Publications by authors named "Edwin A Burgstaler"

Purpose: We have used a hematopoietic progenitor cell (HPC) algorithm (standard [STD]) that restricted the inlet flow rate to 65 mL/min for peripheral white blood cell count (PWBC) >35 × 10 /L (STD). In this study, we evaluated a technique that allows 85 mL/min, regardless of the PWBC count (high). For patients with PWBC >35 × 10 /L, a prospective, randomized comparison of the high flow rate vs the STD PWBC-based flow rate (65 mL/min) was performed, comparing CD34+ and lymphocyte yields, collection efficiencies (CE1), mononuclear cells (MNC), and granulocytes, red blood cell (RBC), and platelet content.

View Article and Find Full Text PDF

Our group published a double phase III trial showing that patients infused with an autograft absolute lymphocyte count (A-ALC) ≥0.5 × 10 cells/kg experienced superior survival post-autologous peripheral blood hematopoietic stem cell transplantation (APBHSCT). Based on the results from our phase III study, as well as published retrospective studies, on April 1, 2017, our Bone Marrow Transplant Program changed our standard practice to collect an A-ALC ≥0.

View Article and Find Full Text PDF

Purpose: Terumo BCT Spectra Optia (O) and Fenwal Amicus (A) can perform therapeutic plasma exchange (TPE). We compared these systems in a prospective, randomized, crossover study of 81 paired procedures. Primary objective was to determine if there was a difference in platelet loss between the instruments.

View Article and Find Full Text PDF

Thyroid storm or severe thyrotoxicosis results from extreme thyroid hormone elevation. Therapy includes medical management to prevent hormone production, release, recycling, and peripheral conversion while stabilizing adrenergic tone. Thyroid dysfunction is the usual cause but it can be due to excessive thyroid hormone ingestion.

View Article and Find Full Text PDF

The Fenwal Alyx for collecting double red cell products has two red cell volume collection settings: fixed collection target of 360 ml (180 ml/unit) and a variable target of collecting either 400 or 360 ml (200 or 180 ml/unit), where the machine aims for the higher possible collection target. We retrospectively compared the two collection targets for the RBC content, donor time, technician time, and collection efficiency. We compared 18 fixed (F) target collections to 40 variable (V) target collections.

View Article and Find Full Text PDF

Background: We compared three instruments for double red blood cell (DRBC) collection to efficiently optimize our RBC inventory.

Study Design And Methods: Instruments compared were the TerumoBCT Trima Accel (Trima), the Fenwal Alyx (Alyx), and the Haemonetics MCS+ 8150 (MCS+). Forty consecutive collections (80 products) per instrument were evaluated for hemoglobin (Hb) content, leukoreduction, collection time, instrument efficiency, donor acceptance, and reactions.

View Article and Find Full Text PDF

Retrospective studies have reported that the collected and infused autograft absolute lymphocyte count (A-ALC) affects clinical outcomes after autologous peripheral hematopoietic stem cell transplantation (APHSCT). We hypothesized that manipulation of the apheresis machine to target a higher A-ALC dose would translate into prolonged progression-free survival (PFS) in patients with non-Hodgkin lymphoma (NHL) undergoing APHSCT. Between December 2007 and October 2010, we performed a double-blind, phase III, randomized study randomly assigning 122 patients with NHL to undergo collection with the Fenwal Amicus Apheresis system with our standard settings (mononuclear cells offset of 1.

View Article and Find Full Text PDF

Background: The AMICUS (Fenwal, Inc.) was cleared in the United States for platelet (PLT) and plasma collection in 1996 with subsequent clearances for the collection of other blood products. Although not previously used for therapeutic plasma exchange (TPE), new disposables, software, and hardware were developed to enable TPE on the AMICUS.

View Article and Find Full Text PDF

To address concerns about infused fluid volume during HPC collections in patients with AL amyloidosis, our institution has used a 26:1 anticoagulant (AC) ratio on the COBE Spectra and on the Fenwal Amicus. In this study, in a cohort of AL amyloid patients, we compared the Amicus version 3.1 to the Spectra version 7 MNC collections with regard to infused fluid volume, CD34+ cell yield, lymphocyte yield, cross-cellular content, and adverse reactions.

View Article and Find Full Text PDF

A technique was developed to improve consistency of MNC transfers from the centrifuge to the collection bag in the Fenwal Amicus. The operator assures that RBCs completely fill the cassette by the end of the transfer by adjusting the RBC offset in succeeding cycles. We compared yields and crosscellular content before and after implementation of the monitoring technique.

View Article and Find Full Text PDF

Introduction: Autologous HPC collection focus has been CD34+ cell yield but product content of other cells is important for patient survival, complications, and resource utilization.

Methods: Prospective, paired study examining MNC and RBC offsets (opens and closes collect valve, respectively) was performed using Fenwal Amicus. Lymphocyte, CD34+ cell yields, and cross-cellular contamination were compared using different MNC/RBC offsets and retrospective Spectra data.

View Article and Find Full Text PDF

Introduction: Bacterial culturing of apheresis platelet (PLT) units appeared to increase the incidence of low yield products of <3.0 x 10(11) PLT (LYP) and decrease the incidence of multiple PLT products. To determine the effects of sampling and subsequent modifications in collections on PLT yield and adverse reactions, a retrospective analysis was performed.

View Article and Find Full Text PDF

Background: Concerned about the effect of multiple platelet (PLT) product donation on donor health, in 2005 the FDA proposed restrictions limiting the number of PLT products donated in 12 months. This was based on limited published evidence. To provide information on the effect of PLT donation on PLT and lymphocyte (LYM) count, hematologic variables were examined in a group of multiple PLT product donors.

View Article and Find Full Text PDF

Auto-antibodies to myocardial antigens have been implicated in the pathogenesis of chronic dilated cardiomyopathy (DCM). A protein A immunoadsorption affinity column system was used to remove IgG antibodies, particularly IgG3. Two techniques, the standard technique (T-1) used for removal of IgG Factor VIII inhibitors and a technique (T-2) designed to enhance IgG3 removal and address issues in venous access, minimize positive fluid balance, and adverse reactions were compared.

View Article and Find Full Text PDF

Dilated cardiomyopathy (DCM) is a leading cause of end-stage heart failure and cardiac transplantation. Anticardiac antibodies are common and removal of these through immunoadsorption (IA) is associated with improvement in global cardiac function. The effect of IA on regional function and quality of life (QOL) without intravenous immunoglobulin (IVIG) substitution has not been described.

View Article and Find Full Text PDF

Apheresis component collection is a rapidly growing area in the blood collection field. Several instruments with varying capabilities are available. This is a brief review of the equipment available for granulocyte and apheresis component collection and indications for their use.

View Article and Find Full Text PDF

Background: Gambro BCT recently introduced the Trima Accel Version 5 (TR) plateletpheresis machine. Platelet (PLT) yields, collection efficiencies (CEs), numbers of white blood cells (WBCs), and processing times of the TR versus the Amicus (Version 2.51) single-needle (AM) procedures were evaluated by use of a prospective paired comparison.

View Article and Find Full Text PDF

A technique for large volume leukapheresis (LVL) for hematopoietic progenitor cell (HPC) collection using the Fenwal Amicus is presented. It was compared to standard collections (STD) with regard to CD34+ cell yields and cross-cellular content. Optimal cycle volumes and machine settings were evaluated for LVL procedures.

View Article and Find Full Text PDF