Publications by authors named "Egor Khomenko"

The aim of this paper is to evaluate the effect of pulmonary vein (PV) morphometric characteristics and spatial orientation on the results of cryoballoon ablation (CBA). Methods: A randomized, prospective, single-center controlled study was conducted, enrolling 230 patients with drug-refractory atrial fibrillation (AF). We compared procedural and long-term outcomes in patients who underwent their first procedure of pulmonary vein isolation (PVI) for AF with either radiofrequency ablation (RFA) (n = 108) or CBA (n = 122) and assessed their interaction with the different pattern of PV anatomy, morphometric characteristics, and spatial orientation.

View Article and Find Full Text PDF

Objective: The objective of the study was to estimate the efficacy of a noninvasive ambulatory ECG monitoring (NIAM) in comparison with implantable loop recorder (ILR) in patients with atrial fibrillation (AF).

Methods: Thirty-two patients 58 [47; 73] years of age with AF were included in the study. Patients were randomized into two groups: in group I (n = 15), "Reveal XT" ILR was used for invasive ECG monitoring up to 3 months; in group II (n = 17), "Spyder" device was used for NIAM up to 14 days.

View Article and Find Full Text PDF

Background And Objective: Pulmonary vein (PV) sleeves are established as the main substrate taking part in the mechanisms of atrial fibrillation (AF) initiation. However, we have extremely few data concerning their physiological role in the heart contractility. The aim of the study was to estimate the mechanical function of the left atrium (LA) and PV sleeves before and early after their isolation.

View Article and Find Full Text PDF

Background: Patients with mitral valve (MV) disease and atrial fibrillation (AF) undergo simultaneous prosthetic valve replacement and radiofrequency (RF) ablation procedure; however, this combinational procedure restores sinus rhythm (SR) in only 68-82% of the cases. In patients with ineffective surgical ablation, the use of a biological prosthetic valve might not only be a good choice to perform safe catheter ablation procedure in the left atrium (LA), but also provide a way to discontinue administration of oral anticoagulants. The objective of this study was to assess the efficacy of catheter ablation for AF after MV replacement with a biological prosthesis and an ineffective surgical ablation procedure.

View Article and Find Full Text PDF

Unlabelled: The aim of the study was to compare the efficacy of pulmonary vein antrum isolation (PVAI), extended PVAI and ganglionic plexi (GP) ablation in persistent AF.

Methods: One hundred and twenty patients 56.2 ± 8.

View Article and Find Full Text PDF