Publications by authors named "Edwin Roozen"

Objectives: More effective lung sealants are needed to prevent prolonged pulmonary air leakage (AL). Polyoxazoline-impregnated gelatin patch (N-hydroxysuccinimide ester functionalized poly(2-oxazoline)s; NHS-POx) was promising for lung sealing ex vivo. The aim of this study is to confirm sealing effectiveness in an in vivo model of lung injury.

View Article and Find Full Text PDF

Background: No validated and standardized animal models of pulmonary air leakage (PAL) exist for testing aerostatic efficacy of lung sealants. Lack of negative control groups in published studies and intrinsic sealing mechanisms of healthy animal lungs might contribute to a translational gap, leading to poor clinical results. This study aims to address the impact of intrinsic sealing mechanisms on the validity of PAL models, and investigate the conditions required for an ovine model of PAL for lung sealant testing.

View Article and Find Full Text PDF

Background: The management of bleeding is paramount to any surgical procedure. With the increased use of less invasive laparoscopic and robotic methods, achieving hemostasis can be challenging since the surgeons cannot manually apply hemostatic agents directly onto bleeding tissue. In this study, we assessed the use of a pliable hemostatic sealant patch comprising fibrous gelatin carrier impregnated with poly(2-oxazoline) (NHS-POx) for hemostasis in robotic liver resection in a porcine bleeding model.

View Article and Find Full Text PDF

Background: Sealants are used to prevent prolonged pulmonary air leakage (PAL) after lung resections (incidence 5.6-30%). However, clinical evidence to support sealant use is insufficient, with an unmet need for a more effective product.

View Article and Find Full Text PDF

Background: A new hemostatic sealant based on a N-hydroxy-succinimide polyoxazoline (NHS-POx) polymer was evaluated to determine hemostatic efficacy and long-term wound healing and adverse effects in a large animal model of parenchymal organ surgical bleeds.

Methods: Experiment 1 included 20 pigs that were treated with two NHS-POx patch prototypes [a gelatin fibrous carrier (GFC) with NHS-POx and an oxidized regenerated cellulose (ORC) with poly(lactic-co-glycolic acid)-NHS-POx:NU-POx (nucleophilically activated polyoxazoline)], a blank gelatin patch (GFC Blank), TachoSil and Veriset™ to stop moderate liver and spleen punch bleedings. After various survival periods (1-6 weeks), pigs were re-operated to evaluate patch degradation and parenchymal healing.

View Article and Find Full Text PDF

Background: A translational ex vivo perfusion-based mandibular pig model was developed as an alternative to animal experiments, for initial assessment of biomaterials in dental and maxillofacial surgery and training. This study aimed to assess the face and content validity of the novel perfusion-based model.

Methods: Cadaveric porcine heads were connected to an organ assist perfusion device for blood circulation and tissue oxygenation.

View Article and Find Full Text PDF

Introduction: We developed a novel normothermic ex vivo porcine liver perfusion model with whole blood in order to have alternatives for animal experiments in the research and development of new local haemostatic agents. This study aims to assess the construct and content validity of this model.

Methods: In this study we performed two ex vivo experiments using nine livers and one in vivo experiment using six female Norsvin Topigs pigs: (1) ex vivo liver perfusion for establishing physiological blood parameters of the perfused liver and controlled heparinization, (2) ex vivo liver perfusion with a surgical injury and (3) a surgical liver injury in anaesthetized pigs with and without heparin.

View Article and Find Full Text PDF

In robot-assisted partial nephrectomy (RAPN) renorrhaphy is used to achieve hemostatic control of the tumoral resection bed, with detrimental impact on renal function. Hemostatic agents are used to achieve rapid and optimal hemostasis. GATT-Patch is a new hemostatic sealant that has already demonstrated promising results.

View Article and Find Full Text PDF

A new cost-effective NHS functionalized polyoxazoline (POx) loaded polymer with strong hemostatic properties has been developed. In this study, we investigate POx loaded hemostatic patches regarding hemostatic efficacy, local inflammatory reaction and wound-healing, as compared to the non-POx treated blanks and commercially available hemostatic products. Hundred and ten rats divided into 11 groups of 10 animals underwent partial liver lobe resection.

View Article and Find Full Text PDF

In order to prevent hemorrhage during surgical procedures, a wide range of hemostatic agents have been developed. However, their efficacy is variable; hemostatic devices that use bioactive components to accelerate coagulation are dependent on natural sources, which limits reproducibility. Hybrid devices in which chain-end reactive poly(ethylene glycol) is employed as active component sometimes suffer from irregular cross-linking and dissolution of the polar PEG when blood flow is substantial.

View Article and Find Full Text PDF

Unlabelled: Tubular collagen scaffolds have been used for the repair of damaged hollow organs in regenerative medicine, but they generally lack the ability to reversibly expand in radial direction, a physiological characteristic seen in many native tubular organs. In this study, tubular collagen scaffolds were prepared that display a shape recovery effect and therefore exhibit radial elasticity. Scaffolds were constructed by compression of fibrillar collagen around a star-shaped mandrel, mimicking folds in a lumen, a typical characteristic of empty tubular hollow organs, such as ureter or urethra.

View Article and Find Full Text PDF