbations, such as severe haemorrhage.

View Article and Find Full Text PDF

Continuous blood pressure (BP) measurement in intensive care units is based on arterial line (AL) transducers, sometimes associated with clinical complications. Our objective was to evaluate continuous BP measurements obtained from a non-invasive, wireless photoplethysmography (PPG)-based device using two distinct configurations (wristwatch and chest-patch monitors) compared to an AL. In this prospective evaluation study, comparison of the PPG-based devices to the AL was conducted in 10 patients immediately following cardiac surgery.

View Article and Find Full Text PDF